scholarly journals Advanced voltage control method for improving the voltage quality of low-voltage distribution networks with photovoltaic penetrations

2021 ◽  
Vol 4 (S2) ◽  
Author(s):  
Marika Nakamura ◽  
Shinya Yoshizawa ◽  
Hideo Ishii ◽  
Yasuhiro Hayashi

AbstractAs the number of photovoltaic (PV) power generators connected to the distribution grid increases, applications of on-load tap changers (OLTCs), power conditioning systems, and static reactive power compensators are being considered to mitigate the problem of voltage violation in low voltage distribution systems. The reactive power control by power conditioning systems and static reactive power compensators can mitigate steep voltage fluctuations. However, it creates losses in generation opportunities. On the other hand, OLTCs are installed at the bases of distribution lines and can collectively manage the entire system. However, the conventional voltage control method, i.e., the line drop compensation (LDC) method, is not designed for the case in which a large number of PV systems are installed in the distribution network, which results in voltage violations above the limit of the acceptable range. This study proposes a method to determine the optimal LDC control parameters of the voltage regulator, considering the power factor of PV systems to minimize the magnitude of voltage violations based on the voltage profile analysis of low-voltage (LV) distribution networks. Specifically, during a measurement period of several days, the voltages at some LV consumers and pole transformers were measured, and the optimal parameters were determined by analyzing the collected data. The effectiveness of the proposed method was verified through a numerical simulation study using the actual distribution system model under several scenarios of PV penetration rates. Additionally, the difference in the effectiveness of voltage violation reduction was verified in the case where all the LV consumer’s consumer voltage data measured per minute were used as well as in the case where only the maximum and minimum values of the data within the measurement period were used. The results reveal that the proposed method, which operates within the parameters determined by the voltage analysis of the LV distribution network, is superior to the conventional method. Furthermore, it was found that even if only the maximum and minimum values of the measurement data were used, an effective voltage violation reduction could be expected.

2013 ◽  
Vol 448-453 ◽  
pp. 2097-2104
Author(s):  
Jun Li ◽  
Lin Zhang ◽  
Mei Juan Liu ◽  
Ge Xin Xing ◽  
Wei Wei Li ◽  
...  

SVG can compensate reactive power deficiency, suppress harmonics, improve three-phase imbalance and power quality more flexibly. There are very few small volume SVG products available for low voltage distribution network in the past. The generic SVG products are very expansive, thus not suitable for low voltage distribution network. Therefore, it is an urgent task to design a new generation distribution network SVG product that offers good value for money. This paper studied a SVG digital controller based on TMS320F28335 DSP chip. The fast and powerful computing and parallel operation capability of TMS320F28335 can satisfy the real-time, multifunction and multiple objective coordination control of SVG. Applied the instantaneous reactive power theory and adopted current direct control mode, an enhanced filtering algorithm to filter instantaneous sampling value is proposed. Automatic bi-directional compensation control strategy effectively reduced voltage variation at the user side. Its effectiveness is verified by an engineering project.


Author(s):  
Prof. Amruta Bijwar, Prof. Madhuri Zambre

Nowadays low voltage distribution network is considered as worldwide future generation distribution network. But the major concern is harmonics generation and steps taken to cancel those harmonics. In our proposed work, low voltage distribution network is designed with low voltage and harmonics are cancelled in our method. The combination of current control unit and voltage control unit will give extra reliable power solution to increase the required capacity of low voltage grids. The high voltage protection gears are used in worst environment for low voltage and low current distribution network test is preferable to assess a variety of operation uniqueness. Therefore, it has few restrictions in implementation of economic in addition to process methodologies. In our work a 48V direct current base up-scale low voltage distribution network test is urbanized to allow the copy and surveillance of a variety of phenomenon of direct current distribution networks. The proposed system provide stretchy pattern ability by introduce S-connectors and T-connectors module that will be proscribed distantly, and near real time monitor function through by means of a data acquisition system associated toward the nodes. Each connector be able to calculate Power, Voltage and current with up to 250 kHz frequency. To calculate power quality and to understand the performance of the distribution network, frequency analysis is required along with collected data.


Electrician ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 33
Author(s):  
Osea Zebua ◽  
Noer Soedjarwanto ◽  
Jemi Anggara

Intisari — Stabilitas tegangan telah menjadi perhatian yang penting dalam operasi jaringan distribusi tenaga listrik. Ketidakstabilan tegangan dapat menyebabkan kerusakan pada peralatan-peralatan listrik bila terjadi dalam waktu yang lama. Makalah ini bertujuan untuk merancang dan membuat peralatan deteksi stabilitas tegangan jangka panjang pada jaringan tegangan rendah. Sensor tegangan dan sensor arus digunakan untuk memperoleh data tegangan dan arus. Mikrokontroler Arduino digunakan untuk memproses perhitungan deteksi stabilitas tegangan jangka panjang dari data tegangan yang diperoleh dari sensor. Hasil deteksi kondisi stabilitas tegangan ditampilkan dengan indikator lampu led. Hasil pengujian pada jaringan distribusi tegangan rendah tiga fasa menunjukkan bahwa peralatan dapat mendeteksi gangguan stabilitas tegangan jangka panjang secara online dan dinamis.Kata kunci — Deteksi, stabilitas tegangan jangka panjang, jaringan distribusi tegangan rendah. Abstract — Voltage stability has become important concern in the operation of electric power distribution networks. Voltage instability can cause damage to electrical equipments if it occurs for a long time. This paper aims to design and build long-term voltage stability detection equipment on low-voltage network. Voltage sensors and current sensors are used to obtain voltage and current data. The Arduino microcontroller is used to process calculation of long-term voltage stability detection from data obtained from the sensors. The results of detection of voltage stability conditions are displayed with the LED indicators. Test result on three-phase low-voltage distribution network shows that equipment can detect long–term voltage stability disturbance online and dynamically.Keywords— Detection, long-term voltage stability, low-voltage distribution network.


Author(s):  
Ivan Nadtoka ◽  
◽  
Pyotr Osadchiy ◽  
Vladimir Tropin ◽  
◽  
...  

The features of applying the «open triangle» scheme in the structure of a rural low-voltage distribution network with a voltage of 220 V are studied from the standpoint of achieving a certain energy efficiency. The energy effect is estimated by the criterion of the relative value of the additional power losses in the conductors of a three-wire line of a 220 V network caused by reactive power and load asymmetry. The load is modeled by two power receivers connected to the phase-to-phase voltage, the general output of the power receivers is grounded, which forms the «open triangle» circuit. The energy characteristics of the active load, active load with capacitive corrective element, active load with capacitive and inductive corrective elements are analyzed; and also the most practical case – active-inductive load with various values of reactive power factors -0,1; 0,2; 0,3 and capacitive corrective element. An important feature of applying the «open triangle» scheme in the structure of a rural low-voltage distribution network with a voltage of 220 V, from the standpoint of achieving practically necessary and sufficient energy efficiency - not exceeding 10 % of the additional power losses, is the ability to compensate for reactive power and balancing the phase currents of the network line using only one corrective capacitor of relatively low power - about 50 % of the active power of one power receiver.