Achievement of linear response for competitive bioaffinity assays of ligands: criteria of optimized interaction systems

RSC Advances ◽  
2016 ◽  
Vol 6 (112) ◽  
pp. 110858-110865 ◽  
Author(s):  
J. Pu ◽  
X. L. Hu ◽  
J. Liao ◽  
Y. W. Li ◽  
J. L. Qin ◽  
...  

For a linear response, an optimized competitive bioaffinity assay of a ligand requiresCRT> 3 ×CPT,CPT> 50 ×KdR, andKdR> 260 ×KdX(CRTandCPTare concentrations of the probe and protein whileKdXandKdRareKdfor the ligand and probe, respectively).

Author(s):  
Keinosuke Kobayashi

Equidensitometry as developed by E. Lau and W. Krug has been little used in the analysis of ordinary electron photomicrographs, yet its application to the high voltage electron images proves merits of this procedure. Proper sets (families) of equidensities as shown in the next page are able to reveal the contour map of mass thickness distribution in thick noncrystalline specimens. The change in density of the electron micrograph is directly related to the mass thickness of corresponding area in the specimen, because of the linear response of photographic emulsions to electrons and the logarithmic relation between electron opacity and mass thickness of amorphous object.This linearity is verified by equidensitometry of a spherical solid object as shown in Fig. 1a. The object is a large (1 μ) homogeneous particle of polystyrene. Fig. 1b is a composite print of three equidensities of the 1st order prepared from Fig. 1a.


2016 ◽  
Vol 545 ◽  
pp. 109-121 ◽  
Author(s):  
B Villazán ◽  
FG Brun ◽  
V González‑Ortiz ◽  
F Moreno‑Marín ◽  
TJ Bouma ◽  
...  

2020 ◽  
Vol 2020 (7) ◽  
pp. 143-1-143-6 ◽  
Author(s):  
Yasuyuki Fujihara ◽  
Maasa Murata ◽  
Shota Nakayama ◽  
Rihito Kuroda ◽  
Shigetoshi Sugawa

This paper presents a prototype linear response single exposure CMOS image sensor with two-stage lateral overflow integration trench capacitors (LOFITreCs) exhibiting over 120dB dynamic range with 11.4Me- full well capacity (FWC) and maximum signal-to-noise ratio (SNR) of 70dB. The measured SNR at all switching points were over 35dB thanks to the proposed two-stage LOFITreCs.


Author(s):  
Daniel Lambrecht ◽  
Eric Berquist

We present a first principles approach for decomposing molecular linear response properties into orthogonal (additive) plus non-orthogonal/cooperative contributions. This approach enables one to 1) identify the contributions of molecular building blocks like functional groups or monomer units to a given response property and 2) quantify cooperativity between these contributions. In analogy to the self consistent field method for molecular interactions, SCF(MI), we term our approach LR(MI). The theory, implementation and pilot data are described in detail in the manuscript and supporting information.


2018 ◽  
Vol 69 (2) ◽  
pp. 297-299
Author(s):  
Adriana Nita ◽  
Delia Mirela Tit ◽  
Lucian Copolovici ◽  
Carmen Elena Melinte (Frunzulica) ◽  
Dana Maria Copolovici ◽  
...  

The aim of this study was to develop and validate a rapid, accurate, and exact method for the quantitative determination of famotidine in pharmaceutical products. The HPLC analyses were performed by using a mobile phase containing methanol:1% acetic acid solution=30:7 (v/v), at a flow rate of 0.4 mL/min.The total time of the method was 10 min, and the retention time of famotidine was 4.16 min. The detection was evaluated at l=267 nm. The method has been validated by using different validation parameters. The linear response of the detector for famotidine peak area was observed at concentrations ranging from 0.1 to 0.0001 mg mL-1 , resulting in a correlation coefficient of 0.99998. The values of the detection limit and of the quantification limit are 0.00048 mg mL-1 and 0.00148 mg mL-1, respectively. The method proposed allowed accurate (with a relative error of less than 2%) and precise (RSD values less than 2.0%) determination of famotidine content in pharmaceutical products and can be used for its rapid quantitative analysis.


Toxins ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 604
Author(s):  
Zhong-Xing Rao ◽  
Mike D. Tokach ◽  
Jason C. Woodworth ◽  
Joel M. DeRouchey ◽  
Robert D. Goodband ◽  
...  

Fumonisin contamination in corn is an emerging issue in animal feed production. Fumonisin disrupts the metabolism of sphingolipids and reduces growth performance. This experiment was conducted to determine the effect of feeding fumonisin-contaminated corn on growth performance and sphinganine (SA) to sphingosine (SO) ratios of 9 to 28 kg pigs. A total of 350 pigs, were used with 5 pigs/pen and 14 pens/treatment. Dietary treatments contained fumonisin-contaminated corn (50 mg/kg of fumonisin B1 + B2) blended with low fumonisin corn (10 mg/kg of fumonisin B1 + B2) to provide dietary fumonisin concentrations of 7.2, 14.7, 21.9, 32.7, and 35.1 mg/kg. From day 0 to 28, increasing fumonisin concentration decreased (linear, p < 0.001) average daily gain, average daily feed intake (linear, p = 0.055), and gain:feed ratio (linear, p = 0.016). Although these response criteria tested linear, the greatest reduction in performance was in pigs fed with 32.7 and 35.1 mg/kg of fumonisin (B1 + B2). Increasing fumonisin concentration increased the serum SA:SO ratio (linear, p < 0.001) on day 14 and 28. In summary, for 9 to 28 kg nursery pigs, increasing fumonisin linearly decreased average daily gain and gain:feed ratio. However, despite the linear response, diets containing up to 21.9 mg/kg of fumonisin did not have as dramatic a decrease in growth performance as those fed more than 32.7 mg/kg. Further research is warranted to determine the effect of fumonisin concentrations between 21.9 and 32.7 mg/kg.


Trees ◽  
2012 ◽  
Vol 26 (4) ◽  
pp. 1389-1396 ◽  
Author(s):  
Yumei Zhou ◽  
Marcus Schaub ◽  
Lianxuan Shi ◽  
Zhongling Guo ◽  
Anan Fan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document