The Dome C: A unique site for high-contrast imaging and extrasolar planet searching with a large telescope

2005 ◽  
Vol 14 ◽  
pp. 291-296 ◽  
Author(s):  
O. Lardière ◽  
M. Carbillet ◽  
A. Riccardi ◽  
P. Salinari ◽  
C. Aime
2018 ◽  
Vol 615 ◽  
pp. A92 ◽  
Author(s):  
R. Galicher ◽  
A. Boccaletti ◽  
D. Mesa ◽  
P. Delorme ◽  
R. Gratton ◽  
...  

Context. The consortium of the Spectro-Polarimetric High-contrast Exoplanet REsearch installed at the Very Large Telescope (SPHERE/VLT) has been operating its guaranteed observation time (260 nights over five years) since February 2015. The main part of this time (200 nights) is dedicated to the detection and characterization of young and giant exoplanets on wide orbits. Aims. The large amount of data must be uniformly processed so that accurate and homogeneous measurements of photometry and astrometry can be obtained for any source in the field. Methods. To complement the European Southern Observatory pipeline, the SPHERE consortium developed a dedicated piece of software to process the data. First, the software corrects for instrumental artifacts. Then, it uses the speckle calibration tool (SpeCal) to minimize the stellar light halo that prevents us from detecting faint sources like exoplanets or circumstellar disks. SpeCal is meant to extract the astrometry and photometry of detected point-like sources (exoplanets, brown dwarfs, or background sources). SpeCal was intensively tested to ensure the consistency of all reduced images (cADI, Loci, TLoci, PCA, and others) for any SPHERE observing strategy (ADI, SDI, ASDI as well as the accuracy of the astrometry and photometry of detected point-like sources. Results. SpeCal is robust, user friendly, and efficient at detecting and characterizing point-like sources in high contrast images. It is used to process all SPHERE data systematically, and its outputs have been used for most of the SPHERE consortium papers to date. SpeCal is also a useful framework to compare different algorithms using various sets of data (different observing modes and conditions). Finally, our tests show that the extracted astrometry and photometry are accurate and not biased.


Author(s):  
Uwe Lücken ◽  
Michael Felsmann ◽  
Wim M. Busing ◽  
Frank de Jong

A new microscope for the study of life science specimen has been developed. Special attention has been given to the problems of unstained samples, cryo-specimens and x-ray analysis at low concentrations.A new objective lens with a Cs of 6.2 mm and a focal length of 5.9 mm for high-contrast imaging has been developed. The contrast of a TWIN lens (f = 2.8 mm, Cs = 2 mm) and the BioTWTN are compared at the level of mean and SD of slow scan CCD images. Figure 1a shows 500 +/- 150 and Fig. 1b only 500 +/- 40 counts/pixel. The contrast-forming mechanism for amplitude contrast is dependent on the wavelength, the objective aperture and the focal length. For similar image conditions (same voltage, same objective aperture) the BioTWIN shows more than double the contrast of the TWIN lens. For phasecontrast specimens (like thin frozen-hydrated films) the contrast at Scherzer focus is approximately proportional to the √ Cs.


2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Shangfeng Wang ◽  
Yong Fan ◽  
Dandan Li ◽  
Caixia Sun ◽  
Zuhai Lei ◽  
...  

2004 ◽  
Author(s):  
Alessandro Berton ◽  
Raffaele G. Gratton ◽  
Markus Feldt ◽  
Silvano Desidera ◽  
Elena Masciadri ◽  
...  

2012 ◽  
Author(s):  
Jiangpei Dou ◽  
Deqing Ren ◽  
Yongtian Zhu ◽  
Xi Zhang ◽  
Rong Li

Sign in / Sign up

Export Citation Format

Share Document