scholarly journals Characterization and localization of partial-discharge-induced pulses in fission chambers designed for sodium-cooled fast reactors

2018 ◽  
Vol 170 ◽  
pp. 03002
Author(s):  
G. Galli ◽  
H. Hamrita ◽  
C. Jammes ◽  
M.J. Kirkpatrick ◽  
E. Odic ◽  
...  

During the operation of the Superphenix and Phenix reactors, an aberrant electrical signal was detected from the fission chambers used for neutron flux monitoring. This signal, thought to be due to partial electrical discharge (PD) is similar to the signal resulting from neutron interactions, and is generated in fission chambers at temperatures above 400 °C. This paper reports work on the characterization and localization of the source of this electrical signal in a High Temperature Fission Chamber (HTFC). The relation between the shape of the PD signal and various parameters (nature and pressure of the chamber filling gas, electrode gap distance, and fission chamber geometry) are first described. Next, experiments designed to identify the location within the chambers where the PD are being generated are presented. After verification and refinement of the results of these localization studies, it should be possible to propose changes to the fission chamber in order to reduce or eliminate the PD signal.

Author(s):  
Luigi Lepore ◽  
Romolo Remetti ◽  
Mauro Cappelli

Although Sodium Fast Reactors (SFRs) are the most investigated solutions for the future fast-flux facilities so far, Lead Fast Reactors (LFRs) promise to be a very competitive alternative thanks to their peculiarity concerning coolant-safety, fuel cycle and waste management. Nevertheless, the development of LFRs presents today some drawbacks still to be solved. Due to the harder neutron flux, the current instrumentation developed for SFRs is likely to be extended to LFRs as a first attempt. Otherwise, new monitoring instrumentation could be developed in order to assure more tailored results. Different measurement technologies can be considered for fast flux monitoring and flux absolute measurements in order to provide a reliable and quick calibration of the overall reactor neutron instrumentation. The goal of this paper is to study the validity of typical fast reactor fission chamber designs (e.g. SuperPhénix fission chambers), indicating which are the limitations when used in a LFR environment. Afterwards, alternative detector solutions with enhanced sensitivity and response will be proposed.


Author(s):  
P. M. Vijayakumaran ◽  
C. P. Nagaraj ◽  
C. Paramasivan Pillai ◽  
R. Ramakrishnan ◽  
M. Sivaramakrishna

The nuclear instrumentation systems of the Prototype Fast Breeder Reactor (PFBR) primarily comprise of global Neutron Flux Monitoring, Failed Fuel Detection & Location, Radiation Monitoring and Post-Accident Monitoring. High temperature fission chambers are provided at in-vessel locations for monitoring neutron flux. Failed fuel detection and location is by monitoring the cover gas for fission gases and primary sodium for delayed neutrons. Signals of the core monitoring detectors are used to initiate SCRAM to protect the reactor from various postulated initiating events. Radiation levels in all potentially radioactive areas are monitored to act as an early warning system to keep the release of radioactivity to the environment and exposure to personnel well below the permissible limits. Fission Chambers and Gamma Ionisation Chambers are located in the reactor vault concrete for monitoring the neutron flux and gamma radiation levels during and after an accident.


Author(s):  
Luigi Lepore ◽  
Romolo Remetti ◽  
Mauro Cappelli

Among GEN IV projects for future nuclear power plants, lead-cooled fast reactors (LFRs) seem to be a very interesting solution due to their benefits in terms of fuel cycle, coolant safety, and waste management. The novelty of this matter causes some open issues about coolant chemical aspects, structural aspects, monitoring instrumentation, etc. Particularly, hard neutron flux spectra would make traditional neutron instrumentation unfit to all reactor conditions, i.e., source, intermediate, and power range. Identification of new models of nuclear instrumentation specialized for LFR neutron flux monitoring asks for an accurate evaluation of the environment the sensor will work in. In this study, thermal hydraulics and chemical conditions for the LFR core environment will be assumed, as the neutron flux will be studied extensively by the Monte Carlo transport code MCNPX (Monte Carlo N-Particles X-version). The core coolant’s high temperature drastically reduces the candidate instrumentation because only some kinds of fission chambers and self-powered neutron detectors can be operated in such an environment. This work aims at evaluating the capabilities of the available instrumentation (usually designed and tailored for sodium-cooled fast reactors) when exposed to the neutron spectrum derived from the Advanced Lead Fast Reactor European Demonstrator, a pool-type LFR project to demonstrate the feasibility of this technology into the European framework. This paper shows that such a class of instrumentation does follow the power evolution, but is not completely suitable to detect the whole range of reactor power, due to excessive burnup, damages, or gamma interferences. Some improvements are possible to increase the signal-to-noise ratio by optimizing each instrument in the range of reactor power, so to get the best solution. The design of some new detectors is proposed here together with a possible approach for prototyping and testing them by a fast reactor.


2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Hanane Arahmane ◽  
El-Mehdi Hamzaoui ◽  
Rajaa Cherkaoui El Moursli

We present an overview of fission chamber’s functioning modes, theoretical aspects of the nonnegative matrix factorization methods, and the opportunities that offer neutron data processing in order to achieve neutron flux monitoring tasks. Indeed, it is a part of research project that aimed at applying Blind Source Separation methods for in-core and ex-core neutron flux monitoring while analyzing the outputs of fission chamber. The latter could be used as a key issue for control, fuel management, safety concerns, and material irradiation experiments. The Blind Source Separation methods had been used in many scientific fields such as biomedical engineering and telecommunications. Recently, they were used for gamma spectrometry data processing. The originality of this research work is to apply these powerful methods to process the fission chamber output signals. We illustrated the effectiveness of this tool using simulated fission chamber signals.


2004 ◽  
Vol 47 (1) ◽  
pp. 36-38
Author(s):  
S. S. Parzhitskii ◽  
A. P. Kobzev ◽  
Yu. P. Popov ◽  
N. A. Gundorin ◽  
I. A. Oprya ◽  
...  

2020 ◽  
Vol 225 ◽  
pp. 03006
Author(s):  
G. de Izarra ◽  
B. Geslot ◽  
S. Bréaud ◽  
A. Pepino ◽  
J-F. Villard ◽  
...  

Since many years, the Instrumentation, Sensors and Dosimetry laboratory at CEA Cadarache has been working to propose innovative and robust design of fission chambers. In this framework, few simulation tools like Chester or PyFc were developed to make detector prototyping and optimisation possible. Up to now, the code experimental validations are scarce mainly because of the lack of flexibility of regular fission chambers. In order to set up an experimental database for code validation, an innovative modular twin fission chamber, the CFTM, was designed. It allows to set with precision the inter-electrode gap, the filling gas pressure as well as the fissile deposit used. This detector was irradiated in Minerve zero power reactor in order to gather results for code validation. Thanks to a calibration procedure, a bank of experimental results is available for simulation validation.


2018 ◽  
Vol 65 (9) ◽  
pp. 2412-2420 ◽  
Author(s):  
G. Galli ◽  
H. Hamrita ◽  
C. Jammes ◽  
M. J. Kirkpatrick ◽  
E. Odic ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document