scholarly journals Safety and efficacy of repeated crosslinking assisted by transepithelial double-cycle iontophoresis in keratoconus progression after primary corneal crosslinking

Eye ◽  
2021 ◽  
Author(s):  
Huping Wu ◽  
Lan Li ◽  
Shunrong Luo ◽  
Xie Fang ◽  
Xumin Shang ◽  
...  

Abstract Objectives To evaluate the safety and efficacy of repeated corneal collagen crosslinking assisted by transepithelial double-cycle iontophoresis (DI-CXL) in the management of keratoconus progression after primary CXL. Methods A retrospective analysis was conducted in the patients who underwent repeated CXL between 2016 and 2018. These patients were treated with DI-CXL if keratoconus progression was confirmed after primary CXL. Scoring of ocular pain and corneal epithelial damage, visual acuity, corneal tomography, in vivo corneal confocal microscopy (IVCM) was performed before and at 3, 6, 12, and 24 months after DI-CXL. Results Overall, 21 eyes of 12 patients (mean age 17.3 ± 1.9 years) were included in this study. Before DI-CXL, an average increase of 4.26 D in Kmax was detected in these patients with a mean follow-up interval of (23.0 ± 13.7) months. After DI-CXL, corneal epithelial damage rapidly recovered within days. Visual acuity remained unchanged with follow-up of 24 months. When compared to baseline, significant decreases were observed in Kmax (at 3 months) and K2 (at 3 and 6 months) after DI-CXL. Corneal thickness of thinnest point significantly decreased at 3 months postoperatively. When compared to baseline, no significant differences were found in any of the refractive or tomographic parameters at 12 and 24 months. IVCM revealed trabecular patterned hyperdense tissues after DI-CXL in the anterior stroma at the depth of 200 μm or more. No corneal infiltration or persistent epithelial defect was recorded after DI-CXL. Conclusion DI-CXL is safe and effective as a good alternative in stabilizing keratoconus progression after primary CXL.

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
F. Cifariello ◽  
M. Minicucci ◽  
F. Di Renzo ◽  
D. Di Taranto ◽  
G. Coclite ◽  
...  

Aim. To evaluate two different techniques of cross-linking: standard epithelium-off (CXL epi-off) versus transepithelial (CXL epi-on) cross-linking in patient with progressive keratoconus.Methods. Forty eyes from 32 patients with progressive keratoconus were prospectively enrolled from June 2014 to June 2015 in this nonblinded, randomized comparative study. Twenty eyes were treated by CXL epi-off and 20 by CLX epi-on, randomly assigned, and followed for 2 years. All patients underwent a complete ophthalmologic testing that included uncorrected and best corrected visual acuity, central and peripheral corneal thickness, corneal astigmatism, simulated maximum, minimum, and average keratometry, corneal confocal microscopy, Schirmer I and break-up time (BUT) tests, and the Ocular Surface Disease Index. Intra- and postoperative complications were recorded. The solution used for CXL epi-off comprised riboflavin 0.1% and dextran 20.0% (Ricrolin), whereas the solution for CXL epi-on (Ricrolin TE) comprised riboflavin 0.1%, dextran 15.0%, trometamol (Tris), and ethylenediaminetetraacetic acid. Ultraviolet-A treatment was performed with a UV-X system at 3 mW/cm2.Results. In both groups, a significant improvement in visual function (Group 1: baseline 0.36 ± 0.16 logMAR, two-year follow-up 0.22 ± 0.17 logMAR,p=0.01; Group 2: baseline 0.32 ± 0.18 logMAR, 2-year follow-up 0.27 ± 0.19 logMAR,p=0.01) was recorded. Keratometry remained unchanged in both groups. The mean corneal thickness showed a significant reduction (mean difference of corneal thickness: −55 micron and −71 micron, resp.). One-month after treatment, OSDI©reached 13.56 ± 2.15 in Group 1 (p=0.03) and 11.26 ± 2.12 in Group 2 (p=0.04). At confocal microscopy, abnormal corneal nerve alterations were found in both groups. Fibrotic reaction (43.75%) and activated keratocyte (62.6%) were more commonly recorded in Group 1 than in Group 2 (25.0% and 18.75%), withp=0.668and 0.356, respectively.Conclusion. Our findings demonstrate that both procedures are able to slow keratoconus progression. Both treatment modalities are equivalent in terms of results and related complications. CXL epi-on technique is preferable to CXL epi-off since it preserves the corneal thickness and improves visual acuity, also reducing the postoperative ocular discomfort during the study period.


2020 ◽  
pp. bjophthalmol-2019-315260 ◽  
Author(s):  
Mi Tian ◽  
Weijun Jian ◽  
Xiaoyu Zhang ◽  
Ling Sun ◽  
Xingtao Zhou

PurposeTo investigate the long-term safety and efficacy of accelerated transepithelial corneal cross-linking (ATE-CXL) in children with progressive keratoconus.MethodsFifty-three eyes of 41 paediatric patients (34 boys, 7 girls; mean age 14.81±1.96 years) undergoing ATE-CXL were enrolled in the study. Corrected distance visual acuity (CDVA) and manifest refraction were assessed preoperatively and 36 months postoperatively. Corneal keratometry, corneal thickness and posterior elevation were measured using Pentacam preoperatively and 1, 6, 12 and 36 months postoperatively. Pachymetry and epithelial thicknesses were measured using optical coherence tomography preoperatively and 6, 12, and 36 months postoperatively.ResultsThirty-six months postoperatively, CDVA improved from 0.32±0.28 to 0.26±0.25 in logarithm of the minimum angle resolution (p=0.025). Maximum keratometry was 58.73±9.70 D preoperatively and 59.20±10.24, 58.28±9.33, 57.88±9.99 and 58.98±10.79 D at 1, 6, 12 and 36 months postoperatively throughout the 36-month follow-up period (p>0.05). Similarly, corneal central thickness, which was 492.42±33.83 µm postoperatively, also remained stable during the 36-month follow-up (p>0.05). Both posterior central elevation and posterior highest elevation were stable at 12 months after ATE-CXL (p>0.05), but increased at 36 months postprocedure (p<0.05). Corneal pachymetry and epithelial thicknesses remained stable throughout the follow-up period (p>0.05).ConclusionsATE-CXL is a safe and effective treatment in paediatric progressive keratoconus patients, leading to stable keratometry and corneal thickness throughout the 36-month follow-up.


2020 ◽  
Vol 259 (1) ◽  
pp. 239-246
Author(s):  
Huping Wu ◽  
Shunrong Luo ◽  
Xie Fang ◽  
Xumin Shang ◽  
Zhiwen Xie ◽  
...  

Abstract Purpose The aim of this study is to compare the long-term effects of transepithelial corneal crosslinking with two continuous cycles of iontophoresis (EI-CXL) and conventional corneal crosslinking (C-CXL) in adults with progressive keratoconus. Methods A retrospective analysis was conducted in adults who underwent C-CXL or EI-CXL between 2013 and 2015. Visual acuity, corneal tomography, anterior segment optical coherence tomography, in vivo corneal confocal microscopy (IVCM), and endothelial cell count (ECC) were performed preoperatively and 5 years postoperatively. Results Sixty-eight patients with a mean age of (24.3 ± 3.8) years were included, 34 for each group. After CXL, UCVA or BCVA remained stable, while the spherical diopter, cylinder diopter, spherical equivalent, and Kmax significantly decreased at 1, 2, and 3 years in both groups than baseline (P < 0.05). No significant differences were found in any refractive or tomographic parameters as well as the minimal corneal thickness between groups during follow-up. At 5 years, Kmax was slightly higher in EI-CXL group (58.16 ± 6.28) than that of C-CXL group (57.46 ± 4.98). At 3 and 5 years, the minimal corneal thickness in C-CXL group was still significantly lower than baseline (P < 0.05). IVCM demonstrated the demarcation zone at a mean depth of (302.0 ± 41.7) μm after C-CXL, and at (251.2 ± 28.1) μm after EI-CXL (P < 0.001). Keratocyte repopulation was detectable at all follow-up timepoint in both groups. Postoperative complications including progression were recorded in 6 patients (11.7%) after C-CXL and 3 patients (8.8%) after EI-CXL. ECC remained stable in both groups. Conclusion EI-CXL showed approximate efficacy with C-CXL in stabilizing progressive keratoconus in adults. EI-CXL has the potential to be a preferable transepithelial protocol.


2021 ◽  
pp. 112067212110206
Author(s):  
Iliya Simantov ◽  
Lior Or ◽  
Inbal Gazit ◽  
Biana Dubinsky-Pertzov ◽  
David Zadok ◽  
...  

Background: Retrospective cohort study evaluating long term keratoconus progression amongst cross-linking (CXL) treated pediatric patients in the treated and the fellow untreated eyes. Methods: Data on 60 eyes of 30 patients, 18 years old or younger, who underwent CXL in at least one eye was collected and analyzed. Follow-up measurements taken from the treated and untreated eye up to 7 years after CXL treatment, were compared to baseline measurements. Parameters included uncorrected distance visual acuity (UCDVA), best-corrected spectacle visual acuity (BCSVA), manifest refraction, pachymetry, corneal tomography, and topography. Results: Mean age of patients was 16 ± 2.1 years. For the treated eyes, during follow-up period mean UCDVA had improved (from 0.78 ± 0.22 at baseline to 0.58 ± 0.26 logMAR at 7 years; p = 0.13), as well as mean BCSVA (from 0.23 ± 0.107 at baseline to 0.172 ± 0.05 logMAR at 7 years; p = 0.37). The mean average keratometry showed a significant flattening (from 49.95 ± 4.04 to 47.94 ± 3.3 diopters (D); p < 0.001), However there was no change in the mean maximal keratometry. The mean minimal corneal thickness (MCT) showed a significant mild reduction of 26 µm ( p = 0.006). Although statistically insignificant, the mean manifest cylinder was also reduced to 2D ( p = 0.15). During the follow-up period, eight untreated eyes (26.6%) deteriorated and underwent CXL, while only one treated eye (3.33%) required an additional CXL. Conclusion: CXL is a safe and efficient procedure in halting keratoconus progression in the pediatric population, the fellow eye needs to be carefully monitored but only a 25% of the patients will require CXL in that eye during a period of 7 years.


2021 ◽  
pp. 112067212110590
Author(s):  
Cristina Monterosso ◽  
Marco Antonini ◽  
Antonio Di Zazzo ◽  
Daniele Gaudenzi ◽  
Luigi Caretti ◽  
...  

Purpose To evaluate postoperative safety of femtosecond laser deep anterior lamellar keratoplasty performed with an innovative anvil profile in keratoconus patients. Methods This is a single-center, retrospective cohort study. We reviewed medical records of 89 keratoconus patients that underwent femtosecond laser deep anterior lamellar keratoplasty surgery (46 eyes) and manual deep anterior lamellar keratoplasty (47 eyes). Inclusion criteria required: age > 18 years old, best-corrected visual acuity < 0.3 LogMAR, continuous suture of the graft, postoperative immunomodulant regimen with dexamethasone 0.1% for 6 months and at least 12 months follow-up. Previous eye surgery, hydrops, and other ocular disease were excluded. The main outcome measures were postoperative events: rejections, persistent epithelial defects, and graft failures. Results During the follow-up (20 ± 6 months) graft rejection was diagnosed in 0 of femtosecond laser deep anterior lamellar keratoplasty versus 6 (17%) of manual deep anterior lamellar keratoplasty [ p 0.027], persistent epithelial defect in 0 of femtosecond laser deep anterior lamellar keratoplasty versus in 4 (11%) of manual deep anterior lamellar keratoplasty [ p 0.048] and graft failure occurred in 4 (11%) of manual deep anterior lamellar keratoplasty. The best-corrected visual acuity, after removal of sutures, was better in the femtosecond laser deep anterior lamellar keratoplasty group 0.09 ± 0.08 LogMAR versus 0.16 ± 0.13 LogMAR in manual deep anterior lamellar keratoplasty [ p 0.035] group although refractive spherical equivalent and cylinder, topographic average keratometry and cylinder were similar. Conclusions Anvil-shaped femtosecond laser deep anterior lamellar keratoplasty in keratoconus surgery increases safety and readiness of recovery, decreasing the incidence of corneal rejection, epithelial defects, graft failures, and producing better best-corrected visual acuity after removal of sutures.


2020 ◽  
pp. 112067212094566
Author(s):  
Michael A Grentzelos ◽  
Nafsika Voulgari ◽  
Clarice Giacuzzo ◽  
Konstantinos Droutsas ◽  
George D Kymionis

Purpose: To report the evolution of corneal flattening after repeated corneal cross-linking (CXL) in a patient with progressive keratoconus during a 6-year follow-up. Methods: Case report. Results: A 27-year-old female underwent CXL for progressive keratoconus. Postoperatively, corneal topography revealed keratoconus progression with an increase of 1.20 diopters (D) in maximum keratometry (Kmax) and CXL was repeated. After the second treatment, a continuing significant corneal flattening (up to 16.00 D in Kmax) was observed during the first 5 years followed by stabilization during the last sixth year of follow-up. Both uncorrected and corrected distance visual acuity were improved while corneal thickness was decreased. There were no complications such as corneal opacification or endothelial cells decrease during the follow-up period. Conclusion: Repeated CXL can induce an excessive corneal flattening more pronounced during the first years of follow-up followed by stabilization thereafter.


2017 ◽  
Vol 2017 ◽  
pp. 1-6
Author(s):  
Daniele Veritti ◽  
Valentina Sarao ◽  
Paolo Lanzetta

Purpose.To evaluate prospectively the safety and efficacy of optimal keratoplasty for the correction of hyperopia and presbyopia.Methods. Consecutive patients undergoing bilateral optimal keratoplasty for refractive presbyopic and hypermetropic corrections were enrolled. Each patient received a complete ophthalmologic examination at baseline, 1 hour, 1 day, 1 week, 1 month, 3 months, and 6 months after treatment.Results. The study included 40 consecutive eyes of 20 patients. All patients reached the 6-month follow-up. No serious intra- or postoperative complications were recorded. Monocular and binocular uncorrected near visual acuities improved significantly during the follow-up (p<0.001). Binocular uncorrected distance visual acuity in presbyopic patients improved from 0.28 logMAR to a maximum of 0.04 logMAR (from 20/38 to 20/22 Snellen equivalent) the day after the treatment and remained significantly better than baseline until the end of the follow-up. A significant improvement of patient satisfaction for near (p<0.001) and distance (p=0.007) activities was seen the day after treatment and was maintained throughout the follow-up.Conclusions.Optimal keratoplasty is a safe, noninvasive, rapid, pain-free, office-based procedure. It offers low to moderate hyperopes and presbyopes an improvement in uncorrected near visual acuity while maintaining or improving their distance visual acuity.


2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Ercüment Bozkurt ◽  
Engin Bilge Ozgurhan ◽  
Betul Ilkay Sezgin Akcay ◽  
Tugba Kurt ◽  
Yusuf Yildirim ◽  
...  

Purpose. To report the visual, refractive, and corneal topography and wavefront aberration results of accelerated corneal cross-linking (CXL) during a 24-month follow-up.Methods. Forty-seven eyes underwent riboflavin-ultraviolet A-induced accelerated CXL treatment (30 mW/cm2with a total dose of 7.2 joules/cm2). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical and cylindrical values, keratometry (K) measurements (Ksteep,Kflat,Kavg, andKapex), central corneal thickness, and anterior corneal aberrometric analyses including total wavefront error (WFE), total high order aberration (HOA), astigmatism, trefoil, coma, quadrafoil, secondary astigmatism, and spherical aberration were evaluated.Results. The mean UDVA and CDVA were significantly improved at 1 (p=0.003andp=0.004, resp.) and 2 years after treatment (p=0.001andp=0.001, resp.). The meanKsteep,Kflat,Kaverage, andKapexvalues were significantly lower than baseline at 12 months (p=0.008,p=0.024,p=0.001, andp=0.014, resp.) and 24 months (p=0.014,p=0.017,p=0.001, andp=0.012, resp.). Corneal thickness showed a significant decrease at 1 month. Total HOA and coma decreased significantly at the 12-month (p=0.001andp=0.009, resp.) and 24-month visits (p=0.001andp=0.007, resp.).Conclusion. Accelerated CXL (30 mW/cm2) was found to be effective in improving UDVA, CDVA, corneal topography readings, total HOA, and coma aberrations during the 24-month follow-up.


2018 ◽  
Vol 28 (1) ◽  
pp. 25-31 ◽  
Author(s):  
Elisa I. Postorino ◽  
Laura Rania ◽  
Emanuela Aragona ◽  
Carmen Mannucci ◽  
Angela Alibrandi ◽  
...  

Purpose: Dry eye disease (DED) is a common condition causing substantial burden. A randomized, controlled, single-masked study was performed in 40 patients with mild to moderate DED to evaluate the efficacy and safety of a collyrium based on crosslinked hyaluronic acid (XLHA) with coenzyme Q10 (CoQ10). Methods: Enrolled subjects were divided into 2 groups: group A, treated with XLHA + CoQ10; and group B, treated with hyaluronic acid (HA). Eyedrops were administered 4 times daily for 3 months. The Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), corneal and conjunctival staining, and meibomian gland assessment (MGD) were evaluated; furthermore, corneal aesthesiometry, in vivo corneal confocal microscopy, visual acuity, intraocular pressure (IOP), and fundus examination were performed. Results: At the end of treatment, OSDI score significantly decreased in groups A and B (p<0.01 and p<0.05, respectively); the decrease was significantly higher in group A. Corneal staining decreased in both groups, with lower scores in group A. The MGD was significantly ameliorated in group A patients. No differences were found for corneal aesthesiometry or TBUT. Epithelial cell reflectivity was significantly reduced only in group A. For keratocytes and stromal matrix parameters, there was a significant improvement in group A. No changes were found for visual acuity, IOP, or fundus examination. Conclusions: The XLHA + CoQ10 treatment showed greater effectiveness in DED compared to HA alone, probably due to the longer permanency on ocular surface and the antioxidant activity of CoQ10. Therefore, XLHA + CoQ10 eyedrops could represent a new possibility in dry eye treatment.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Sri Ganesh ◽  
Sheetal Brar

Purpose. To study the safety and clinical outcomes of ReLEx SMILE with accelerated cross-linking in individuals with thinner corneas, borderline topography, and higher refractive errors.Methods. Eligible patients first underwent SMILE procedure for correction of myopic refractive error. Following the removal of lenticule, 0.25% riboflavin in saline was injected into the interface and allowed to diffuse for 60 seconds. Finally, eye was exposed to UV-A radiation of 45 mW/cm2for 75 seconds through the cap. Total energy delivered was 3.4 J/cm2.Results. 40 eyes of 20 patients with mean age of 26.75 ± 5.99 years were treated. Mean follow-up was 12 months ± 28.12 days. Mean spherical equivalent (SE) was −5.02 ± 2.06 D preoperatively and −0.24 ± 0.18 D postoperatively. The mean central corneal thickness (CCT) and keratometry changed from 501 ± 25.90 µm to 415 ± 42.26 µm and 45.40 ± 1.40 D to 41.2 ± 2.75 D, respectively. Mean uncorrected visual acuity (UCVA) was 20/25 or better in all eyes. No eyes lost lines of corrected distant visual acuity (CDVA). There were no complications like haze, keratitis, ectasia, or regression.Conclusion. Based on the initial clinical outcome it appears that SMILE Xtra may be a safe and feasible modality to prevent corneal ectasia in susceptible individuals.