scholarly journals Management of degenerative changes and stenosis of the lumbar spinal canal secondary to cervical spinal cord injury

Spinal Cord ◽  
2003 ◽  
Vol 41 (4) ◽  
pp. 211-219 ◽  
Author(s):  
R Abel ◽  
H A Cerrel Bazo ◽  
P J Kluger ◽  
F Selmi ◽  
T Meiners ◽  
...  
1977 ◽  
Vol 47 (2) ◽  
pp. 290-292 ◽  
Author(s):  
Wolf I. Steudel ◽  
William Ingunza

✓ The authors describe a unique case in which a bullet was lodged in the spinal canal at the C2–3 level. The patient exhibited clinically the syndrome of acute central cervical spinal cord injury. The pathogenesis is discussed with reference to three similar cases in the literature.


Spine ◽  
1999 ◽  
Vol 24 (6) ◽  
pp. 605-613 ◽  
Author(s):  
Michael G. Fehlings ◽  
Sanjay C. Rao ◽  
Charles H. Tator ◽  
Ghassan Skaf ◽  
Paul Arnold ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1057
Author(s):  
Riccardo Bravi ◽  
Stefano Caputo ◽  
Sara Jayousi ◽  
Alessio Martinelli ◽  
Lorenzo Biotti ◽  
...  

Residual motion of upper limbs in individuals who experienced cervical spinal cord injury (CSCI) is vital to achieve functional independence. Several interventions were developed to restore shoulder range of motion (ROM) in CSCI patients. However, shoulder ROM assessment in clinical practice is commonly limited to use of a simple goniometer. Conventional goniometric measurements are operator-dependent and require significant time and effort. Therefore, innovative technology for supporting medical personnel in objectively and reliably measuring the efficacy of treatments for shoulder ROM in CSCI patients would be extremely desirable. This study evaluated the validity of a customized wireless wearable sensors (Inertial Measurement Units—IMUs) system for shoulder ROM assessment in CSCI patients in clinical setting. Eight CSCI patients and eight healthy controls performed four shoulder movements (forward flexion, abduction, and internal and external rotation) with dominant arm. Every movement was evaluated with a goniometer by different testers and with the IMU system at the same time. Validity was evaluated by comparing IMUs and goniometer measurements using Intraclass Correlation Coefficient (ICC) and Limits of Agreement (LOA). inter-tester reliability of IMUs and goniometer measurements was also investigated. Preliminary results provide essential information on the accuracy of the proposed wireless wearable sensors system in acquiring objective measurements of the shoulder movements in CSCI patients.


2021 ◽  
Vol 284 ◽  
pp. 103568
Author(s):  
Pauline Michel-Flutot ◽  
Arnaud Mansart ◽  
Therese B. Deramaudt ◽  
Isley Jesus ◽  
Kun-Ze Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document