Epitope mapping and cross-reactivity analysis of the monoclonal antibodies against hexon protein of human adenovirus type 3

2009 ◽  
Vol 146 (1-2) ◽  
pp. 58-65 ◽  
Author(s):  
Hongling Qiu ◽  
Zhichao Zhou ◽  
Kaixia Feng ◽  
Xingui Tian ◽  
Xiao Li ◽  
...  
2015 ◽  
Vol 208 ◽  
pp. 66-72 ◽  
Author(s):  
Xingui Tian ◽  
Minglong Liu ◽  
Xiaobo Su ◽  
Zaixue Jiang ◽  
Qiang Ma ◽  
...  

2013 ◽  
Vol 177 (2) ◽  
pp. 189-193 ◽  
Author(s):  
Xingui Tian ◽  
Chenyang Li ◽  
Chunyan Xue ◽  
Xiao Li ◽  
Zhichao Zhou ◽  
...  

Vaccine ◽  
2009 ◽  
Vol 27 (37) ◽  
pp. 5103-5110 ◽  
Author(s):  
Xiaohui Yuan ◽  
Zhangyi Qu ◽  
Xiaomin Wu ◽  
Yingchen Wang ◽  
Lei Liu ◽  
...  

Gene ◽  
1994 ◽  
Vol 146 (2) ◽  
pp. 257-259 ◽  
Author(s):  
Alain Cuzange ◽  
Jadwiga Chroboczek ◽  
Bernard Jacrot

1988 ◽  
Vol 16 (23) ◽  
pp. 11374-11374 ◽  
Author(s):  
Alain Houde ◽  
Joseph M. Weber

Vaccine ◽  
2009 ◽  
Vol 27 (8) ◽  
pp. 1145-1153 ◽  
Author(s):  
Qiwei Zhang ◽  
Xiaobo Su ◽  
Donald Seto ◽  
Bo-jian Zheng ◽  
Xingui Tian ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-16 ◽  
Author(s):  
Hung V. Trinh ◽  
Jonas Grossmann ◽  
Peter Gehrig ◽  
Bernd Roschitzki ◽  
Ralph Schlapbach ◽  
...  

Both isobaric tags for relative and absolute quantitation (iTRAQ) and label-free methods are widely used for quantitative proteomics. Here, we provide a detailed evaluation of these proteomics approaches based on large datasets from biological samples. iTRAQ-label-based and label-free quantitations were compared using protein lysate samples from noninfected human lung epithelial A549 cells and from cells infected for 24 h with human adenovirus type 3 or type 5. Either iTRAQ-label-based or label-free methods were used, and the resulting samples were analyzed by liquid chromatography (LC) and tandem mass spectrometry (MS/MS). To reduce a possible bias from quantitation software, we applied several software packages for each procedure. ProteinPilot and Scaffold Q+ software were used for iTRAQ-labeled samples, while Progenesis LC-MS and ProgenesisF-T2PQ/T3PQ were employed for label-free analyses. R2 correlation coefficients correlated well between two software packages applied to the same datasets with values between 0.48 and 0.78 for iTRAQ-label-based quantitations and 0.5 and 0.86 for label-free quantitations. Analyses of label-free samples showed higher levels of protein up- or downregulation in comparison to iTRAQ-labeled samples. The concentration differences were further evaluated by Western blotting for four downregulated proteins. These data suggested that the label-free method was more accurate than the iTRAQ method.


Viruses ◽  
2015 ◽  
Vol 7 (10) ◽  
pp. 5632-5642 ◽  
Author(s):  
Xingui Tian ◽  
Qiang Ma ◽  
Zaixue Jiang ◽  
Junfeng Huang ◽  
Qian Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document