Nuclear Magnetic Resonance in Laboratory Animals

Author(s):  
A. Heerschap ◽  
M.G. Sommers ◽  
H.J.A.in ‘t Zandt ◽  
W.K.J. Renema ◽  
A.A. Veltien ◽  
...  
1987 ◽  
Vol 7 (2) ◽  
pp. 199-206 ◽  
Author(s):  
David G. Gadian ◽  
Richard S. J. Frackowiak ◽  
H. Alan Crockard ◽  
Edward Proctor ◽  
Kathryn Allen ◽  
...  

CBF has been measured with the hydrogen clearance technique in the two cerebral hemispheres of the gerbil under halothane anaesthesia. This has been correlated with changes in local pH, tissue lactate, and phosphorus energy metabolites measured in the same animals with 1H and 31P nuclear magnetic resonance (NMR) spectroscopy. The NMR measurements were made with two surface coils, one on each hemisphere. This article describes the experimental details and shows that in acute unilateral or bilateral forebrain ischaemia metabolic changes can be monitored by NMR with no significant interhemispheric cross talk. The metabolic effects of reperfusion are also shown. The model allows the definition of the time course of the metabolic consequences of regional ischaemia and reperfusion in individual laboratory animals.


Diagnostics ◽  
2019 ◽  
Vol 9 (4) ◽  
pp. 198 ◽  
Author(s):  
João Pedroso ◽  
João Camporez ◽  
Luciana Belpiede ◽  
Rafaela Pinto ◽  
José Cipolla-Neto ◽  
...  

Devices that analyze body composition of rodents by time-domain nuclear magnetic resonance (TD-NMR) are becoming popular in research centers that study metabolism. Theoretically, TD-NMR devices can also evaluate lipid content in isolated tissues. However, the accuracy of TD-NMR to determine hepatic steatosis in the liver of small laboratory animals has not been evaluated in detail. We observed that TD-NMR was able to detect increased lipid content in the liver of rats consuming high-fat diet (HFD) for 12 weeks and in genetically obese (Lepob/ob and Leprdb/db) mice. The lipid content determined by TD-NMR showed a positive correlation with triglyceride content measured by colorimetric assays. In contrast, TD-NMR did not detect hepatic steatosis in C57BL/6 mice consuming HFD for 4 or 12 weeks, despite their obesity and increased liver triglyceride content. These findings indicate that tissue mass and the severity of hepatic steatosis affect the sensitivity of TD-NMR to detect liver lipid content.


Author(s):  
M.J. Hennessy ◽  
E. Kwok

Much progress in nuclear magnetic resonance microscope has been made in the last few years as a result of improved instrumentation and techniques being made available through basic research in magnetic resonance imaging (MRI) technologies for medicine. Nuclear magnetic resonance (NMR) was first observed in the hydrogen nucleus in water by Bloch, Purcell and Pound over 40 years ago. Today, in medicine, virtually all commercial MRI scans are made of water bound in tissue. This is also true for NMR microscopy, which has focussed mainly on biological applications. The reason water is the favored molecule for NMR is because water is,the most abundant molecule in biology. It is also the most NMR sensitive having the largest nuclear magnetic moment and having reasonable room temperature relaxation times (from 10 ms to 3 sec). The contrast seen in magnetic resonance images is due mostly to distribution of water relaxation times in sample which are extremely sensitive to the local environment.


Author(s):  
Paul C. Lauterbur

Nuclear magnetic resonance imaging can reach microscopic resolution, as was noted many years ago, but the first serious attempt to explore the limits of the possibilities was made by Hedges. Resolution is ultimately limited under most circumstances by the signal-to-noise ratio, which is greater for small radio receiver coils, high magnetic fields and long observation times. The strongest signals in biological applications are obtained from water protons; for the usual magnetic fields used in NMR experiments (2-14 tesla), receiver coils of one to several millimeters in diameter, and observation times of a number of minutes, the volume resolution will be limited to a few hundred or thousand cubic micrometers. The proportions of voxels may be freely chosen within wide limits by varying the details of the imaging procedure. For isotropic resolution, therefore, objects of the order of (10μm) may be distinguished.Because the spatial coordinates are encoded by magnetic field gradients, the NMR resonance frequency differences, which determine the potential spatial resolution, may be made very large. As noted above, however, the corresponding volumes may become too small to give useful signal-to-noise ratios. In the presence of magnetic field gradients there will also be a loss of signal strength and resolution because molecular diffusion causes the coherence of the NMR signal to decay more rapidly than it otherwise would. This phenomenon is especially important in microscopic imaging.


Sign in / Sign up

Export Citation Format

Share Document