Modal analysis and damage detection by Fiber Bragg grating sensors

2007 ◽  
Vol 133 (2) ◽  
pp. 415-424 ◽  
Author(s):  
P. Capoluongo ◽  
C. Ambrosino ◽  
S. Campopiano ◽  
A. Cutolo ◽  
M. Giordano ◽  
...  
2006 ◽  
Vol 6 (1) ◽  
pp. 67-77 ◽  
Author(s):  
A. Cusano ◽  
P. Capoluongo ◽  
S. Campopiano ◽  
A. Cutolo ◽  
M. Giordano ◽  
...  

Author(s):  
Fábio Luis Marques dos Santos ◽  
Bart Peeters ◽  
Ludo Gielen ◽  
Wim Desmet ◽  
Luiz Carlos Sandoval Góes

Sensors ◽  
2019 ◽  
Vol 19 (8) ◽  
pp. 1840
Author(s):  
Sheng Shen ◽  
Huaxin Lv ◽  
Sheng-Lan Ma

It is difficult to detect and evaluate the structural damage in a shield tunnel during operation because many traditional techniques based on the observation of vibrations are limited in daily monitoring in tunnels. Thus, the curvature radius of a static longitudinal settlement curve is used to identify the residual health and safety of an in-service shield tunnel. However, there are still two problems. The curvature radius is suitable for a qualitative judgment rather than a quantitative evaluation for longitudinal damage detection. Moreover, the curvature radius, which is calculated from the measured settlements of three neighboring points, gives an average damage degree in a wide scope only and is difficult to use to identify the damage’s precise location. By means of the analysis of three kinds of longitudinal failure modes in a shield tunnel, this paper proposes: (1) a damage detection method based on the monitored increment of the neutral axis depth; and (2) an index to evaluate longitudinal damage. The index is composed of the residual ratios of the equivalent flexural stiffness (HFM1) and the equivalent shear stiffness (HFM3). The neutral axis position and the proposed damage index can be determined using long-gauge Fiber Bragg Grating sensors. Results from numerical simulations show that the deviation between the HFM1 and the true value residual ratio of the equivalent flexural stiffness is no more than 1.7%. The HFM3 is equal to its true value in the entire damage process. A loading experiment for a scaled-down model of a shield tunnel using long-gauge Fiber Bragg Grating sensors indicated that the errors in the HFM1 were no more than 5.0% in the case of early damage development (HFM1 ≥ 0.5). The maximum error did not exceed 9.0% even under severe damage conditions in the model. Meanwhile, the HFM3 also coincided with its true value in the entire testing process.


Sign in / Sign up

Export Citation Format

Share Document