Does Vertebral End Plate Morphology Affect Cage Subsidence After Transforaminal Lumbar Interbody Fusion?

2019 ◽  
Vol 130 ◽  
pp. e694-e701
Author(s):  
Qing-shuang Zhou ◽  
Xi Chen ◽  
Liang Xu ◽  
Song Li ◽  
Chang-zhi Du ◽  
...  
2021 ◽  
Vol 15 (1) ◽  
pp. 35-40
Author(s):  
Kyriakos Kitsopoulos ◽  
Bernd Wiedenhoefer ◽  
Stefan Hemmer ◽  
Christoph Fleege ◽  
Mohammad Arabmotlagh ◽  
...  

Background: Compared with static cages, expandable cages for Transforaminal Lumbar Interbody Fusion (TLIF), are thought to require less posterior bony removal and nerve root retraction. They may allow the creation of a greater lordotic angle and lordosis restoration. Objective: This study investigated whether TLIF using an expandable lordotic interbody cage facilitates an improvement in both segmental lordosis and the restoration of intradiscal height. Methods: A total of 32 patients with 40 operated segments underwent TLIF surgery for lumbar degenerative disc disease and were consecutively included in this prospective observational study. Of those patients, 25 received monosegmental treatment, six were treated bisegmentally, and one was treated trisegmentally. All patients were assessed clinically and radiographically preoperatively, as well as one week, six months, and two years postoperatively. Results: Two patients required revision for screw loosening and pseudarthrosis. In four patients, the endplate was violated intraoperatively due to cage placement. Postoperatively, cage subsidence was observed in four patients. Significant improvement in the mean degree of spondylolisthesis was noted at the two-year mark. Mean segmental lordosis improved postoperatively. A significant increase in mean disc height of the treated segment was also found. Overall, with the exception of pain, no significant clinical or radiographic changes were reported between the first postoperative week and the two-year year follow-up mark. The mean pain, functional, and quality of life outcomes improved significantly from the preoperative to postoperative period, with no deterioration between six months and two years. Conclusion: This study demonstrates that favorable outcomes can be achieved by using an expandable titanium cage in TLIF procedures.


2017 ◽  
Vol 11 (2) ◽  
pp. 204-212 ◽  
Author(s):  
Hamid Rahmatullah Bin Abd Razak ◽  
Priyesh Dhoke ◽  
Kae-Sian Tay ◽  
William Yeo ◽  
Wai-Mun Yue

<sec><title>Study Design</title><p>Retrospective review of prospective registry data.</p></sec><sec><title>Purpose</title><p>To determine 5-year clinical and radiological outcomes of single-level instrumented minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) in patients with neurogenic symptoms secondary to spondylolisthesis.</p></sec><sec><title>Overview of Literature</title><p>MIS-TLIF and open approaches have been shown to yield comparable outcomes. This is the first study to assess MIS-TLIF outcomes using the minimal clinically important difference (MCID) criterion.</p></sec><sec><title>Methods</title><p>The outcomes of 56 patients treated by a single surgeon, including the Oswestry disability index (ODI), neurogenic symptom score, short-form 36 questionnaire (SF-36), and visual analog scale (VAS) scores for back pain (BP), and leg pain (LP), were collected prospectively for up to 5 years postoperatively. Radiological outcomes included adjacent segment degeneration, fusion, cage subsidence, and screw loosening rates.</p></sec><sec><title>Results</title><p>Our patients were predominantly female (71.4%) and had a mean age of 53.7±11.3 years and mean body mass index of 25.7±3.7 kg/m<sup>2</sup>. The mean operative time, blood loss, time to ambulation, and hospitalization were 167±49 minutes, 126±107 mL, 1.2±0.4 days, and 2.8±1.1 days, respectively. The mean fluoroscopic time was 58.4±33 seconds, and the mean postoperative intravenous morphine dose was 8±2 mg. Regarding outcomes, postoperative scores improved relative to preoperative scores, and this was sustained across various time points for up to 5 years (<italic>p</italic>&lt;0.001). Improvements in ODI, SF-36, VAS-BP, and VAS-LP all met the MCID criterion. Notably, 5.4% of our patients developed clinically significant adjacent segment disease during follow-up, and 7 minor complications were reported.</p></sec><sec><title>Conclusions</title><p>Single-level instrumented MIS-TLIF is suitable for patients with neurogenic symptoms secondary to lumbar spondylolisthesis and is associated with an acceptable complication rate. Both clinical and radiological outcomes were sustained up to 5 years postoperatively, with many patients achieving an MCID.</p></sec>


Spine ◽  
2020 ◽  
Vol 45 (19) ◽  
pp. E1279-E1285 ◽  
Author(s):  
Yu-Cheng Yao ◽  
Po-Hsin Chou ◽  
Hsi-Hsien Lin ◽  
Shih-Tien Wang ◽  
Chien-Lin Liu ◽  
...  

SICOT-J ◽  
2018 ◽  
Vol 4 ◽  
pp. 24
Author(s):  
Mohamed Elmekaty ◽  
Emad ElMehy ◽  
Peter Försth ◽  
Anna MacDowall ◽  
Ahmed El Elemi ◽  
...  

Introduction: Transforaminal lumbar interbody fusion (TLIF) is used to reconstruct disc height and reduce degenerative deformity in spinal fusion. Patients with osteoporosis are at high risk of TLIF cage subsidence; possibly due to the relatively small footprint compared to anterior interbody devices. Recently, modular TLIF cage with an integral rail and slot system was developed to reduce cage subsidence and allow early rehabilitation. Objective: To study the safety of a modular TLIF device in patients with degenerative disc disorders (DDD) with regard to surgical complications, non-union, and subsidence. Methods: Patients with DDD treated with a modular TLIF cage (Polyetheretherketone (PEEK), VTI interfuse S) were analysed retrospectively with one-year follow-up. Lumbar sagittal parameters were collected preoperatively, postoperatively and at one year follow-up. Cage subsidence, fusion rate, screw loosening and proportion of endplate coverage were assessed in computed tomography scan. Results: 20 patients (age 66 ± 10 years, 65% female, BMI 28 ± 5 kg/m2) with a total of 37 fusion levels were included. 15 patients had degenerative spondylosis and 5 patients had degenerative scoliosis. The cages covered >60% of the vertebral body diameters. Lumbar lordosis angle and segmental disc angle increased from 45.2 ± 14.5 and 7.3 ± 3.6 to 52.7 ± 9.1 and 10.5 ± 3.5 (p =  0.029 and 0.0002) postoperatively for each parameter respectively without loss of correction at one year follow up. One case of deep postoperative infection occurred (5%). No cage subsidence occurred. No non-union or screw loosening occurred. Conclusions: The modular TLIF cage was safe with regard to subsidence and union-rate. It restored and maintained lumbar lordosis angle, segmental disc angle and disc height, which can be attributed to the large footprint of this modular cage.


2021 ◽  
pp. 219256822110003
Author(s):  
Yu-Cheng Yao ◽  
Po-Hsin Chou ◽  
Hsi-Hsien Lin ◽  
Shih-Tien Wang ◽  
Ming-Chau Chang

Study Design: Retrospective case-control study. Objectives: This study aims to present the clinical and radiographical outcomes of the titanium-polyetheretherketone (Ti/PEEK) composite cage compared to those of the standard PEEK cage in patients receiving minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). Methods: Patients receiving 1 level MI-TLIF between October 2015 and October 2017 were included with a minimum of 2-year follow-up. The patients were segregated into 2 groups; Ti/PEEK group and PEEK group. Each patient was propensity-matched using preoperative age, sex, and body mass index. Early fusion rate was evaluated by computed tomography at postoperative 6 months. Clinical outcomes were assessed using the visual analog scale (VAS) and Oswestry Disability Index (ODI) scores. Results: After matching, there were 27 patients included in each group. The demographics, diagnosis, and surgical details were not significantly different between the 2 groups. The 6-month rate was 88.9% in Ti/PEEK group. The fusion rate and cage subsidence rate had no difference between the 2 groups. The complication rate in the Ti/PEEK group was comparable to that in the PEEK group. There was no difference in VAS and ODI scores during a 2-year follow-up period. Conclusions: The use of Ti/PEEK composite cage was as safe and effective as the use of PEEK cage in MI-TLIF. The 6-month fusion rate was 88.9%. Our finding revealed comparable clinical results for surgeons using Ti/PEEK composite cages in MI-TLIF compared to those using the PEEK cage.


Sign in / Sign up

Export Citation Format

Share Document