Visual technique for detection of gas–liquid two-phase flow regime in the airlift pump

2011 ◽  
Vol 75 (3-4) ◽  
pp. 327-335 ◽  
Author(s):  
Pedram Hanafizadeh ◽  
Soheil Ghanbarzadeh ◽  
Mohammad Hassan Saidi
1994 ◽  
Vol 59 (12) ◽  
pp. 2595-2603
Author(s):  
Lothar Ebner ◽  
Marie Fialová

Two regions of instabilities in horizontal two-phase flow were detected. The first was found in the transition from slug to annular flow, the second between stratified and slug flow. The existence of oscillations between the slug and annular flows can explain the differences in the limitation of the slug flow in flow regime maps proposed by different authors. Coexistence of these two regimes is similar to bistable behaviour of some differential equation solutions.


Fluids ◽  
2021 ◽  
Vol 6 (6) ◽  
pp. 226
Author(s):  
Rashal Abed ◽  
Mohamed M. Hussein ◽  
Wael H. Ahmed ◽  
Sherif Abdou

Airlift pumps can be used in the aquaculture industry to provide aeration while concurrently moving water utilizing the dynamics of two-phase flow in the pump riser. The oxygen mass transfer that occurs from the injected compressed air to the water in the aquaculture systems can be experimentally investigated to determine the pump aeration capabilities. The objective of this study is to evaluate the effects of various airflow rates as well as the injection methods on the oxygen transfer rate within a dual injector airlift pump system. Experiments were conducted using an airlift pump connected to a vertical pump riser within a recirculating system. Both two-phase flow patterns and the void fraction measurements were used to evaluate the dissolved oxygen mass transfer mechanism through the airlift pump. A dissolved oxygen (DO) sensor was used to determine the DO levels within the airlift pumping system at different operating conditions required by the pump. Flow visualization imaging and particle image velocimetry (PIV) measurements were performed in order to better understand the effects of the two-phase flow patterns on the aeration performance. It was found that the radial injection method reached the saturation point faster at lower airflow rates, whereas the axial method performed better as the airflow rates were increased. The standard oxygen transfer rate (SOTR) and standard aeration efficiency (SAE) were calculated and were found to strongly depend on the injection method as well as the two-phase flow patterns in the pump riser.


2003 ◽  
Vol 125 (4) ◽  
pp. 544-544 ◽  
Author(s):  
Sang Young Son ◽  
Jeffrey S. Allen ◽  
Kenneth O. Kihm

2011 ◽  
Vol 32 (1) ◽  
pp. 164-175 ◽  
Author(s):  
J. Enrique Julia ◽  
Basar Ozar ◽  
Jae-Jun Jeong ◽  
Takashi Hibiki ◽  
Mamoru Ishii

Sign in / Sign up

Export Citation Format

Share Document