Gliding resistance after repair of partially lacerated human flexor digitorum profundus tendon in vitro

2001 ◽  
Vol 16 (8) ◽  
pp. 696-701 ◽  
Author(s):  
Chunfeng Zhao ◽  
Peter C. Amadio ◽  
Mark E. Zobitz ◽  
Toshimitsu Momose ◽  
Paulus Couvreur ◽  
...  
2005 ◽  
Vol 30 (3) ◽  
pp. 288-293 ◽  
Author(s):  
N. KUSANO ◽  
M. A. ZAEGEL ◽  
J. D. PLACZEK ◽  
R. H. GELBERMAN ◽  
M. J. SILVA

We evaluated the effects of two types of supplementary core sutures on the tensile properties and resistance to gap formation of flexor digitorum profundus (FDP) tendon-bone repairs. Forty-five human cadaver FDP tendons were sharply released from their insertion sites and repaired to bone utilizing one of three repair techniques: four-strand modified Becker core suture (Becker only), modified Becker plus a figure-of-eight supplementary core suture (Becker plus figure-of-eight), and modified Becker plus a supplementary core suture using a bone anchor (Becker plus anchor). Ultimate (maximum) force did not differ between repair groups. However, addition of a supplementary suture significantly increased repair-site stiffness and the 1, 2 and 3 mm gap forces, while decreasing the gap at 20 N compared to the Becker only suture ( P<0.05). The only difference between the two supplementary suture groups was that the Becker plus anchor group had increased stiffness compared to the Becker plus figure-of-eight group. In conclusion, a supplementary figure-of-eight suture and a supplementary suture using a bone anchor provide enhanced resistance to gap formation for FDP tendon–bone repairs.


2012 ◽  
Vol 38 (4) ◽  
pp. 418-423 ◽  
Author(s):  
E. McDonald ◽  
J. A. Gordon ◽  
J. M. Buckley ◽  
L. Gordon

Our goal was to investigate and compare the mechanical properties of multifilament stainless steel suture (MFSS) and polyethylene multi-filament core FiberWire in flexor tendon repairs. Flexor digitorum profundus tendons were repaired in human cadaver hands with either a 4-strand cruciate cross-lock repair or 6-strand modified Savage repair using 4-0 and 3-0 multifilament stainless steel or FiberWire. The multifilament stainless steel repairs were as strong as those performed with FiberWire in terms of ultimate load and load at 2 mm gap. This study suggests that MFSS provides as strong a repair as FiberWire. The mode of failure of the MFSS occurred by the suture pulling through the tendon, which suggests an advantage in terms of suture strength.


Sign in / Sign up

Export Citation Format

Share Document