scholarly journals Assessment of impact of borehole heat exchanger design on heat extraction/rejection efficiency

2016 ◽  
Vol 75 ◽  
pp. 09009 ◽  
Author(s):  
V.F. Gornov ◽  
N.V. Peskov ◽  
G.P. Vasilyev ◽  
M.V. Kolesova
2021 ◽  
Vol 169 ◽  
pp. 738-751
Author(s):  
Ji Li ◽  
Wei Xu ◽  
Jianfeng Li ◽  
Shuai Huang ◽  
Zhao Li ◽  
...  

2021 ◽  
Author(s):  
Giorgia Dalla Santa ◽  
Simonetta Cola ◽  
Antonio Galgaro

<p>In closed-loop Ground Source Heat Pump system, the circulation of a heat-carrier fluid into the heat exchanger provides the thermal exchange with the underground.</p><p>In order to improve the heat extraction from the ground, the fluid temperature is often lowered down to subzero temperatures; as a consequence, the thermal alteration induced in the ground is more intense and can cause freezing processes in the surroundings. In sediments with significant clay fraction, the inner structure and the pore size distribution are irreversibly altered by freezing-thawing cycles.</p><p>A wide laboratory program has been performed in order to measure the induced deformations and the permeability variations under different conditions of mechanical loads/depth [1], interstitial water salinity [2] and soil plasticity [3]. In addition, vertical deformations and permeability variations induced by freeze-thaw cycles have been measured also in Over-Consolidated silty clays at different OCR [4].</p><p>The results suggest that, despite the induced frozen condition is quite confined close to the borehole [5], in Normal-Consolidated silty clay layers the freezing-thawing-cycles induce an irreversible settlement up to 16%, gathered cycle-after cycle depending on sediment plasticity, pore fluid salinity and applied load. In addition, despite the overall contraction of the soil, the vertical hydraulic conductivity may increase by about 8 times due to a remarkable modification of the soil fabric with increases in pore size, pores connectivity and orientation [6].</p><p>The OC silty-clays show an opposite behavior. Experimental results point out that, in case of OC deposits, higher the OCR lower the freeze-thaw induced settlement. In case of OCR > 15, the settlement turns to a slight expansion. Conversely, the observed augment in vertical permeability increases with the OCR degree [4].</p><p>These occurrences are significant and irreversible and could affect the functionality of the system as well as lead to environmental effects such as local settlements, negative friction on the borehole heat exchangers or interconnection among aquifers in the probe surroundings.</p><ul><li>[1]. Dalla Santa G*, Galgaro A, Tateo F, Cola S (2016). Modified compressibility of cohesive sediments induced by thermal anomalies due to a borehole heat exchanger. <strong>Engineering Geology</strong> 202, 143-152.</li> <li>[2]. Dalla Santa G*, Galgaro A, Tateo F, Cola S (2016). Induced thermal compaction in cohesive sediments around a borehole heat exchanger: laboratory tests on the effect of pore water salinity. <strong>Environmental Earth Sciences</strong>, 75(3), 1-11.</li> <li>[3]. Cola S, Dalla Santa G, Galgaro A (2020). Geotechnical hazards caused by freezing-thawing processes induced by borehole heat exchangers. <strong>Lecture Notes in Civil Engineering</strong>, 40, pp. 529–536</li> <li>[4]. Dalla Santa G, Cola S, Galgaro A (2021). Deformation and Vertical Permeability Variations Induced by Freeze-Thaw Cycles in Over-Consolidated Silty Clays. <strong>Challenges and Innovations in Geomechanics</strong>, 117</li> <li>[5]. Dalla Santa G*, Farina Z, Anbergen H, Rühaak W, Galgaro A (2019). A Comparative Study on the Relevance of Computing Freeze-Thaw Effects for Borehole Heat Exchanger Modelling. <strong>Geothermics</strong> 79, 164-175.</li> <li>[6]. Dalla Santa G*, Cola S, Secco M, Tateo F, Sassi R, Galgaro A (2019). Multiscale analysis of freeze-thaw effects induced by ground heat exchangers on permeability of silty-clays. <strong>Geotechnique</strong> 2019, 69(2).</li> </ul>


2021 ◽  
Author(s):  
Jan Niederau ◽  
Johanna Fink ◽  
Moritz Lauster

<p>The actual heat demand of a building depends on various building-specific parameters, such as building age, insulation type, housing volume, but also external parameters, e.g. outdoor temperature. Being able to dynamically model the thermal power demand of a specific building can increase the robustness of coupled borehole heat exchanger simulations (BHE-simulations), as the transient heat demand models of a building / consumer can be used to simulate the thermal response of the subsurface to the prescribed consumer demand.</p><p>We present results of coupling results of Building Performance Simulation (BPS) with simulations of Borehole Heat Exchangers. BPS are carried out using TEASER (Tool for Energy Analysis and Simulation for Efficient Retrofit) which models the thermal power demand of a building based on parameters, such as year of construction, net-lease area, and outdoor-temperature.</p><p>Using annual temperature curves, we model the thermal power demand of buildings from the 1950s, once in original state and in retrofitted state. The thermal response of a connected BHE-field is simulated using SHEMAT-Suite, an open-source simulator for heat- and mass-transfer in porous media. In our BHE simulations, thermal plumes develop as a result of heat-extraction and regional groundwater flow.</p><p>To improve the forecast of, e.g. the magnitude of these plumes, realistic knowledge of the heat demand is important, which can be achieved by the presented coupling of BPS- and BHE-modelling.</p><p><span> </span></p>


Energy ◽  
2018 ◽  
Vol 164 ◽  
pp. 1298-1310 ◽  
Author(s):  
Xianzhi Song ◽  
Gaosheng Wang ◽  
Yu Shi ◽  
Ruixia Li ◽  
Zhengming Xu ◽  
...  

2021 ◽  
Vol 289 ◽  
pp. 116590
Author(s):  
Wanlong Cai ◽  
Fenghao Wang ◽  
Shuang Chen ◽  
Chaofan Chen ◽  
Jun Liu ◽  
...  

Author(s):  
Tomislav Kurevija ◽  
Adib Kalantar ◽  
Marija Macenić ◽  
Josipa Hranić

When considering implementation of shallow geothermal energy as a renewable source for heating and cooling of the building, special care should be taken in hydraulic design of borehole heat exchanger system. Laminar flow can occur in pipes due to usage of glycol mixture at low temperature or inadequate flow rate. This can lead to lower heat extraction and rejection rates of the exchanger because of higher thermal resistances. Furthermore, by increasing flow rate to achieve turbulent flow and satisfactory heat transfer rate can lead to increase the pressure drop of the system and oversizing of circulation pump which leads to impairment of seasonal coefficient of performance at the heat pump. Most frequently used borehole heat exchanger system in Europe is double-loop pipe system with smooth inner wall. Lately, development is focused on implementation of different configuration as well as with ribbed inner wall which ensures turbulent flow in the system, even at lower flow rates. At a location in Zagreb, classical and extended thermal response test was conducted on three different heat exchanger configurations in the same geological environment. With classic TRT test, thermogeological properties of the ground and thermal resistance of the borehole were determined for each smooth or turbulator pipe configuration. Extended Steady-State Thermal Response Step Test (TRST) was implemented, which incorporate series of power steps to determine borehole extraction rate at the define steady-state heat transfer conditions of 0/-3°C. Results show that heat exchangers with ribbed inner pipe wall have advantages over classic double-loop smooth pipe design, in terms of greater steady state heat extraction rate and more favorable hydraulic conditions.


Sign in / Sign up

Export Citation Format

Share Document