The effect of fasting status on the determination of low-density and high-density lipoprotein cholesterol

1995 ◽  
Vol 99 (4) ◽  
pp. 374-377 ◽  
Author(s):  
Lora B. Wilder ◽  
Paul S. Bachorik ◽  
Cheryl A. Finney ◽  
Taryn F. Moy ◽  
Diane M. Becker
1996 ◽  
Vol 42 (3) ◽  
pp. 424-429 ◽  
Author(s):  
M Nauck ◽  
W März ◽  
B Haas ◽  
H Wieland

Abstract We evaluated a new homogeneous assay for quantifying high-density lipoprotein cholesterol (HDL-C). The assay included four reagents: polyethylene glycol for "wrapping" chylomicrons, very-low-density lipoproteins (VLDL), and low-density lipoproteins (LDL); antibodies specific for apolipoprotein (apo) B and apo C-III to produce aggregates of chylomicrons, VLDL, and LDL; enzymes for the enzymatic cholesterol determination of the noncomplexed lipoproteins with 4-aminoantipyrine as the color reagent; and guanidine salt to stop the enzymatic reaction and to solubilize the complexes of apo B-containing lipoproteins, which would otherwise interfere with the reading of absorbance. The total CVs of the new method ranged between 2.4% and 8.4%. The HDL-C values (y) were in good agreement with those by a comparison phosphotungstic acid/MgCl2 method (x): y= 0.987x + 17.2 mg/L (68th percentile of the residuals on the regression line= 21.49, r= 0.970). At triglyceride concentrations of 20 g/L (Intralipid) the homogeneous HDL-C concentrations increased by 2%. Hemoglobin markedly increased the results, whereas bilirubin reduced them. The homogeneous HDL-C assay was easy to handle and allows full automation. This test should considerably facilitate the screening of individuals at an increased risk of cardiovascular disease.


1997 ◽  
Vol 92 (5) ◽  
pp. 473-479 ◽  
Author(s):  
Gregory D. Sloop ◽  
David W. Garber

1. Increased blood or plasma viscosity has been observed in almost all conditions associated with accelerated atherosclerosis. Cognizant of the enlarging body of evidence implicating increased viscosity in atherogenesis, we hypothesize that the effects of low-density lipoprotein and high-density lipoprotein on blood viscosity correlate with their association with risk of atherosclerosis. 2. Blood viscometry was performed on samples from 28 healthy, non-fasting adult volunteers using a capillary viscometer. Data were correlated with haematocrit, fibrinogen, serum viscosity, total cholesterol, high-density lipoprotein-cholesterol, triglycerides and calculated low-density lipoprotein-cholesterol. 3. Low-density lipoprotein-cholesterol was more strongly correlated with blood viscosity than was total cholesterol (r = 0.4149, P = 0.0281, compared with r = 0.2790, P = 0.1505). High-density lipoprotein-cholesterol levels were inversely associated with blood viscosity (r = −0.4018, P = 0.0341). 4. To confirm these effects, viscometry was performed on erythrocytes, suspended in saline, which had been incubated in plasma of various low-density lipoprotein/high-density lipoprotein ratios. Viscosity correlated directly with low-density lipoprotein/high-density lipoprotein ratio (n = 23, r = 0.8561, P < 0.01). 5. Low-density lipoprotein receptor occupancy data suggests that these effects on viscosity are mediated by erythrocyte aggregation. 6. These results demonstrate that the effects of low-density lipoprotein and high-density lipoprotein on blood viscosity in healthy subjects correlate with their association with risk of atherosclerosis. These effects on viscosity may play a role in atherogenesis by modulating the dwell or residence time of atherogenic particles in the vicinity of the endothelium.


1984 ◽  
Vol 30 (1) ◽  
pp. 127-129 ◽  
Author(s):  
N N Rehak ◽  
R J Elin ◽  
R Chesler ◽  
E Johnson

Abstract We compared the Du Pont aca (phosphotungstate-enzymic cholesterol) and the Dow (dextran sulfate/Mg2+-enzymic cholesterol) methods for the determination of high-density lipoprotein cholesterol (HDLC) and total cholesterol in serum from 113 patients. The aca results for both total cholesterol and HDLC were significantly greater (p less than 0.0001) than the Dow results, the aca method overestimating the HDLC concentration (mean recovery 107.2% in serum samples with values assigned by the Centers for Disease Control). The precision of the aca method for HDLC was essentially the same as that of the Dow method. Bilirubin (up to 0.17 g/L), hemoglobin (up to 4 g/L), and slight lipemia (triglycerides up to 5.4 g/L) did not interfere with the aca method.


1979 ◽  
Vol 25 (7) ◽  
pp. 1309-1313 ◽  
Author(s):  
C Mayfield ◽  
G R Warnick ◽  
J J Albers

Abstract Commercial heparin preparations (18 lots) from seven manufacturers were compared in the heparin-Mn2+ procedure for high-density-lipoprotein cholesterol quantitation. With normotriglyceridemic samples, 16 heparin lots, isolated from porcine intestinal mucosa, gave mean values for supernatant cholesterol that did not differ statistically; all were within 7 mg/L. Two heparin preparations from bovine lung gave results that were slightly (16 mg/L, average) but significantly (p less than 0.005) lower. With hypertriglyceridemic samples, we observed greater variation in supernatant cholesterol among the heparin preparations, which was ascribable to variable sedimentation by centrifugation of very-low-density and low-density lipoproteins precipitated by heparin-Mn2+ treatment. If the precipitated lipoproteins were completely removed by an ultrafiltration procedure, we saw no significant difference among the heparin preparations for results with hypertriglyceridemic samples.


Sign in / Sign up

Export Citation Format

Share Document