scholarly journals Measurement of currents and voltages non-sinusoidal parameters in power supply systems with rectifier load

2018 ◽  
Vol 245 ◽  
pp. 06007 ◽  
Author(s):  
Valery Vanin ◽  
Alexandr Bulychov ◽  
Maxim Popov ◽  
Olga Vasilyeva ◽  
Maria Shakhova

The use of frequency-controlled electric drives in industry and municipal services is accompanied by the problem of their negative impact on the distribution network. As examples, the results of measurements of power quality indices in the power supply system of an oil producing enterprise and on the supply input of a railway traction substation are given. It is shown that the voltage subgroup total harmonic distortions (THDS) can exceed their rated permitted values in 100% of the measurement time.

Author(s):  
Hitoshi Hayashiya ◽  
Norio Koguchi ◽  
Hiroshi Yamamoto ◽  
Takashi Ozaki ◽  
Takashi Sakurai ◽  
...  

Author(s):  
V. Stepanenko ◽  
Y. Veremiichuk

The implementation of an integrated energy supply system is an effective way to increase energy efficiency, reduce CO2 emissions and increase the use of renewable energy, as well as provide opportunities for energy production, conversion and storage in interconnected infrastructures for energy system operators and consumers. Also, increasing the level of energy efficiency of the energy supply system is one of the important strategies to slow down the growth of demand and mitigate the negative impact on health, the economy and the environment. The article considers the integrated use of energy, the introduction of energy hubs as part of future energy networks and proposes a schematic diagram of an integrated energy supply system. The article presents the results of modeling and computational experiment of ventilation and air conditioning systems in the integrated power supply system, taking into account the technical and operational characteristics of SES, regulatory and technical documents and building codes. According to the results of the study, it is established that the schedule of SES generation and the schedule of electricity consumption by ventilation and air conditioning systems are similar, which leads to a reduction in operating costs and a reduction in the load on the building's power supply system. The scientific substantiation of the integration of the energy storage system into the energy supply structure has been further developed, which will ensure the reliability of the power supply and the efficiency of the solar power plant.


2014 ◽  
Vol 1006-1007 ◽  
pp. 955-961
Author(s):  
Xing Wang Li ◽  
Ju Rui Yang

Continuous co-phase traction power supply system is the major change of the traction power supply. It is important to analyze the transient response characteristics of overhead contact line for the traction substation feeder protection. This article introduces the main structure of continuous co-phase traction power supply system and the control strategy of traction substation. Meanwhile, transient responses of overhead contact line in the earth short circuit are studied, including metallic earth short circuit and non-metallic earth short circuit (high resistance ground). In the PSCAD/EMTDC electromagnetic transient simulation environment, the effects on the system and the recovery process are studied which the fault occurred in the output interface of traction substation and occurred in overhead contact line.


2011 ◽  
Vol 204-210 ◽  
pp. 1675-1678
Author(s):  
Guo Wang ◽  
Ming Xing Tian ◽  
En En Ren ◽  
Li Na Ding

Traction load in electrified railway result in the power supply system contains a lot of negative sequence, harmonic and reactive current. It is necessary to analysis the compensation principle based on active compensation of electrified railway traction power supply system. According to the relation between primary winding and secondary winding of regular traction transformer, we deduced general voltage and general current transform formula, and then deduced completely and negative sequence compensation formulas. It also gives the method of reduce active compensation capacity.


2014 ◽  
Vol 1055 ◽  
pp. 312-315
Author(s):  
Xue Wu Li ◽  
Peng Xiao Ji

Revamping of electrified railway traction power supply is to improve the railway transport capacity and important measures to promote the development of national economy. As a result of the traction power supply voltage was higher, the simulation technology was applied to modification of the traction power supply system. For the development of research workers to reduce risk and funding has become an international practice. Traction power supply system and the modeling and simulation of the traction power supply capacity technology are discussed in detail. It points out the simulation technology in the development direction of expansion engineering in the application of traction power supply.


2020 ◽  
Vol 79 (3) ◽  
pp. 139-144
Author(s):  
E. P. Figurnov ◽  
Yu. I. Zharkov ◽  
N. A. Popova

When calculating short circuit currents in the traction network, it is necessary to take into account the input resistance of the traction substation, including the resistance of the transformers of the substation and the resistance of the power supply system. The input resistance during short circuit is determined based on the equivalent circuit of the external power supply system, of which this traction substation is an integral part. Traditionally equivalent circuit of a three-phase system has the form of a star, in which the resulting resistances in each phase are connected in series with a source of phase electromotive force, and these sources have a common point. Another equivalent circuit in the form of a triangle is possible, in which on each side the resulting resistances are connected in series with the source of linear electromotive force. It is important to note that neither one nor the other type of equivalent circuit is determined by the connection scheme of the transformer windings of the traction substation. It is only necessary to take into account the absence of a circuit for zero sequence currents. All elements of the equivalent circuit, as is known, should be brought to uniform basic conditions. If the parameters of these elements are expressed in named units, then the basic values are the effective voltage values of the main stage and the rated power of the power transformer of the traction substation. If the components of one and the other equivalent circuits are reduced to one stage of the operating voltage, for example 27.5 kV, then for the same elements of the power supply system, the resistance values in the equivalent circuit in the form of a triangle are three times larger than in the equivalent circuit in the form of a star. In this case, the input resistances of the traction substation for the one and the other equivalent circuits are absolutely identical. Therefore, in the calculation of short circuit currents of the traction network, you can use any of these equivalent circuits of the power supply system and traction substation. Formulas for calculating the resistances of the elements of the power supply system and electrical installations, given in the standards, manuals and reference books, relate to the equivalent circuit of the short circuit in the form of a star. When using an equivalent circuit in the form of a triangle, these resistances must first be tripled, and then divided by three when calculating the short-circuit currents. The meaninglessness of such an operation is obvious. The equivalent circuit of the traction substation and the external power supply system in the form of a triangle when calculating short circuits in the traction network has no advantages compared to the traditional equivalent circuit in the form of a star. The information on the linear currents on the primary and secondary windings of the traction substation transformer during a short circuit in the traction network is given, which is necessary to select the settings of its relay protection kit.