An indirect method to measure the variation of elastic constant c33 of piezoelectric ceramics shunted to circuit under thickness mode

2014 ◽  
Vol 218 ◽  
pp. 105-115 ◽  
Author(s):  
Yang Sun ◽  
Zhaohui Li ◽  
Qihu Li
2020 ◽  
Vol 46 (8) ◽  
pp. 11913-11920 ◽  
Author(s):  
Jushan Wang ◽  
Junjie Xiao ◽  
Xiangyong Zhao ◽  
Feifei Wang ◽  
Yanxue Tang ◽  
...  

2005 ◽  
Vol 2 (10) ◽  
pp. 3806-3810 ◽  
Author(s):  
María D. Durruthy-Rodríguez ◽  
Lino Borroto-Rivero ◽  
Danny Rodríguez ◽  
Eduardo Moreno-Hernández ◽  
Leslie D. Pérez-Fernández ◽  
...  

1972 ◽  
Vol 33 (C2) ◽  
pp. C2-243-C2-245
Author(s):  
V. V. KLIMOV ◽  
O. S. DIDKOVSKAJA ◽  
G. E. SAVENKOVA ◽  
Ju. N. VENEVTSEV

2009 ◽  
Vol 53 (3-4) ◽  
pp. 115 ◽  
Author(s):  
Péter Csordás ◽  
András Mersich ◽  
Ákos Jobbágy

2007 ◽  
Vol 107 (2) ◽  
pp. 55-60 ◽  
Author(s):  
Laura Finnegan ◽  
Geoff Hamilton ◽  
Julie Perol ◽  
John Rochford

2010 ◽  
Vol 130 (5) ◽  
pp. 844-851 ◽  
Author(s):  
Yosuke Kurihara ◽  
Kosuke Masuyama ◽  
Testuo Nakamura ◽  
Takeshi Bamba ◽  
Kajiro Watanabe

2011 ◽  
Vol 28 (1) ◽  
pp. 33-48 ◽  
Author(s):  
Oto Hanuš ◽  
Václava Genčurová ◽  
Yunhai Zhang ◽  
Pavel Hering ◽  
Jaroslav Kopecký ◽  
...  

Milk acetone determination by the photometrical method after microdiffusion and via FT infra-red spectroscopyMilk acetone (AC) and betahydroxybutyrate (BHB) are important indicators of the energy metabolism of cows (ketosis occurrence) and an effective method for their determination, with reliable results, is of great importance. The goal of this work was to investigate the infrared method MIR-FT in terms of its calibration for milk AC and to develop a usable procedure. The microdiffusion photometric (485 nm; Spekol 11) method was used with salicylaldehyde as a reference (Re) and mid infrared spectroscopy FT (MIR-FT: Lactoscope FT-IR, Delta; MilkoScan FT 6000, M-Sc) as an indirect method. The acetone addition to milk had no recovery using MIR-FT (Delta). The reference AC set must have acceptable statistics for good MIR-FT calibration (M-Sc) and they were: 10.1 ± 9.74 at a geometric mean of 7.26 mg l-1, and a variation range from 1.98 to 33.66 mg l-1. The AC correlation between Re and MIR-FT (Delta) was low at 0.32 (P>0.05 but the Log AC relationship between Re and MIR-FT (M-Sc) was markedly better at 0.80 (P<0.01). The conversion of >10 mg l-1 as an AC subclinical ketosis limit could be > -0.80 (feedback 0.158 mmol l-1 = 9.25 mg l-1) and > -1.66. This could be important for ketosis monitoring (using M-Sc).


2012 ◽  
Vol 27 (3) ◽  
pp. 271-276
Author(s):  
Cui-Min LU ◽  
Qing-Suo LIU ◽  
Jian-Bo ZUO ◽  
Qing-Chi SUN

Sign in / Sign up

Export Citation Format

Share Document