One-year Follow-up Results of Combined Mitomycin C Trabeculectomy and E~rtracapsular Cataract Extraction

Ophthalmology ◽  
1995 ◽  
Vol 102 (1) ◽  
pp. 76-83 ◽  
Author(s):  
Karen M. Joos ◽  
Michael J. Bueche ◽  
Paul F. Palmberg ◽  
William J. Feuer ◽  
Alana L. Grajewski
2018 ◽  
Vol 29 (3) ◽  
pp. 309-314 ◽  
Author(s):  
Ana Ibáñez-Muñoz ◽  
Víctor Santiago Soto-Biforcos ◽  
María Chacón-González ◽  
Oscar Rúa-Galisteo ◽  
Alexandra Arrieta-Los Santos ◽  
...  

Purpose: To evaluate the intraocular pressure–lowering effect, the safety profile, and the success rate of the XEN45 Gel Stent (Allergan, Dublin, Ireland) in patients with pseudoexfoliative glaucoma. Methods: Retrospective study conducted on patients with pseudoexfoliative glaucoma, with or without cataract, who underwent XEN45 implantation surgery with subconjunctival mitomycin-C and had a minimum postoperative follow-up period of 12 months. The primary outcome measure was intraocular pressure reduction at 1 year as compared to baseline. Complete success was defined as a postoperative intraocular pressure reduction of ⩾20% from preoperative baseline at 12 months without any glaucoma medications. Qualified success was defined as a postoperative intraocular pressure reduction of ⩾20% at 12 months with medications. Results: Of the 24 screened patients, 21 eyes of 20 patients met the inclusion/exclusion criteria and were included in the study. A total of 13 (62%) eyes underwent XEN alone surgery and 8 (38%) eyes had combined XEN + cataract surgery. Mean intraocular pressure was significantly reduced from 21.1 (3.8) mmHg at baseline to 15.2 (3.9) mmHg at 1 year, p < 0.001. Mean antiglaucoma medications dropped from 2.95 (0.97) preoperatively to 1.23 (1.22) at month 12 (p < 0.001). Of the 21 eyes included in the study, 18 (85.7%) were considered as success, 6 (28.6%) as complete success, and 12 (57.1%) as qualified success. Five eyes required needling revision. Complications included uveitis, choroidal detachment, hyphema, and cystoid macular edema in 2, 1, 1, and 1 eye, respectively. Conclusion: XEN45 Gel Stent implant significantly reduced the intraocular pressure and the number of antiglaucoma medications in patients with pseudoexfoliative glaucoma.


2019 ◽  
Author(s):  
Ehab M. Moawad ◽  
Ahmed A. Abd Elghany ◽  
Amr A. Gab-Alla ◽  
Osama M. Elbassiouny ◽  
Mohsen S. Badawy

Abstract Background The study aimed to assess the role of intraoperative mitomycin-C (MMC) application during hyperopic LASIK correction (+1.00 D to +6.00 D) by examining topographic corneal changes and incidence of regression over a one-year follow-up period. Methods This comparative randomized control study included 136 eyes of 68 hyperopic patients divided into two groups; Group A included 68 eyes of 34 patients that had LASIK with the application of 0.02% MMC for 10 seconds on the stromal bed after excimer laser treatment, and group B included 68 eyes of 34 patients that had LASIK without MMC application. Uncorrected distance visual acuity (UDVA), refraction, keratometry and topography were recorded at 1st week and 1st, 3rd, 6th, and 12th months postoperation. Predictability and treatment efficacy were also recorded at the end of the follow-up period. Results Better predictability was noted in group A than in group B at the 6 month and 12 month follow-up visits, with a mean cycloplegic refraction SE of +0.5 ± 0.31 D in group A and +0.67 ± 0.39 D in group B at the 6 month visit, and +0.63 ± 0.37 D in group A and +0.89 ± 0.48 D in group B at the 12 month visit. The efficacy of the treatment at the end of the follow up period was better in group A than in group B. Group A showed fewer topographic corneal changes than group B. Conclusions Intraoperative MMC application during hyperopic LASIK achieves better predictability and efficacy and induces fewer topographic changes and lower regression rate of hyperopia during the first postoperative year. Trial registration: the Pan African Clinical Trial Registry PACTR201901543722087, on 29 January 2019.


2019 ◽  
Author(s):  
Ehab M. Moawad ◽  
Ahmed A. Abd Elghany ◽  
Amr A. Gab-Alla ◽  
Osama M. Elbassiouny ◽  
Mohsen S. Badawy

Abstract Background The study aimed to assess the role of intraoperative mitomycin-C (MMC) application during hyperopic LASIK correction (+1.00 D to +6.00 D) by examining topographic corneal changes and incidence of regression over a one-year follow-up period. Methods This comparative randomized control study included 136 eyes of 68 hyperopic patients divided into two groups; Group A included 68 eyes of 34 patients that had LASIK with the application of 0.02% MMC for 10 seconds on the stromal bed after excimer laser treatment, and group B included 68 eyes of 34 patients that had LASIK without MMC application. Uncorrected distance visual acuity (UDVA), refraction, keratometry and topography were recorded at 1st week and 1st, 3rd, 6th, and 12th months postoperation. Predictability and treatment efficacy were also recorded at the end of the follow-up period. Results Better predictability was noted in group A than in group B at the 6 month and 12 month follow-up visits, with a mean cycloplegic refraction SE of +0.5 ± 0.31 D in group A and +0.67 ± 0.39 D in group B at the 6 month visit, and +0.63 ± 0.37 D in group A and +0.89 ± 0.48 D in group B at the 12 month visit. The efficacy of the treatment at the end of the follow up period was better in group A than in group B. Group A showed fewer topographic corneal changes than group B. Conclusions Intraoperative MMC application during hyperopic LASIK achieves better predictability and efficacy and induces fewer topographic changes and lower regression rate of hyperopia during the first postoperative year. Trial registration: the Pan African Clinical Trial Registry PACTR201901543722087, on 29 January 2019.


2019 ◽  
Author(s):  
Ehab M. Moawad ◽  
Ahmed A. Abd Elghany ◽  
Amr A. Gab-Alla ◽  
Osama M. Elbassiouny ◽  
Mohsen S. Badawy

Abstract Background The study aimed to assess the role of intraoperative mitomycin-C (MMC) application during hyperopic LASIK correction (+1.00 D to +6.00 D) by examining topographic corneal changes and incidence of regression over a one-year follow-up period. Methods This comparative randomized control study included 136 eyes of 68 hyperopic patients divided into two groups; Group A included 68 eyes of 34 patients that had LASIK with the application of 0.02% MMC for 10 seconds on the stromal bed after excimer laser treatment, and group B included 68 eyes of 34 patients that had LASIK without MMC application. Uncorrected distance visual acuity (UDVA), refraction, keratometry and topography were recorded at 1st week and 1st, 3rd, 6th, and 12th months postoperation. Predictability and treatment efficacy were also recorded at the end of the follow-up period. Results Better predictability was noted in group A than in group B at the 6 month and 12 month follow-up visits, with a mean cycloplegic refraction SE of +0.5 ± 0.31 D in group A and +0.67 ± 0.39 D in group B at the 6 month visit, and +0.63 ± 0.37 D in group A and +0.89 ± 0.48 D in group B at the 12 month visit. The efficacy of the treatment at the end of the follow up period was better in group A than in group B. Group A showed fewer topographic corneal changes than group B. Conclusions Intraoperative MMC application during hyperopic LASIK achieves better predictability and efficacy and induces fewer topographic changes and lower regression rate of hyperopia during the first postoperative year. Trial registration: the Pan African Clinical Trial Registry PACTR201901543722087, on 29 January 2019.


2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
Ahmed Galal ◽  
Alper Bilgic ◽  
Rasha Eltanamly ◽  
Amr Osman

Purpose. To evaluate gel microstent (XEN, Aquesys, Inc) for treatment of primary open angle glaucoma (POAG). Methods. In this prospective interventional study, 13 eyes with POAG underwent XEN implantation with subconjunctival mitomycin-C. Of those eyes, 3 were pseudophakic and 10 underwent simultaneous phacoemulsification and XEN. Patients had uncontrolled IOP, had intolerance to therapy, or had maximal therapy but undergoing cataract extraction. Follow-up visits included IOP, number of medications, vision, and complications and lasted for 1 year. Complete success was defined as IOP reduction ≥20% from preoperative baseline at 1 year without any glaucoma medications while partial success as IOP reduction of ≥20% at 1 year with medications. Results. IOP dropped from 16 ± 4 mmHg pre-op to 9 ± 5, 11 ± 6, 12 ± 5, 12 ± 4, and 12 ± 3 mmHg at 1 week, 1, 3, 6, and 12 months (p=0.004, 0.026, 0.034, 0.01, and 0.01, Wilcoxon Signed Ranks) consecutively. BCVA (LogMAR) was 0.33 ± 0.34 and improved to 0.13 ± 0.11 at 1 year. Mean number of medications dropped from 1.9 ± 1 preoperatively to 0.3 ± 0.49 (p=0.003) at 1 year. 42% of eyes achieved complete success and 66% qualified success. Complications included choroidal detachment in 2 eyes, and implant extrusion in 1 eye, and 2 eyes underwent trabeculectomy. Conclusion. XEN implant is an effective surgical treatment for POAG, with significant reduction in IOP and glaucoma medications at 1 year follow-up.


Author(s):  
Prachi Shukla ◽  
Suman Bhartiya

Introduction: Recurrence is the most common problem with pterygium excision. Various adjunctive methods have been described to decrease the recurrence rate of pterygium. Mitomycin C (MMC) and limbal Conjunctival Autograft (CAG) are most commonly used methods to reduce its recurrence. Aim: To compare the recurrence rate of pterygium and the complications with MMC eyedrops after bare sclera pterygium excision versus sutureless and glue free CAG. Materials and Methods: Total 104 eyes were divided into two groups (A and B) of 52 eyes each. Group A patients underwent bare sclera excision of pterygium followed by 0.01% MMC eye drops BD (twice a day) for five days and Group B patients had sutureless and glue free CAG using oozing blood as tissue adhesive after pterygium excision. The patients were followed-up postoperatively on day 1, day 3, day 7, one month, three months, six months and one year. All the patients were examined for recurrence and complications. Statistical analysis was done by using Statistical Package for the Social Sciences (SPSS) version 16 and student’s t-test was applied for comparison. Results: A total of 104 eyes of 92 patients were divided into two groups (A and B) of 52 each. The mean age of Group A was around 45 year and group B was around 43 years and the difference was statistically insignificant (p>0.05). Total three patients had recurrence in one year of follow-up in group A, out of which first case appeared before the end of 1st month, second before the completion of 3rd month and the third case at the last follow-up. In group B only one case presented with recurrence at 6th month follow-up. The difference between the recurrences in both the groups was statistically insignificant (p>0.05). Short term complications were observed in five patients in group A. One patient had corneal thinning; one had scleral thinning, two patients presented with avascular sclera and one patient with granuloma. In group B, 18 patients with graft retraction, eight with graft oedema, five with sub-conjunctival graft haemorrhage and one with granuloma were observed. All these complications resolved by the time. Long term complications were not observed in any patient of both the groups. Conclusion: This study concluded that the use of MMC eye drops (0.01%) BD or glue free and sutureless CAG after pterygium excision is safe and effective treatment modalities for pterygium.


2016 ◽  
Vol 7 (3) ◽  
pp. 548-554 ◽  
Author(s):  
Bonnie Nga Kwan Choy ◽  
Mandy Oi Man Wong ◽  
Jonathan Cheuk Hung Chan ◽  
Connie Hong Yee Lai ◽  
Jimmy Shiu Ming Lai

This case report illustrates the use of ExPRESS mini-shunt in a pediatric glaucoma patient. We describe the management of steroid-induced glaucoma with ExPRESS mini-shunt in a 9-year-old boy with allergic keratoconjunctivitis. The intraocular pressure of both of his eyes was uncontrolled with medical and laser treatment. Both eyes were treated with ExPRESS mini-shunt and mitomycin-C. Transient overfiltration with postoperative hypotony occurred in both eyes and resolved after 2 weeks. One year postoperatively, intraocular pressure was maintained below 21 mm Hg without medication in 1 eye. Bleb needling with mitomycin-C was done to maintain filtration. The fellow eye received cataract extraction but developed bleb failure a few months afterwards. The intraocular pressure was controlled medically. To conclude, ExPRESS mini-shunt is a new surgical option in selected patients. Bleb failure developed after cataract extraction. Postoperative inflammation should be minimized. Patient selection, such as those with stable ocular condition, is important to increase surgical success.


Sign in / Sign up

Export Citation Format

Share Document