scholarly journals Initial use of endothelial progenitor cells capturing stents in paediatric congenital heart disease

2013 ◽  
Vol 24 (5) ◽  
pp. 900-904 ◽  
Author(s):  
Nuno Cabanelas ◽  
José D. F. Martins ◽  
Fátima Pinto

AbstractIntroductionStenosis, mediated by neointimal hyperplasia and thrombosis, is a major limiting factor in successful stent implantation. The introduction of a stent, coated in its endoluminal surface by antihuman CD34 antibodies with endothelial progenitor cell-capturing properties, opens the possibility of promoting a rapid and normal functioning coverage by endothelium and thus avoids both an excessive cell proliferation within stent and the need for long-term dual antiplatelet therapy. These stents, developed for adult coronary artery disease, have not yet been implanted in children or in those with congenital heart disease.Objective and methodsIn this paper, we describe the implantation of Genous®stents in three children with cyanotic congenital heart disease and obstructed systemic-to-pulmonary shunts. We describe the use of this stent and address its potential feasibility in paediatric congenital heart disease.ResultsTo maintain the patency of two modified Blalock–Taussig shunts and one ductus arteriosus, four Genous®stents were implanted in three infants with cyanotic heart disease. All procedures were immediately successful, with resolution of stenosis and improvement in transcutaneous oxygen saturation from 66% ± 3.6% to 92% ± 2.6%. In the follow-up, one stent had no occlusion; however, the remaining two had partial occlusion after 5 and 5.5 months, which were successfully managed with balloon dilatation preceding elective definitive surgical correction.ConclusionIn our preliminary experience, we demonstrated that Genous®stent implantation was feasible in infants with complex congenital heart disease. Additional studies with larger samples and longer follow-up are required to confirm the potential benefits of this technology in this clinical setting.

2005 ◽  
Vol 13 (3) ◽  
pp. 274-276 ◽  
Author(s):  
Amjad Kouatli ◽  
Jameel Al-Ata ◽  
M Omar Galal ◽  
Muhammed A Amin ◽  
Arif Hussain

A 14-year-old female with complex congenital heart disease underwent a left-sided classical Blalock Taussig (BT) shunt 15 days after birth. Ten years after the operation her oxygen saturation had decreased significantly. An angiography revealed a severely stenosed BT shunt. Balloon dilation including implantation of a 6 × 13 mm stent was performed successfully. Immediately after intervention, oxygen saturation rose from 55% to 80 84% in room air. Follow-up at a year and a half later showed the classical BT shunt was still patent.


2019 ◽  
Vol 3 (4) ◽  
pp. 1-4
Author(s):  
Julia Illner ◽  
Holger Reinecke ◽  
Helmut Baumgartner ◽  
Gerrit Kaleschke

Abstract Background Adults with complex congenital heart disease palliated with systemic-to-pulmonary artery shunts have become rare and represent a particularly challenging patient group for the cardiologist. One of the complications and causes of severe clinical deterioration during long-term follow-up are progressive obstruction or total occlusion of the shunt. The risk for surgical intervention is frequently high and catheter intervention may be complicated by complex anatomy and shunt calcification. Case summary We report the case of a 47-year-old man with uncorrected (palliated) pulmonary atresia and ventricular septal defect who presented with progressive cyanosis (oxygen saturation 69%) and decreasing exercise capacity. Computed tomography revealed a totally occluded modified left Blalock–Taussig (BT) shunt and a severely stenosed central shunt (Waterston–Cooley) in a patient with confluent but hypoplastic pulmonary arteries and multiple major aortic pulmonary collaterals. Due to a high operative risk, an interventional, percutaneous approach was preferred to re-do surgery. From a radial access the calcified BT shunt could be crossed with a hydrophilic guidewire. Then, a rotational thrombectomy, balloon dilatation, and bare-metal stenting at the proximal and distal anastomoses were performed. Post-interventionally, peripheral oxygen saturation increased from 69% to 82%. Clopidogrel was administered for 1 month after bare-metal stenting. At 1-year follow-up, the BT shunt was still patent on echocardiography and exercise tolerance markedly improved. Discussion This case highlights the benefit of percutaneous rotational thrombectomy followed by stenting of chronically occluded systemic-to-pulmonary artery shunts for further palliation in adult patients with complex congenital heart disease not suitable for surgical repair.


2003 ◽  
Vol 75 (2) ◽  
pp. 399-411 ◽  
Author(s):  
Joseph A Dearani ◽  
Gordon K Danielson ◽  
Francisco J Puga ◽  
Hartzell V Schaff ◽  
Carole W Warnes ◽  
...  

Author(s):  
Qi-Liang Zhang ◽  
Wen-Peng Xie ◽  
Yu-Qing Lei ◽  
Hua Cao ◽  
Qiang Chen

Abstract Background During the COVID-19 pandemic, parents of infants having medical problem face challenges of insufficient medical resources at home. The purpose of this study was to investigate the effect of WeChat-based telehealth services on the preoperative follow-up of infants with congenital heart disease (CHD) during the COVID-19 pandemic. Methods This study retrospectively analyzed the medical records of 190 infants with CHD who underwent remote follow-up via WeChat from December 2019 to May 2020 in Fujian Maternity and Child Health Hospital, Affiliated Hospital of Fujian Medical University. In addition, the psychological benefits of WeChat on the parents of these infants were analyzed. Results In total, 190 infants were involved in this study, including 72 cases of ventricular septal defects, 42 cases of patent ductus arteriosus, 55 cases of atrial septal defects, 3 cases of tetralogy of Fallot, 2 cases of endocardial cushion defects, 12 cases of pulmonary stenosis, 2 cases of total anomalous pulmonary venous connection and 2 cases of aortic arch constriction. During the follow-up period, 48 infants who received surgical indications were hospitalized in time for surgical treatment. It was recommended that 10 infants with respiratory tract infections be treated in local hospitals through the WeChat platform. We provided feeding guidance to 28 infants with dysplasia through the WeChat platform. The psychological evaluation results of parents showed that the median score and range of Self-Rating Depression Scale (SDS) scores were 42 and 32-58, respectively. Nine parents (4.7%) were clinically depressed, while the majority had mild depression. The median score and range of Self-Rating Anxiety Scale (SAS) scores were 44 and 31-59, respectively. Twenty parents (10.5%) had clinical anxiety, while the rest had mild anxiety. Conclusion During the COVID-19 pandemic, follow-up management and health services for infants with CHD prior to surgery through the WeChat platform were useful in identifying the state of an infants’ condition as well as in identifying and relieving care pressure, anxiety and depression in the parents.


2014 ◽  
Vol 7 (4) ◽  
pp. 652-657 ◽  
Author(s):  
Matthew R. Williams ◽  
Suzanne M. Shepard ◽  
Nicole K. Boramanand ◽  
John J. Lamberti ◽  
James C. Perry

Sign in / Sign up

Export Citation Format

Share Document