A Comparison of Trans-Articular Screw versus Dorsal Bridge Plate versus Compression Locking Plate Fixation in B2 Lis Franc Injuries: a 5 Year Experience in a Level 1 Trauma Centre, in the United Kingdom

Author(s):  
V Kommalapti ◽  
C Wek ◽  
D Coffey ◽  
T Hardwick ◽  
I Reichert ◽  
...  
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Fu Wang ◽  
Yan Wang ◽  
Jinye Dong ◽  
Yu He ◽  
Lianxin Li ◽  
...  

Abstract Background and hypothesis The typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column. Materials and methods We performed an anatomical study and reported 8 cases of proximal humerus fractures with unstable medial columns treated with plate fixation through a minimally invasive anterolateral approach and medial approach. All surgeries were performed by the same single surgeon. Patients were followed clinically and radiographically at 1, 3, 6, and 12 months postoperatively. Results There was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head, or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10° in any direction), screw cutout, nonunion, or deep infection occurred. Conclusions The combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.


Injury ◽  
2011 ◽  
Vol 42 (4) ◽  
pp. 408-413 ◽  
Author(s):  
Robert C. Sproul ◽  
Jaicharan J. Iyengar ◽  
Zlatko Devcic ◽  
Brian T. Feeley

2013 ◽  
Vol 39 (7) ◽  
pp. 745-754 ◽  
Author(s):  
A. Bentohami ◽  
K. de Burlet ◽  
N. de Korte ◽  
M. P. J. van den Bekerom ◽  
J. C. Goslings ◽  
...  

The purpose of this systematic review is to assess the prevalence of complications following volar locking plate fixation of distal radial fractures. A computer-based search was carried out using EMBASE and PUBMED/MEDLINE. Only prospective comparative and prospective cohort studies that presented data concerning complications after treatment of distal radial fractures with a volar locking plate in human adults with a minimal follow-up of 6 months were included. Two quality assessment tools were used to assess the methodological quality of the studies (level of evidence rating according to the Oxford Centre of Evidence Based Medicine and the modified version of the Cochrane Bone, Joint and Muscle Trauma Group’s former quality assessment tool). Thirty three studies were eligible for final assessment. Most complications were problems with nerve and tendon function as well as complex regional pain syndrome. With an overall complication rate of 16.5%, most of which were ‘minor’ complications and low rates of nonunion and malunion, volar locking plate fixation can be considered a reasonably safe treatment option for patients with distal radial fractures.


Hand ◽  
2016 ◽  
Vol 11 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Ismar Dizdarevic ◽  
Claire M. Eden ◽  
Matthew Bengard ◽  
O. Alton Barron ◽  
Louis W. Catalano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document