scholarly journals Safety analysis of energy storage station based on DFMEA

2021 ◽  
Vol 236 ◽  
pp. 01006
Author(s):  
Xin Li ◽  
Qingshan Wang ◽  
Yan Chen ◽  
Yan Li ◽  
Zhenyu He ◽  
...  

In order to ensure the normal operation and personnel safety of energy storage station, this paper intends to analyse the potential failure mode and identify the risk through DFMEA analysis method, and then through the targeted treatment of potential risk items, formulate effective design prevention countermeasures and personnel emergency measures, so as to improve the energy storage station. The reliability of the battery can reduce the safety risk and ensure the safe operation of energy storage station.

2021 ◽  
Vol 30 (1) ◽  
pp. 677-688
Author(s):  
Zhenzhuo Wang ◽  
Amit Sharma

Abstract A recent advent has been seen in the usage of Internet of things (IoT) for autonomous devices for exchange of data. A large number of transformers are required to distribute the power over a wide area. To ensure the normal operation of transformer, live detection and fault diagnosis methods of power transformers are studied. This article presents an IoT-based approach for condition monitoring and controlling a large number of distribution transformers utilized in a power distribution network. In this article, the vibration analysis method is used to carry out the research. The results show that the accuracy of the improved diagnosis algorithm is 99.01, 100, and 100% for normal, aging, and fault transformers. The system designed in this article can effectively monitor the healthy operation of power transformers in remote and real-time. The safety, stability, and reliability of transformer operation are improved.


2021 ◽  
Author(s):  
Binkai Jiang ◽  
Mingyi Qiu ◽  
Lingdong Kong ◽  
Yanxing Cai ◽  
Xing Lei ◽  
...  

2012 ◽  
Vol 166-169 ◽  
pp. 1072-1075
Author(s):  
Ying Ming Zhou ◽  
Zhi Min Song ◽  
Hai Feng Zhao ◽  
Shu Yun Mi

With the characteristics of low noise, low vibration, high reliability and long life, Screw Compressor is the indispensable main equipment which widely used in petrochemical field. The abnormal vibration of Compressor will affect normal operation of the host, lead to damage of some main parts such as Compressor and motor and at the same time it’s an unneglectable hidden trouble for equipment’s safe operation. This article takes the data acquisition of vibration and the analyses of shake for two Ammonia Refrigeration Piston Compressors, and study at the reason about shock then take the effective shockproof treatment plan. All these ensure the stable running of the facility.


2013 ◽  
Vol 373-375 ◽  
pp. 1345-1348 ◽  
Author(s):  
Zong Jiang Mu ◽  
Yan Xu ◽  
Shao Bo Yan

Power plant relay protection setting value of the hidden harm causes of relay protection device is not correct, safe and stable operation of the power plant. In this paper, from the angle of the safe operation of power plant, the hidden danger to plant with the protection setting is studied and then the risk evaluation method of power plant relay protection setting values of hidden trouble is proposed. From the power plant relay protection setting value considering two aspects of probability and consequences of potential outbreak of different values, value potential risk is considered, and of a certain power plant in Hubei was made the risk assessment and analysis, in order to verify the theoretical rationality and accuracy.


Sign in / Sign up

Export Citation Format

Share Document