Dynamic external fixation for fracture dislocations of the proximal interphalangeal joint

1997 ◽  
Vol 7 (2) ◽  
pp. 116-119 ◽  
Author(s):  
Randall W. Culp
2021 ◽  
pp. 175319342110593
Author(s):  
Atsuhiko Murayama ◽  
Kentaro Watanabe ◽  
Hideyuki Ota ◽  
Shigeru Kurimoto ◽  
Hitoshi Hirata

We retrospectively compared the results of volar plating and dynamic external fixation for acute unstable dorsal fracture-dislocations of the proximal interphalangeal joint with a depressed fragment. We treated 31 patients (31 fingers), 12 with volar buttress plating and 19 with dynamic external fixation. Follow-up averaged 35 and 40 months in the two groups, with a minimal 6-month follow-up. Average active flexion of the proximal interphalangeal joint was 95° after plate fixation and 87° after external fixation, with an active extension lag of –6° and –9°, respectively. Active flexion at the distal interphalangeal joint averaged 67° in the plate group and 58° in the external fixation group, with active extension lags of 0° and –5°, respectively. We conclude that both methods can obtain a good range of motion at the proximal interphalangeal joint. A limitation of the extension of the distal interphalangeal joint occurred with dynamic external fixation but not with volar buttress plating. Level of evidence: IV


2005 ◽  
Vol 30 (1) ◽  
pp. 154-160 ◽  
Author(s):  
Alejandro Badia ◽  
Felix Riano ◽  
Jessica Ravikoff ◽  
Roger Khouri ◽  
Eduardo Gonzalez-Hernandez ◽  
...  

Hand Surgery ◽  
1996 ◽  
Vol 01 (01) ◽  
pp. 31-35 ◽  
Author(s):  
Ueli Büchler

A method is presented for open reduction, bone grafting, minimal internal fixation and ancillary dynamic external fixation of unstable impacted fracture-dislocations of the proximal interphalangeal joint of the finger involving more than 40% of the surface of the joint plateau.


2020 ◽  
Vol 12 (S 01) ◽  
pp. S9-S15
Author(s):  
Arianna Gianakos ◽  
John Yingling ◽  
Christian M. Athens ◽  
Andrew E. Barra ◽  
John T. Capo

AbstractProximal interphalangeal joint (PIPJ) fractures and fracture-dislocations are common hand injuries and recognition of this injury pattern is essential in the management of these fractures. Although a variety of treatment options have been reported in the literature, the optimal treatment remains controversial. MEDLINE, EMBASE, and The Cochrane Library Database were screened for treatment strategies of PIPJ fracture and fracture-dislocation. Demographic data and outcome data were collected and recorded. A total of 37 studies including 471 patients and 480 fingers were reviewed. PIPJ range of motion (ROM) was greatest postoperatively in patients who underwent volar plate arthroplasty at 90.6 degrees. Dynamic external fixation resulted in the lowest PIP joint ROM with an average of 79.7 degrees. Recurrent pain and osteoarthritis were most often reported in extension block pinning at 38.5 and 46.2%, respectively. Open reduction and internal fixation had the highest rate of revision at 19.7%. Overall, the outcomes of PIP fractures and fracture-dislocations are based on the severity of injury, and the necessary treatment required. Closed reduction with percutaneous pinning and volar plate arthroplasty had good clinical and functional outcomes, with the lowest complication rates. Hemi-hamate arthroplasty and dynamic external fixation were utilized in more complex injuries and resulted in the lowest PIPJ ROM. This is a therapeutic, Level III study.


Hand ◽  
2019 ◽  
pp. 155894471987315 ◽  
Author(s):  
Cory Demino ◽  
Megan Yates ◽  
John R. Fowler

Background: Treatment of proximal interphalangeal joint (PIPJ) fracture-dislocations is difficult given the potential long-term complications of the involved finger and entire hand. Several surgical methods have been utilized for management of these injuries, none of which have shown consistently favorable results. The purpose of this systematic review of the literature is to report the post-operative outcomes of multiple treatment modalities for PIPJ fracture-dislocations in various studies. Methods: A literature review of PubMed and EMBASE databases was performed for all articles on PIPJ fracture-dislocations. Outcomes of interest included PIPJ range of motion, grip strength (% of contralateral hand), and quick disabilities of arm, shoulder, hand (QuickDASH). Articles were distributed into 5 groups by surgical method: open reduction, percutaneous fixation, dynamic external fixation, extension-block pinning, and hemi-hamate arthroplasty. Results: Forty-eight of 1679 total screened articles were included. The weighted means of post-operative range of motion (ROM; degrees) at final follow-up were open reduction 84.7 (n = 146), percutaneous fixation 86.5 (n = 32), dynamic external fixation 81.7 (n = 389), extension-block pinning 83.6 (n = 85), and hemi-hamate arthroplasty 79.3 (n = 52). Dorsal fracture-dislocations, regardless of surgical method, had an average ROM of 83.2 (n = 321), grip strength 91% (n = 132), and QuickDASH of 6.6 (n = 59) while pilon injuries had an average ROM of 80.2 (n = 48), grip strength 100% (n = 13), and QuickDASH of 11.4 (n = 13). Conclusion: Percutaneous fixation yielded the highest post-operative ROM at final follow-up while extension-block pinning resulted in the greatest grip strength. While dorsal fracture-dislocations produced higher average ROM and lower QuickDASH score, pilon fractures produced a higher grip strength. No treatment method or fracture type yielded consistently better outcomes than another.


Sign in / Sign up

Export Citation Format

Share Document