Antiplatelet therapy and periprocedural risk factor analysis for Pipeline embolization device treatment of unruptured internal carotid artery aneurysms: A retrospective, multicenter analysis

Author(s):  
Hisayuki Hosoo ◽  
Eiichi Ishikawa ◽  
Wataro Tsuruta ◽  
Masayuki Sato ◽  
Yoshiro Ito ◽  
...  
2017 ◽  
Vol 23 (6) ◽  
pp. 614-619 ◽  
Author(s):  
Jeremy J Heit ◽  
Nicholas A Telischak ◽  
Huy M Do ◽  
Robert L Dodd ◽  
Gary K Steinberg ◽  
...  

Background Subarachnoid hemorrhage (SAH) secondary to rupture of a blister aneurysm (BA) results in high morbidity and mortality. Endovascular treatment with the pipeline embolization device (PED) has been described as a new treatment strategy for these lesions. We present the first reported case of PED retraction and foreshortening after treatment of a ruptured internal carotid artery (ICA) BA. Case description A middle-aged patient presented with SAH secondary to ICA BA rupture. The patient was treated with telescoping PED placement across the BA. After 5 days from treatment, the patient developed a new SAH due to re-rupture of the BA. Digital subtraction angiography revealed an increase in caliber of the supraclinoid ICA with associated retraction and foreshortening of the PED that resulted in aneurysm uncovering and growth. Conclusions PED should be oversized during ruptured BA treatment to prevent device retraction and aneurysm regrowth. Frequent imaging follow up after BA treatment with PED is warranted to ensure aneurysm occlusion.


2018 ◽  
Vol 11 (5) ◽  
pp. 485-488 ◽  
Author(s):  
Amit Pujari ◽  
Brian Matthew Howard ◽  
Thomas P Madaelil ◽  
Susana Libhaber Skukalek ◽  
Anil K Roy ◽  
...  

BackgroundThe pipeline embolization device (PED) is approved for the treatment of large aneurysms of the proximal internal carotid artery (ICA). Its off-label application in treating aneurysms located specifically at the ICA terminus (ICA-T) has not been studied.MethodsWe conducted a retrospective chart review of patients from 2011 to 7 treated with PEDs. Out of 365 patients, 10 patients with ICA-T aneurysms were included. Patient demographics, procedural information, follow-up imaging, and clinical assessments were recorded.ResultsMean age was 46.9 years (± 8.8), and 6 (60%) patients were women. The mean maximum diameter of the aneurysms treated was 14.7 mm (± 10.7) and the mean neck diameter was 9.3 mm (± 6.6). Reasons for presentation included six incidental findings, one acute subarachnoid hemorrhage (SAH), and three patients with prior SAH. Kamran–Byrne Occlusion Scale scores for the treated aneurysms were as follows: three class IV (complete obliteration), four class III (<50% filling in both height and width for fusiform aneurysms or residual neck for saccular aneurysms), one class II fusiform aneurysm, 1 class 0 saccular aneurysm (residual aneurysm body), and one not classified due to pipeline thrombosis. Two clinically asymptomatic complications were noted: one patient who had a small distal cortical SAH post PED and one patient whose stent was found to be thrombosed on follow-up angiogram. All patients were seen in follow-up, and no patients were found to have worsening of their pre-procedure modified Rankin Scale score.ConclusionThe PED has potential for treating ICA-T aneurysms not amenable to conventional treatment strategies. Further studies are warranted to confirm the long term outcomes.


2018 ◽  
Vol 25 (1) ◽  
pp. 4-11 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Peter Kan ◽  
Visish Srinivasan ◽  
David E Rex ◽  
Katyucia de Macedo Rodrigues ◽  
...  

Background To evaluate the feasibility and efficacy of the pipeline embolization device in the treatment of unruptured intracranial mirror segment aneurysms. Methods Out of a total of 338 subjects, 14 were identified harboring a total of 32 internal carotid artery mirror segment aneurysms that were treated with the pipeline embolization device and were consecutively enrolled into our study. We collected data on patient demographics, modified Rankin scale (mRS) at admission, aneurysm characteristics, clinical outcome at discharge, 3–9 and at 12–18 months as well as angiography results at follow-up. Results Patients’ mean age was 52.9 years; baseline mRS was 0 in all subjects. Pipeline embolization device placement was successful in all cases. Post-treatment mRS remained 0 in 13/14 patients. One patient experienced a small intraparenchymal hemorrhage and subarachnoid hemorrhage, associated with a frontoparietal infarction resulting in right upper extremity weakness and aphasia (post-treatment mRS 3). His mRS evaluation remained stable at the 3–9-month follow-up. Three to 9-month follow-up angiography (13/14 subjects) showed complete aneurysm occlusion in 24/30 aneurysms (80%), near complete and partial occlusion in three of 30 (10%) aneurysms each. At the 9-month follow-up, one patient experienced a complete occlusion of the anterior temporal artery branch but did not present with any clinical deficits. No mRS changes were encountered over a median 6-month follow-up period. Mid-term follow-up angiography (12–18 months) available in eight of 14 subjects showed complete aneurysm occlusion in all patients. Mild intimal hyperplasia was observed in one patient. Conclusions Flow diversion technology can be used for the treatment of unruptured mirror segment aneurysms in selected patients.


2019 ◽  
Vol 10 (01) ◽  
pp. 142-144 ◽  
Author(s):  
Ching-Jen Chen ◽  
M. Rao Patibandla ◽  
Min S. Park ◽  
M. Yashar Kalani

ABSTRACTDespite the widespread use of the pipeline embolization device (PED), no complete aneurysm regrowth after its placement has been reported in the literature. We report the first case of aneurysm regrowth after the initial follow-up angiography demonstrating near-complete occlusion of the aneurysm and remodeling of the vessel with on-label PED use for a large 20 mm × 24 mm × 22 mm (width × depth × height) cavernous segment internal carotid artery (ICA) aneurysm. The patient was treated with two overlapping PED (4.5 mm × 20 mm and 5 mm × 20 mm). Follow-up angiogram at 4 months after treatment demonstrated remodeling of the ICA with a small residual component measuring approximately 7 mm × 8 mm × 7 mm. However, at 10 months after treatment, there was a complete regrowth of the aneurysm with interval growth, now measuring 25 mm × 28 mm × 18 mm. Despite the high aneurysm occlusion rates reported with the PED, persistent aneurysm filling and aneurysm regrowth, although rare, should not be overlooked.


Sign in / Sign up

Export Citation Format

Share Document