scholarly journals Rotor angle stability control for DFIG-integrated power system considering phase-amplitude characteristics of transient-grid voltage

2019 ◽  
Vol 13 (16) ◽  
pp. 3549-3555 ◽  
Author(s):  
Di Zheng ◽  
Jinxin Ouyang ◽  
Xiaofu Xiong ◽  
Mengyang Li
Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 5023
Author(s):  
Ashish Shrestha ◽  
Francisco Gonzalez-Longatt

With the increasing penetration rate of Power Electronic Converter (PEC) based technologies, the electrical power systems are facing the problem of transient stability since the PEC based technologies do not contribute to the system inertia, and the proportion of synchronous generators (i.e., the source of inertia) is in decreasing rate. In addition, PEC based technologies’ components have poor inherent damping. It is very important to analyze the system characteristics of a power system to minimize the potential instabilities during the contingencies. This paper presents the parametric sensitivity analysis of the rotor angle stability indicators for the 39-bus New England power system. The indicators of rotor angle stability analysis such as critical fault clearing time (CCT), Eigenvalue points, damping ratio, frequency deviation, voltage deviation, and generator’s speed deviation are identified and analyzed for three case scenarios; each scenario has six sub-cases with different inertia constants. The results show that the CCTs for each component will be reduced if the inertia reduces at any section of a multi-machine power system. Although the applied three scenarios with six sub-cases are identified to be stable in this analysis, the decreasing inertia constant has significant impact on the power system dynamics.


Author(s):  
Nur Ashida Salim ◽  
Mohamad Salehan Ab. Samah ◽  
Hasmaini Mohamad ◽  
Zuhaila Mat Yasin ◽  
Nur Fadilah Ab Aziz

<span lang="EN-GB">The aim of this research is to anticipate the stability status of a power system when the system is exposed to a change in frequency and rotor angle due to small disturbances. The proposed study was implemented on the IEEE Reliability Test System 1979 (IEEE RTS-79) which contains 24 buses, 38 transmission lines and 32 generators. Steady state stability limit of a system refers to the maximum amount of power that is permissible through the system without loss of its steady state stability. This research proposes the development of a Graphical User Interface (GUI) to observe the frequency and rotor angle stability due to the effect of small disturbances using the One Machine Infinite Bus (OMIB) technique. This proposed technique could ease the power system utility especially the power system operation to observe and examine the system frequency and rotor angle stability due to small disturbances. The findings from this research has proven that the proposed technique to observe the frequency and rotor angle stability due to small disturbances has successfully been developed using a GUI.</span>


Sign in / Sign up

Export Citation Format

Share Document