The application of metal artifact reduction (MAR) in CT scans for radiation oncology by monoenergetic extrapolation with a DECT scanner

2015 ◽  
Vol 25 (4) ◽  
pp. 314-325 ◽  
Author(s):  
Andrea Schwahofer ◽  
Esther Bär ◽  
Stefan Kuchenbecker ◽  
J. Günter Grossmann ◽  
Marc Kachelrieß ◽  
...  
2019 ◽  
Vol 27 (2) ◽  
pp. 230949901985117 ◽  
Author(s):  
Ka Yin Gregory Lee ◽  
Hei Man Joyce Cheng ◽  
Chi Yeung Chu ◽  
Chi Wai Annie Tam ◽  
Wai Kuen Kan

2011 ◽  
Vol 38 (6Part15) ◽  
pp. 3555-3555
Author(s):  
H Li ◽  
W Thorstad ◽  
J Garcia Ramirez ◽  
K Moore ◽  
Horald H. Li ◽  
...  

2016 ◽  
Vol 119 ◽  
pp. S442-S443
Author(s):  
L. Rechner ◽  
D. Kovacs ◽  
A. Bangsgaard ◽  
A. Berthelsen ◽  
M. Aznar

2011 ◽  
Vol 21 (7) ◽  
pp. 1424-1429 ◽  
Author(s):  
Fabian Bamberg ◽  
Alexander Dierks ◽  
Konstantin Nikolaou ◽  
Maximilian F. Reiser ◽  
Christoph R. Becker ◽  
...  

2014 ◽  
Vol 41 (12) ◽  
pp. 121710 ◽  
Author(s):  
Jakob Toftegaard ◽  
Walther Fledelius ◽  
Dieter Seghers ◽  
Michael Huber ◽  
Marcus Brehm ◽  
...  

2017 ◽  
Vol 58 (11) ◽  
pp. 1867-1872 ◽  
Author(s):  
Charlotte S. van der Vos ◽  
Anne I.J. Arens ◽  
James J. Hamill ◽  
Christian Hofmann ◽  
Vladimir Y. Panin ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Chena Lee ◽  
Ari Lee ◽  
Yoon Joo Choi ◽  
Kug Jin Jeon ◽  
Young Hyun Kim ◽  
...  

AbstractThis study investigated whether metal artifact reduction (MAR) applied computed tomography (CT) scans could be used to generate precise digital models and explored possible correlations between the amount of metal artifact and model accuracy. Thirty maxillofacial CT scans were randomly selected and a MAR algorithm was applied. By subtracting the original and MAR-applied CT images, the amount of metal artifact was quantified. Digital models were generated from the original and the MAR-applied CT data. Paired digital models were superimposed and shape deviation in planar surface was measured at 10 points in 4 planes. Statistical analyses were performed to compare deviations and to assess correlations between the amount of artifact and deviation. The MAR algorithm reduced metal artifact in all cases. The overall mean deviation of the MAR-applied models was 0.0868 mm, with no significant difference according to the reference plane. The amount of artifact did not significantly influence the accuracy of the digital models. MAR-applied CT is a convenient source for digital modeling with clinically acceptable accuracy. The MAR algorithm can be used regardless of the amount of metal artifact, which are generated by dental prostheses, for the quick and convenient manipulation of dental digital models.


Sign in / Sign up

Export Citation Format

Share Document