Accuracy and precision of point-of-care testing for glucose and prothrombin time at the critical care units

2001 ◽  
Vol 307 (1-2) ◽  
pp. 119-123 ◽  
Author(s):  
Cecilia Yuoh ◽  
M Tarek Elghetany ◽  
John R Petersen ◽  
Amin Mohammad ◽  
Anthony O Okorodudu
1995 ◽  
Vol 4 (6) ◽  
pp. 429-434 ◽  
Author(s):  
Lamb LSJr ◽  
RS Parrish ◽  
SF Goran ◽  
MH Biel

BACKGROUND: The development of user-friendly laboratory analyzers, combined with the need for rapid assessment of critically ill patients, has led to the performance of in vitro diagnostic testing at the point of care by personnel without formal laboratory training. OBJECTIVES: To determine the range of laboratory testing performed by critical care nurses and their attitudes toward this role. METHODS: A survey of critical care nursing consultants was conducted, using a modified Likert scale, to assess objective measures of point-of-care testing practice in critical care units and to determine nurses' attitudes toward the practice of point-of-care testing. Statistical analysis was performed to determine significant trends in responses. RESULTS: Of the units responding to the survey, 35% used critical care nurses exclusively to perform point-of-care testing, 32.5% used laboratory technicians and critical care nurses, and 25% used other personnel. Of critical care nurses performing laboratory testing, 95.5% performed blood glucose analysis; 18.7%, arterial blood gas analysis; 4.5%, electrolyte analysis; 4.5%, hematology profiles; and 22.7%, other testing. Most agreed that stat tests were not reported promptly, thereby necessitating bedside testing. Respondents indicated that they would prefer that laboratory personnel operate in vitro diagnostic equipment and that requirements for critical care nurses to perform laboratory testing detracted from other patient care duties. CONCLUSIONS: Most nurses who perform point-of-care testing responded that it was necessary and helpful in patient management. However, they would prefer, because of their other patient care responsibilities, that laboratory personnel take this responsibility.


1999 ◽  
Vol 8 (2) ◽  
pp. 72-83 ◽  
Author(s):  
MA Harvey

BACKGROUND: Critical care practitioners are searching for ways to improve the quality and outcomes of care while decreasing cost and length of stay. One technological advance that may facilitate meeting these objectives is bedside or point-of-care laboratory equipment. Evaluation of point-of-care testing for application in each institution requires information about the devices available; knowledge of the advantages and disadvantages of the technologies, the clinical impact, and cost of the process change; and strategies for successful implementation. OBJECTIVES: To review the literature on point-of-care testing and the experience of healthcare professionals who have already successfully implemented this type of testing. METHODS: A total of 81 relevant published articles were reviewed, and 21 critical care units in 8 facilities that use point-of-care testing were visited. Open-ended interviews were conducted with 83 subjects: 56 nurses, 14 laboratory personnel, 9 respiratory therapists, and 4 others. CONCLUSIONS: Point-of-care testing is a technological innovation with the potential for improving patients' care without increasing costs. It most likely will soon become part of the standard of care.


2016 ◽  
pp. 97-121 ◽  
Author(s):  
S.N. Narla ◽  
M. Jones ◽  
K.L. Hermayer ◽  
Y. Zhu

2021 ◽  
Vol 172 ◽  
pp. 112770
Author(s):  
Nicholas X. Williams ◽  
Brittani Carroll ◽  
Steven G. Noyce ◽  
Hansel Alex Hobbie ◽  
Daniel Y. Joh ◽  
...  

Author(s):  
Nam K. Tran ◽  
Zachary Godwin ◽  
Jennifer Bockhold ◽  
Gerald J. Kost

2018 ◽  
Vol 26 (4) ◽  
pp. 218-224 ◽  
Author(s):  
Jung Hee Han ◽  
Seongsoo Jang ◽  
Mi-Ok Choi ◽  
Mi-Jeong Yoon ◽  
Seung-Bok Lim ◽  
...  

Background: The confirmation of prothrombin time international normalized ratio by a central laboratory often delays intravenous thrombolysis in patients with acute ischemic stroke. Objectives: We investigated the feasibility, reliability, and usefulness of point-of-care determination of prothrombin time international normalized ratio for stroke thrombolysis. Methods: Among 312 patients with ischemic stroke, 202 who arrived at the emergency room within 4.5 h of stroke onset were enrolled in the study. Patients with lost orders for point-of-care testing for the prothrombin time international normalized ratio or central laboratory testing for the prothrombin time international normalized ratio (n = 47) were excluded. We compared international normalized ratio values and the time interval from arrival to the report of test results (door-to-international normalized ratio time) between point-of-care testing for the prothrombin time international normalized ratio and central laboratory testing for the prothrombin time international normalized ratio. In patients who underwent thrombolysis, we compared the time interval from arrival to thrombolysis (door-to-needle time) between the current study population and historic cohort at our center. Results: In the 155 patients included in the study, the median door-to-international normalized ratio time was 9.0 min (interquartile range, 5.0–12.0 min) for point-of-care testing for the prothrombin time international normalized ratio and 46.0 min (interquartile range, 38.0–55.0 min) for central laboratory testing for the prothrombin time international normalized ratio (p < 0.001). The intraclass correlation coefficient between point-of-care testing for the prothrombin time international normalized ratio and central laboratory testing for the prothrombin time international normalized ratio was 0.975 (95% confidence interval: 0.966–0.982). Forty-nine of the 155 patients underwent intravenous thrombolysis. The door-to-needle time was significantly decreased after implementation of point-of-care testing for the prothrombin time international normalized ratio (median, 23.0 min; interquartile range, 16.0–29.8 vs median, 46.0 min; interquartile range, 33.5–50.5 min). Conclusion: Utilization of point-of-care testing for the prothrombin time international normalized ratio was feasible in the management of patients with acute ischemic stroke. Point-of-care testing for the prothrombin time international normalized ratio was quick and reliable and had a pivotal role in expediting thrombolysis.