Comparative efficacy of sildenafil in Eisenmenger's syndrome secondary to atrial septal defect versus ventricular septal defect: a cardiac catheterisation follow-up study

2011 ◽  
Vol 21 (6) ◽  
pp. 631-638 ◽  
Author(s):  
Naveen Garg ◽  
Nishant Tripathy ◽  
Nakul Sinha

AbstractObjectivesThis study evaluates the efficacy and safety of sildenafil in patients with Eisenmenger's syndrome with special emphasis on haemodynamic parameters and its comparative efficacy in atrial septal defect versus ventricular septal defect patients.MethodsOral sildenafil was given to 22 patients with Eisenmenger's syndrome – eight with atrial septal defect and 14 with ventricular septal defect – after detailed baseline evaluation including a six-minute walk test, echocardiography, and cardiac catheterisation. Patients were followed up for a period of 6 months for functional class assessment and six-minute walk distance. Cardiac catheterisation was repeated in all patients.ResultsA significant improvement in the World Health Organization functional class, six-minute walk distance, mean pulmonary arterial pressure, and pulmonary vascular resistance was noticed. Systemic arterial and mixed venous oxygen saturations were also significantly improved along with improvement in pulmonary blood flow. None showed any significant side effects or worsening of systemic arterial saturation. At baseline, mean pulmonary arterial pressure, pulmonary vascular resistance, and pulmonary/systemic vascular resistance ratios were significantly higher in ventricular septal defect patients than in atrial septal defect patients. Atrial septal defect patients showed better response in clinical as well as haemodynamic parameters.ConclusionsSildenafil is an effective and safe agent for patients with Eisenmenger's syndrome. It improves their functional capacity as well as haemodynamic parameters. The beneficial effects are greater in patients with Eisenmenger's syndrome secondary to atrial septal defect than ventricular septal defect.

2015 ◽  
Vol 26 (3) ◽  
pp. 469-476
Author(s):  
Abdullah Ozyurt ◽  
Ali Baykan ◽  
Mustafa Argun ◽  
Ozge Pamukcu ◽  
Kazim Uzum ◽  
...  

AbstractBackgroundThe aim of this study was to investigate the potential role of N-terminal pro-brain natriuretic peptide in the assessment of shunt severity and invasive haemodynamic parameters in children with atrial septal defects and ventricular septal defects.MethodsThis is a prospective, controlled (n:62), observational study. Correlation analysis was performed between N-terminal pro-brain natriuretic peptide levels and various invasive haemodynamic measurements in 127 children (ventricular septal defect: 64; atrial septal defect: 63). A ratio of pulmonary to systemic blood flow (Qp/Qs⩾1.5) was considered to indicate a significant shunt.ResultsStatistically significant relationship was found between the mean N-terminal pro-brain natriuretic peptide values of the patients, with Qp/Qs⩾1.5 in both defect types and control group. For ventricular septal defect, N-terminal pro-brain natriuretic peptide level⩾113.5 pg/ml was associated with high specificity and sensitivity for determining the significant shunt. In addition, the cut-off point for determining the significant shunt for atrial septal defect was 57.9 pg/ml. Significant positive correlation was found between all invasive haemodynamic parameters and N-terminal pro-brain natriuretic peptide levels in patients with ventricular septal defects. Whereas significant positive correlation was found only between mean pulmonary artery pressure, right ventricular end-diastolic pressure, and systemic pressure to pulmonary pressure ratio and N-terminal pro-brain natriuretic peptide levels in patients with atrial septal defects.ConclusionOur study demonstrated that the N-terminal pro-brain natriuretic peptide measurements could be used as a supporting parameter in determining significance of the shunt.


Author(s):  
Bahram Alamdary Badlou

We report a rare case of unrepaired Tetralogy_Pantalogy of Fallot (TOF_POF) in a 20 years old Persian girl Mrs Zeynab S., who presented with cyanotic finger tops appearance, ongoing chronic thrombolytic destruction processes, and remarkable thrombocytopenia [1,2], heart ventricular septal defect (VSD), and might atrial septal defect (ASD), anxiety, sleep disorders, nightmares, and limited social life. Additionally, the relationship between underlying mechanisms, possible treatments of the thrombocytopenia, erythrocytosis, and unrepaired cardiovascular leakages remains unknown.


2014 ◽  
Vol 25 (2) ◽  
pp. 237-244 ◽  
Author(s):  
Sean Wallace ◽  
Gaute Døhlen ◽  
Henrik Holmstrøm ◽  
Christian Lund ◽  
David Russell

AbstractIntroduction: The aim of this prospective study was to determine the frequency and composition of cerebral microemboli in a paediatric population during transcatheter atrial septal defect closure. Methods: Multi-frequency transcranial Doppler was used to detect microembolic signals in the middle cerebral artery of 24 patients. Embolic signals were automatically identified and differentiated according to their composition, gaseous or solid. The procedure was divided into five periods: right cardiac catheterisation; left cardiac catheterisation; pulmonary angiography; balloon sizing; and device placement. Results: Microemboli were detected in all patients. The median number of signals was 63 and over 95% gaseous. The total number of microembolic signals detected during two periods – balloon sizing and sheath placement and device placement – was not significantly different (median: 18 and 25, respectively) but was significantly higher than each of the other three periods (p<0.001). In eight patients, the device was opened more than once and the number of embolic signals decreased with each successive device deployment. There was no correlation between the number of microembolic signals and fluoroscopic time, duration of procedure, age, or device size. Conclusion: This is the first study to investigate the timing and composition of cerebral microemboli in a paediatric population during cardiac catheterisation. Microembolic signals were related to specific catheter manipulations but were not associated with fluoroscopic time or duration of procedure.


1989 ◽  
Vol 63 (5) ◽  
pp. 327-331 ◽  
Author(s):  
John M. Neutze ◽  
Tatsuo Ishikawa ◽  
Patricia M. Clarkson ◽  
A.Louise Calder ◽  
Brian G. Barratt-Boyes ◽  
...  

2018 ◽  
Vol 82 (11) ◽  
pp. 2925-2926
Author(s):  
Hiromi Kayamori ◽  
Takeshi Kashimura ◽  
Yosuke Horii ◽  
Tsutomu Kanazawa ◽  
Toshio Fujita ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document