scholarly journals Permanent pacemaker dependency in patients with new left bundle branch block and new first degree atrioventricular block after transcatheter aortic valve implantation

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Bonnie Hartrampf ◽  
David Jochheim ◽  
Julius Steffen ◽  
Thomas Czermak ◽  
Sebastian Sadoni ◽  
...  

AbstractConduction disorders with need for permanent pacemaker (PPM) implantation remain frequent complications after transcatheter aortic valve implantation (TAVI). Up to 22% of PPM after TAVI are implanted for new onset left bundle branch block (LBBB) and atrioventricular block (AVB) I. However, clinical benefit and predictors of ventricular pacing in TAVI patients receiving PPM for this indication remain unclear. We retrospectively evaluated pacemaker interrogation data of patients who received a PPM post TAVI for new LBBB and new AVB I. The primary endpoint of this study was relevant ventricular pacing (ventricular pacing rate: Vp ≥ 1%) at the first outpatient pacemaker interrogation. Secondary endpoints were predictors for relevant ventricular pacing. At the first pacemaker interrogation (median follow up at 6.23 [2.8–14.8] months), median ventricular pacing frequency was 1.0% [0.1–17.8]. Out of 61 patients, 36 (59%) had Vp rates ≥ 1%. Patients with frequent ventricular pacing showed longer QRS duration (155 ms ± 17 ms vs. 144 ms ± 18 ms, p = 0.018) at the time of PPM implantation and were less likely treated with a balloon-expandable Edwards Sapiens Valve (39% vs. 12%, p = 0.040). Our findings suggest that the majority of patients with new LBBB and new AVB I after TAVI show relevant ventricular pacing rates at follow up. Further prospective studies are necessary to identify patients at higher risk of pacemaker dependency.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
S.S Arri ◽  
A Myat ◽  
I Malik ◽  
N Curzen ◽  
A Baumbach ◽  
...  

Abstract Introduction New onset left bundle branch block (LBBB) is the most common conduction disturbance associated with transcatheter aortic valve implantation (TAVI). It has been shown to adversely affect cardiac function and increase re-hospitalisation, although its impact on mortality remains contentious. Methods We conducted an observational cohort analysis of all TAVI procedures performed by 13 heart teams in the United Kingdom from inception of their structural programmes until 31st July 2013. The primary outcome was 1-year all-cause mortality. Secondary outcomes included left ventricular ejection fraction (LVEF) at 30 days and need for a post-TAVI permanent pacemaker (PPM). Results 1785 patients were eligible for inclusion to the study. The primary analysis cohort was composed of 1409 patients with complete electrocardiographic (ECG) data pre- and post-TAVI. Pre-existing LBBB was present in 200 (14.2%) patients. New LBBB occurred in 323 (22.9%) patients post TAVI, which resolved in 99 (7%) patients prior to discharge. A balloon-expandable device was implanted in 968 (69%) patients, whilst 421 (30%) patients received a self-expandable valve. New LBBB was observed in 120 (12.4%) and 192 (45.6%) patients receiving a balloon- or self-expandable prosthesis respectively. Overall 1-year all-cause mortality post TAVI was 18.7%. New onset LBBB was not associated with an increase in 1-year all-cause mortality (p=0.416). Factors that were associated with mortality included an increasing logistic EuroScore (p=0.05), history of previous balloon aortic valvuloplasty (p=0.001), renal impairment (p=0.003), previous myocardial infarction with pre-existing LBBB (p=0.028) and atrial fibrillation (p=0.039). Lower baseline peak and mean AV gradients were also associated with greater mortality at 1 year (p=0.001), likely reflecting underlying left ventricular dysfunction. In the majority of patients, LVEF remained unchanged following TAVI. Interestingly, the presence or absence of new onset LBBB did not affect LVEF improvement at 30 days. 10% of patients required a PPM post TAVI. Predictors of PPM included new LBBB (OR 2.6, p<0.001), pre-TAVI left ventricular systolic impairment (OR 1.2, p=0.037), a self-expandable device (p<0.001), and pre-existing RBBB (OR 4.0, p<0.001). Conclusions These findings suggest that new onset LBBB post TAVI does not increase mortality at 1 year or adversely affect LVEF at 30 days. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
T J Carvalho Mendonca ◽  
L Patricio ◽  
M Oliveira ◽  
I Rodrigues ◽  
G Portugal ◽  
...  

Abstract Introduction Transcatheter aortic valve implantation (TAVI) is an established treatment in patients (P) with aortic stenosis. Despite the continuous developments of this procedure, high-grade conduction disturbances requiring permanent pacemaker (PPM) implantation is still a major and common complication of TAVI. Furthermore, long-term chronic right ventricular pacing has been associated with negative effects on ventricular function and heart failure (HF). Aim   to evaluate the long-term impact of PPM after TAVI focusing on mortality and HF hospitalization. Methods  We retrospectively examined P who underwent TAVI with a self-expanding valve from 2009 to 2018 at our institution. All P had pre-procedural clinical evaluation, including ECG, cardiac computed tomographic angiography and transthoracic echocardiography. P with previous PPM were excluded. Results  265P (57% male, mean age 81.4 years, 20% with left ventricular ejection fraction <40%) were analysed. Mean STS score and mean Euroscore II were 6.33% and 7.07%, respectively. Mean transvalvular gradient was 52.78 mmHg and mean aortic valve area 0.67 cm2. Forty-seven P (17%) underwent PPM implantation during the first 30 days after TAVI. P requiring PPM had higher prevalence of diabetes mellitus, chronic renal disease, atrial fibrillation and right bundle branch block. During a mean follow-up of 20.3 months, post-TAVI PPM was associated with similar mortality rate (29.8% vs. 25.6%, HR 1.28, 95% CI 0.72-2.29, p = 0.42) and similar cardiovascular mortality (9.8% vs. 6.4%, HR 0.72, 95% CI 0.21-2.4, p = 0.59) compared to P without PPM. There were no significant differences in HF hospitalization (4.9% vs. 2.4%, p = 0.47). Kaplan-Meier curves of total mortality and cardiovascular mortality according to the need for PPM post-TAVI were similar.  Conclusions  In P submitted to TAVI, PPM implantation is a relatively common finding, not associated with higher risk of total mortality, cardiovascular mortality or HF hospitalization in a long-term follow-up.