scholarly journals Voltage control method based on three‐phase four‐wire sensitivity for hybrid AC/DC low‐voltage distribution networks with high‐penetration PVs

Author(s):  
Lu Zhang ◽  
Chunxue Zhao ◽  
Bo Zhang ◽  
Gen Li ◽  
Wei Tang
Author(s):  
Klara Janiga

Deterioration of voltage conditions is one of the frequent consequences of connecting an increasing number of photovoltaic sources to the low-voltage (LV) power grid. Under adverse conditions, i.e. low energy consumption and high insolation, microgeneration can cause voltage surges that violate acceptable limits. Research shows that the increase in voltage is the main limitation for connecting new energy microsources to the LV network and forces the reconstruction of the network. An alternative to costly modernizations can be the implementation of appropriate strategies for controlling network operation to maintain the voltage at the required level. The article presents an overview of the methods and concepts of voltage control in a low-voltage network developed so far to mitigate the undesirable phenomenon of voltage boosting. The focus was mainly on local methods—not requiring communication infrastructure—as best suited to the conditions of Polish distribution networks. Gathering the results of many tests and simulations carried out in different conditions and on different models allowed for the formulation of general conclusions and can be a starting point for further research on a control method that can be widely used in the national power system.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2754
Author(s):  
Mengmeng Xiao ◽  
Shaorong Wang ◽  
Zia Ullah

Three-phase imbalance is a long-term issue existing in low-voltage distribution networks (LVDNs), which consequently has an inverse impact on the safe and optimal operation of LVDNs. Recently, the increasing integration of single-phase distributed generations (DGs) and flexible loads has increased the probability of imbalance occurrence in LVDNs. To overcome the above challenges, this paper proposes a novel methodology based on the concept of "Active Asymmetry Energy-Absorbing (AAEA)" utilizing loads with a back-to-back converter, denoted as “AAEA Unit” in this paper. AAEA Units are deployed and coordinated to actively absorb asymmetry power among three phases for imbalance mitigation in LVDNs based on the high-precision, high-accuracy, and real-time distribution-level phasor measurement unit (D-PMU) data acquisition system and the 5th generation mobile networks (5G) communication channels. Furthermore, the control scheme of the proposed method includes three control units. Specifically, the positive-sequence control unit is designed to maintain the voltage of the DC-capacitor of the back-to-back converter. Likewise, the negative-sequence and zero-sequence control units are expected to mitigate the imbalanced current components. A simple imbalanced LVDN is modeled and tested in Simulink/Matlab (MathWorks, US). The obtained results demonstrate the effectiveness of the proposed methodology.


2021 ◽  
Vol 4 (S2) ◽  
Author(s):  
Marika Nakamura ◽  
Shinya Yoshizawa ◽  
Hideo Ishii ◽  
Yasuhiro Hayashi

AbstractAs the number of photovoltaic (PV) power generators connected to the distribution grid increases, applications of on-load tap changers (OLTCs), power conditioning systems, and static reactive power compensators are being considered to mitigate the problem of voltage violation in low voltage distribution systems. The reactive power control by power conditioning systems and static reactive power compensators can mitigate steep voltage fluctuations. However, it creates losses in generation opportunities. On the other hand, OLTCs are installed at the bases of distribution lines and can collectively manage the entire system. However, the conventional voltage control method, i.e., the line drop compensation (LDC) method, is not designed for the case in which a large number of PV systems are installed in the distribution network, which results in voltage violations above the limit of the acceptable range. This study proposes a method to determine the optimal LDC control parameters of the voltage regulator, considering the power factor of PV systems to minimize the magnitude of voltage violations based on the voltage profile analysis of low-voltage (LV) distribution networks. Specifically, during a measurement period of several days, the voltages at some LV consumers and pole transformers were measured, and the optimal parameters were determined by analyzing the collected data. The effectiveness of the proposed method was verified through a numerical simulation study using the actual distribution system model under several scenarios of PV penetration rates. Additionally, the difference in the effectiveness of voltage violation reduction was verified in the case where all the LV consumer’s consumer voltage data measured per minute were used as well as in the case where only the maximum and minimum values of the data within the measurement period were used. The results reveal that the proposed method, which operates within the parameters determined by the voltage analysis of the LV distribution network, is superior to the conventional method. Furthermore, it was found that even if only the maximum and minimum values of the measurement data were used, an effective voltage violation reduction could be expected.


2021 ◽  
Vol 72 (6) ◽  
pp. 356-365
Author(s):  
Jordan Radosavljević

Abstract High penetration of photovoltaic (PV) generation in low voltage (LV) distribution networks can leads some power quality problems. One of the most important issues in this regard is the impermissible voltage deviation in periods with a large imbalance between PV generation and local load consumption. Accordingly, many authors deal with this issue. This work investigates voltage regulation for LV distribution networks equipped with the hybrid distribution transformer (HDT), and with high penetration of PV units. A two-stage algorithm for voltage regulation is proposed. In the first stage, a local (distributed) voltage control is performed by minimizing the injection power of the PV-battery storage system (BS)-local load entity at the common bus. In the second stage, optimal coordination is performed between the HDT and the local voltage control. In fact, the second stage is an optimal voltage regulation problem. The aim is to minimize the voltage deviations at load buses by optimal settings the voltage support of the HDT. A PSO algorithm is used to solve this optimization problem. the proposed approach is implemented in MATLAB software and evaluated on the IEEE european LV test feeder.


Sign in / Sign up

Export Citation Format

Share Document