scholarly journals Parallel resonance type fault current limiting circuit breaker

High Voltage ◽  
2020 ◽  
Vol 5 (1) ◽  
pp. 76-82 ◽  
Author(s):  
Hamid Radmanesh ◽  
Seyed Hamid Fathi
2014 ◽  
Vol 556-562 ◽  
pp. 1959-1963
Author(s):  
Si Ming Wei ◽  
Yi Gong Zhang ◽  
Huan Liu ◽  
Zhi Qiang Dai ◽  
Xiao Du

It is great significance for development of MTDC (Multi-terminal HVDC) to build DC transmission and distribution grids. However, the relatively low impedance in DC grids makes the fault penetration much faster and deeper .Consequently, fast and reliable DC circuit breaker is needed to isolate faults. Breaking time and other parameters are important for a breaker to achieve its goals. This paper presents a DC circuit breaker with a current-limiting inductance and gets the rising and falling characteristics of fault current. Based on the characteristics, a design method of breaking time sequence will be given, as well as the calculation of current-limiting inductance and the selection principles of arresters. A 10kV DC distribution grid is modeled and simulated by PSCAD/EMTDC to verify that the method can meet the requirements of breaking fault current quickly and reliably.


Energies ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 4210
Author(s):  
Kang-Cheol Cho ◽  
Min-Ki Park ◽  
Sung-Hun Lim

Recently, a lot of interesting research has been conducted to solve the fault current problem of the DC system. In long-distance transmission, DC transmission is more economical than AC transmission. The connection of power grids with a DC system can also better control the power flow and provide high stability. However, the control of the fault current in a DC system is more difficult to handle than in an AC system because the DC system does not make a zero point, unlike the AC system. In addition, there is a disadvantage, in that an arc occurs when a circuit breaker operates. In this paper, a new type of DC superconducting fault current limiter (SFCL) is proposed. This new type of SFCL is composed of two superconducting elements, a current limiting resistor/reactor (CLR), and a transformer. With the proposed SFCL, the DC fault current limiting experiments were performed and the DC fault current limiting characteristics of this SFCL due to the component of the CLR were analyzed.


2016 ◽  
Vol 31 (1) ◽  
pp. 236-244 ◽  
Author(s):  
Hamid Radmanesh ◽  
S. H. Fathi ◽  
G. B. Gharehpetian ◽  
Amir Heidary

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4157
Author(s):  
Sang-Jae Choi ◽  
Jun-Hyup Lee ◽  
Jin-Wook Lee ◽  
Sung-Hun Lim

In this paper, direct current (DC) fault current limiting and interrupting operation of hybrid DC circuit breaker (DCCB) using double quench, which consists of DCCB, a series resonance circuit, power electronic switch, surge arrestor, two separated current limiting reactor/resistor, and two superconducting elements, were suggested. The suggested hybrid DCCB can perform the interrupting operation after twice or once DC fault current limiting operation according to DC fault current amplitude. To verify the effective operation of the suggested hybrid DCCB, the modeling for the components of DCCB, the surge arrestor, and the SCE was carried out and its DC operational characteristics were analyzed. Through the analysis of the modeling results for the suggested hybrid DCCB, the advantages of hybrid DCCB were discussed.


2021 ◽  
Author(s):  
Juheng Wang ◽  
Kun Dong ◽  
Jianfeng Zhao ◽  
Zhan Shi ◽  
Yue Yu ◽  
...  

2004 ◽  
Vol 124 (6) ◽  
pp. 843-850 ◽  
Author(s):  
Evenson Calixte ◽  
Yasunobu Yokomizu ◽  
Toshiro Matsumura ◽  
Hideki Fujita

Sign in / Sign up

Export Citation Format

Share Document