Comparison of the experimental evaluation of a solar intermittent refrigeration system for ice production operating with the mixtures NH3/LiNO3 and NH3/LiNO3/H2O

2012 ◽  
Vol 38 (1) ◽  
pp. 62-68 ◽  
Author(s):  
G. Moreno-Quintanar ◽  
W. Rivera ◽  
R. Best
2017 ◽  
Vol 111 ◽  
pp. 1487-1492 ◽  
Author(s):  
Adriano Akel Vasconcelos ◽  
Abdul Orlando Cárdenas Gómez ◽  
Enio Pedone Bandarra Filho ◽  
José Alberto Reis Parise

2019 ◽  
Vol 11 (12) ◽  
pp. 3346
Author(s):  
João M. Garcia ◽  
Armando Rosa

This article is dedicated to the design, calculation and dimensioning of a small powered refrigeration system (132W) which produces ice bars (freezing) using solar thermal power, and resorts to an intermittent cycle absorption circuit with a water-ammonia mixture (H2O-NH3). The aim of this equipment is to minimize problems faced in places where there is no electric network to supply traditional refrigeration systems which preserve perishable products produced or stocked there, as well as drugs (vaccines), namely for specific regions of developing countries. The system developed can be divided into two parts. The intermittent cycle absorption refrigeration system uses a binary water-ammonia solution (H2O-NH3), where water is the absorber and the ammonia is the coolant and the thermal solar system. This is made up of CPC flat plate thermal collectors or vacuum tubes in which solar energy heats the water that circulates in the primary circuit. In the absorption circulation system, circulation occurs in a natural way due to the fluids affinity, and the temperature and pressure internal variations. This article shows the assumptions underlying the conception, calculation and dimensioning of the system’s construction.


Solar Energy ◽  
2011 ◽  
Vol 85 (1) ◽  
pp. 38-45 ◽  
Author(s):  
W. Rivera ◽  
G. Moreno-Quintanar ◽  
C.O. Rivera ◽  
R. Best ◽  
F. Martínez

Author(s):  
Rasheed Ayofe Shittu ◽  
Isaac Femi Titiladunayo

Aims: This study investigates the performance of a developed automated ice-cube making machine under controlled ambient conditions, in which its energy usage, rate of ice cube production and refrigeration system performance was analysed. Study Design: Average ambient temperatures of 24°C and 32°C were considered for investigation in order to determine their influence on ice production capacity, rate of ice-cube making and energy consumption. The choice of the ambient temperature is based on the extreme ambient conditions under which the machine is designed to operate in a wide range of geographical regions. The refrigeration system performance was carried out under normal room temperature (average of 23°C). Place and Duration of Study: Department of Mechanical Engineering, Federal University of Technology Akure, Ondo State Central Workshop, Between December 2017 and January 2018. Methodology: The machine was set into operation for 5 consecutive ice production cycle during which the ice making time, harvest time, quantity of ice produced and energy consumption were recorded. Results: The ice production capacity, harvesting time and energy consumption show various dissimilarities at both temperatures. 0.618 kg of ice cubes were produced within an ice making cycle of 34.9 minutes, harvesting time of 1.28 minutes and total energy consumption of 0.14053 kWh at 24°C while at 32°C, the machine produced an average of 0.612 kg ice cubes within an ice making cycle of 38.5 minutes harvesting time 1.21 minutes and energy consumption of 0.15947 kWh respectively. Consequently, 13.5% more energy is consumed, with about 1% less quantity of ice produced at 32°C than at 24°C per ice production cycle. Conclusion: Therefore, the ice making capacity of the developed machine suggests that the temperature of the environment has a strong influence on the energy consumption, but little effect on the quantity of ice produced per cycle. The refrigeration system cycle performance analysis results showed a considerably high cooling capacity of 0.379 kW during the ice-making cycle with a corresponding coefficient of performance (COP) of 2.23, and a heating capacity of 2.24 kW during the harvest cycle with a corresponding COP of 8.21. The results obtained showed that the machine is reliable in operation with minimal energy consumption.