scholarly journals Simulation of wind power plant with double-fed machine when operating in autonomous system in parallel with synchronous commensurable power generator

2020 ◽  
Vol 178 ◽  
pp. 01034
Author(s):  
Rauf Mustafayev ◽  
Laman Hasanova

Autonomous system, containing synchronous generators in a classic design, driven by either diesel or gas turbine, which operates in parallel with a wind power plant (WPP) containing an asynchronous double-fed machine (ADFM) through external network, is considered in the paper. At the same time, the power transmission scheme and the corresponding equivalent circuit are also drawn up. The equations of the synchronous generator and the external network are written in the axes rotating at the speed of the synchronous generator rotor, and the equations of the WPP’s generator in the axes rotating at the speed of its rotor. By means of “docking” equations a digital model of the entire system is compiled with the external network parameters and loads on the side of the synchronous generator and WPP’s asynchronous generator, which are represented by constant-conductivity shunts. Static and dynamic characteristics of the system are calculated.

2020 ◽  
Vol 1 (2) ◽  
pp. 229-233
Author(s):  
Nila Gusriani ◽  
Muldi Yuhendri

Wind power is a type of renewable energy power plant that is starting to develop in Indonesia. This plant uses wind turbines to convert wind power into mechanical power that will drive the generator. The generators used in this wind power plant have limited capabilities. In order to prevent operation that exceeds the capacity of the generator, it is necessary to monitor and protect the components of the wind power generator. This study proposes a wind power generator monitoring system using the Arduino MKR 1000 based on the Matlab Graphical User Interface (GUI). Wind power plant parameters that are monitored are wind speed, turbine rotation speed and generator output power. The tool made was tested on a wind power plant in the laboratory that uses a horizontal axis wind turbine with a permanent magnet type generator. The test results show that the wind power generator monitoring system made in this study has worked well. This can be seen from the wind speed data, the turbine rotation speed and the generator output power data displayed on the monitoring screen in accordance with the data available on the measuring instrument.


2021 ◽  
Author(s):  
Rakesh R ◽  
Shruthi R Gunaga ◽  
Rashmi Ugare ◽  
Sushma R ◽  
Chaitra CP ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document