bragg grating
Recently Published Documents


TOTAL DOCUMENTS

9683
(FIVE YEARS 1477)

H-INDEX

93
(FIVE YEARS 11)

2022 ◽  
Vol 26 ◽  
pp. 101289
Author(s):  
Tamara Pogosian ◽  
Tatiana Statsenko ◽  
Alina Mukhtudinova ◽  
Mikhail Masharin ◽  
Daria Bugakova ◽  
...  
Keyword(s):  

2022 ◽  
Vol 146 ◽  
pp. 107576
Author(s):  
Yu Zheng ◽  
Jiangtao Yue ◽  
Pan Zhang ◽  
Ji'an Duan

2022 ◽  
Vol 12 (2) ◽  
pp. 886
Author(s):  
Hun-Kook Choi ◽  
Young-Jun Jung ◽  
Bong-Ahn Yu ◽  
Jae-Hee Sung ◽  
Ik-Bu Sohn ◽  
...  

This paper demonstrates the fabrication of radiation-resistant fiber Bragg grating (FBG) sensors using infrared femtosecond laser irradiation. FBG sensors were written inside acrylate-coated fluorine-doped single-mode specialty optical fibers. We detected the Bragg resonance at 1542 nm. By controlling the irradiation conditions, we improved the signal strength coming out from the FBG sensors. A significant reduction in the Bragg wavelength shift was detected in the fabricated FBG sensors for a radiation dose up to 105 gray, indicating excellent radiation resistance capabilities. We also characterized the temperature sensitivity of the radiation-resistant FBG sensors and detected outstanding performance.


Sensors ◽  
2022 ◽  
Vol 22 (2) ◽  
pp. 416
Author(s):  
Yang Yu ◽  
Bo Liu ◽  
Feng Xia

A four-loop shaped structure of fiber Bragg grating (FBG) acoustic emission (AE) sensor based on additive manufacturing (AM) technology is proposed in the letter. The finite element analysis (FEA) method was used to model and analyze the sensor structure. We aimed at improving the sensitivity, the static load analysis, and the dynamic response analysis of the normal FBG acoustic emission sensor and the FBG AE sensor with improved structure parameters. We constructed the FBG AE sensor experimental system based on a narrowband laser demodulation method and test on real acoustic emission signals. The results demonstrated that the response sensitivity of the FBG acoustic emission sensor was 1.47 times higher than the sensitivity of the normal FBG sensor. The sensitivity coefficient of PLA-AE-FBG2 sensor was 3.057, and that of PLA-AE-FBG1 was 2.0702. Through structural design and parameter optimization, the sensitivity and stability of the FBG AE sensor are improved. The four-loop shaped sensor is more suitable for the health monitoring in fields such as aero-engine blade, micro-crack of structure, and crack growth in bonded joints. While ensuring the sensing characteristics, sensitivity, and stability of the four-loop shaped sensor have been enhanced. It is possible to apply the FBG AE sensor in some complex engineering environments.


2022 ◽  
Author(s):  
Neha Yadav ◽  
Karol Wachtarczyk ◽  
Paweł Gąsior ◽  
Ralf Schledjewski ◽  
Jerzy Kaleta

2022 ◽  
Author(s):  
Xunzhou Xiao ◽  
Baijie Xu ◽  
Xizhen Xu ◽  
Bin Du ◽  
Ziyong Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document