Serum free light chain assessment in monoclonal gammopathy and kidney disease

2009 ◽  
Vol 5 (11) ◽  
pp. 621-628 ◽  
Author(s):  
Colin A. Hutchison ◽  
Kolitha Basnayake ◽  
Paul Cockwell
2019 ◽  
Vol 23 (6) ◽  
pp. 763-772
Author(s):  
Olga Kukuy ◽  
Batia Kaplan ◽  
Sizilia Golderman ◽  
Alexander Volkov ◽  
Adrian Duek ◽  
...  

Blood ◽  
2006 ◽  
Vol 108 (11) ◽  
pp. 5011-5011
Author(s):  
Jerry A. Katzmann ◽  
Angela Dispenzieri ◽  
Robert Kyle ◽  
Melissa R. Snyder ◽  
Mathew F. Plevak ◽  
...  

Abstract Due to the diagnostic sensitivity of serum free light chain quantitation for monoclonal light chain diseases, it has been suggested that urine assays no longer need be performed as part of the diagnostic algorithm for monoclonal proteins. We reviewed our experience to determine the relative diagnostic contribution of urine assays. Methods: Patients with a monoclonal gammopathy and monoclonal urinary protein at initial diagnosis who also had a serum immunofixation and serum free light chain quantitation within 30 days of diagnosis were identified (n = 428). The laboratory results for serum protein electrophoresis, serum immunofixation, serum free light chain, urine protein electrophoresis, and urine immunofixation were reviewed. Results: The patients in this cohort had diagnoses of multiple myeloma, primary amyloid, monoclonal gammopathy of undetermined significance, smoldering multiple myeloma, solitary plasmacytomas, and other less frequently detected monoclonal gammopathies. By definition of the cohort, all 428 had a monoclonal urine protein. 86% had an abnormal serum free light chain K/L ratio, 81% had an abnormal serum protein electrophoresis, and 94% had an abnormal serum immunofixation. In only 2 patients, however, were all 3 serum assays normal. Both of these were patients with monoclonal gammopathy of undetermined significance (idiopathic Bence Jones proteinuria). Conclusion: Discontinuation of urine studies and reliance on a diagnostic algorithm using solely serum studies (protein electrophoresis, immunofixation, and free light chain quantitation), missed 2 of the 428 monoclonal gammopathies (0.5 %) with urinary monoclonal proteins, and these 2 cases required no medical intervention.


PLoS ONE ◽  
2015 ◽  
Vol 10 (10) ◽  
pp. e0141404
Author(s):  
Lakhvir K. Assi ◽  
Natasha McIntyre ◽  
Simon Fraser ◽  
Scott Harris ◽  
Colin A. Hutchison ◽  
...  

Author(s):  
Richard B Fulton ◽  
Suran L Fernando

Background The potential for serum free light chain (sFLC) assay measurements to replace urine electrophoresis (uEPG) and to also diminish the need for serum immunofixation (sIFE) in the screening for monoclonal gammopathy was assessed. A testing algorithm for monoclonal protein was developed based on our data and cost analysis. Methods Data from 890 consecutive sFLC requests were retrospectively analysed. These included 549 samples for serum electrophoresis (sEPG), 447 for sIFE, and 318 for uEPG and urine immunofixation (uIFE). A total of 219 samples had sFLC, sEPG, sIFE and uEPG + uIFE performed. The ability of different test combinations to detect the presence of monoclonal proteins was compared. Results The sFLC κ/ λ ratio (FLC ratio) indicated monoclonal light chains in 12% more samples than uEPG + uIFE. The combination of sEPG and FLC ratio detected monoclonal proteins in 49% more samples than the combination of sEPG and sIFE. Furthermore, the sEPG + FLC ratio combination detected monoclonal protein in 6% more samples than were detected by the combined performance of sEPG, sIFE, uEPG and uIFE. However, non-linearity of the assay, the expense of repeat determinations due to the narrow measuring ranges, and frequent antigen excess checks were found to be limitations of the sFLC assay in this study. Conclusion The FLC ratio is a more sensitive method than uIFE in the detection of monoclonal light chains and may substantially reduce the need for onerous 24 h urine collections. Our proposed algorithm for the evaluation of monoclonal gammopathy incorporates the sFLC assay, resulting in a reduction in the performance of labour intensive sIFE and uEPG + uIFE while still increasing the detection of monoclonal proteins.


PLoS ONE ◽  
2015 ◽  
Vol 10 (7) ◽  
pp. e0129980 ◽  
Author(s):  
Lakhvir K. Assi ◽  
Natasha McIntyre ◽  
Simon Fraser ◽  
Scott Harris ◽  
Colin A. Hutchison ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document