The Effect of the Additional Use of Grommets in Silicone Implant Arthroplasty of the Metacarpophalangeal Joints

1999 ◽  
Vol 24 (5) ◽  
pp. 561-564 ◽  
Author(s):  
K. SCHMIDT ◽  
R. WILLBURGER ◽  
A. OSSOWSKI ◽  
R. K. MIEHLKE

After silicone arthroplasty of the metacarpophalangeal (MP) joint there is increasing osteolysis, subsidence and fracture of the implants in the longer postoperative term. In 44 patients with rheumatoid arthritis (54 hands) 151 arthroplasties of the metacarpophalangeal joint were assessed at a mean of 3.9 years postoperatively. In 57 arthroplasties titanium protectors (grommets) were used. There were no significant differences in the clinical outcomes with respect to swelling, correction of ulnar deviation, range of active movement and grip strength. The additional use of grommets in MP joint arthroplasty slightly reduced reactive osteolysis, protected the spacers from breakage and slightly reduced the amount of pain with only a few additional complications in the midterm follow-up.

2010 ◽  
Vol 35 (9) ◽  
pp. 746-753 ◽  
Author(s):  
P.B. Honkanen ◽  
R. Thonen ◽  
E.T. Skyttä ◽  
M. Ikävalko ◽  
M.U.K. Lehto ◽  
...  

It was hypothesized that the bioresorbable interposition implant might offer a viable alternative to conventional silicone implant arthroplasty in rheumatoid metacarpophalangeal joint destruction. A randomized clinical study was performed to compare a stemless poly-L/D-lactide copolymer 96: 4 (PLDLA) implant with the Swanson silicone implant. Results in 52 patients (53 hands and 175 joints) at a mean follow-up of 2 years (minimum 1 year) showed that the improvement in clinical assessments was comparable in both groups, except for better maintenance of palmar alignment in the Swanson group. The lack of implant fractures and intramedullary osteolysis were advantages of the PLDLA implant. The bioresorbable PLDLA interposition implant may offer an alternative tool for tailored reconstruction of rheumatoid metacarpophalangeal joints.


2017 ◽  
Vol 06 (04) ◽  
pp. 294-300 ◽  
Author(s):  
Avanthi Mandaleson ◽  
Michael Wagels ◽  
Stephen Tham

Background The combination of trapeziometacarpal arthritis and intercarpal pattern of degenerative wrist arthritis is uncommon. Purpose To report on the clinical and radiologic results of patients who have undergone radial column excision (scaphoidectomy and trapeziectomy) (RCE) and four-corner fusion (4CF). We describe the patterns of disease that present with basal thumb and midcarpal arthritis and treatment outcomes of a single-surgeon series. Patients and Methods A consecutive series of seven patients underwent RCE and 4CF over a 2-year period, for basal thumb osteoarthritis with concurrent degenerative midcarpal wrist arthritis. Six patients were available for review. All six patients were women with a mean age of 73 years (range: 67–78; SD 4.6). Mean follow-up time was 48.2 months (34–59 months). Radiographic and clinical outcomes were recorded for all patients, to include wrist range of motion, key pinch, grip strength, and patient-rated wrist evaluation (PRWE). Results There were no failures or revision procedures. The mean range of motion was flexion of 40 degrees (range: 30–40 degrees), extension of 30 degrees (range: 20–42 degrees), radial deviation of 18 degrees (range: 10–30 degrees), and ulnar deviation of 15 degrees (range: 0–25 degrees). The mean key pinch was 4.2 kg (range: 0.5–10, SD ± 3.5) and mean grip strength was 9.4 kg (range: 0–19, SD ± 8.9). The PRWE results in four patients were within normal values. Conclusion RCE with 4CF resulted in acceptable clinical outcomes in four of six patients treated, with no failures at a mean follow-up of 48.2 months. Level of Evidence Level IV, therapeutic study.


Hand Surgery ◽  
2009 ◽  
Vol 14 (01) ◽  
pp. 25-29 ◽  
Author(s):  
Katsumitsu Arai ◽  
Hajime Ishikawa ◽  
Takehiro Murai ◽  
Junichi Fujisawa ◽  
Naoto Endo

We report a case of a patient with rheumatoid arthritis undergoing revision surgery 30 years after primary metacarpophalangeal joint arthroplasty using a Swanson implant. Removal and replacement of the implant were successfully performed, and the patient was satisfied with the revision surgery.


2005 ◽  
Vol 30 (1) ◽  
pp. 8-13 ◽  
Author(s):  
K. MÖLLER ◽  
C. SOLLERMAN ◽  
M. GEIJER ◽  
P. KOPYLOV ◽  
M. TÄGIL

The results of Swanson and Avanta metacarpophalangeal joint arthroplasties in rheumatoid patients were compared in a prospective, randomized study of 30 patients (120 implants). At 2-year follow-up, grip strength was measured, hand function was assessed with the Sollerman test and the subjective outcome was determined with visual analogue scores. With both implants ulnar deviation and flexion deformities decreased, and there was no difference between the groups. The increase in range of motion was 7° greater with Avanta implants than with Swanson implants. Grip strength and hand function were unaltered but the visual analogue scales showed decreased pain levels and subjective improvements in hand function, grip strength and cosmesis. Twenty-four of 30 patients were satisfied. Fracture of the silicone spacer occurred with 12 Avanta (20%) and eight Swanson implants (13%), with a higher fracture frequency in men.


1994 ◽  
Vol 19 (4) ◽  
pp. 479-484 ◽  
Author(s):  
M. LANZETTA ◽  
T. J. HERBERT ◽  
W. B. CONOLLY

Silicone implant arthroplasty is, arguably, the most effective treatment for the majority of patients with symptomatic arthritis in the hand and wrist. In 1985 the problem of silicone synovitis was first brought to our attention. Since that time there have been numerous reports on this condition leading to a worldwide trend against the use of silicone implants. However, the true incidence and effects of silicone synovitis have not been clearly defined. For this reason, we have undertaken a survey of all patients who have undergone silicone implant arthroplasty in the wrist and hand in our Unit between 1975 and 1990. Patients with rheumatoid arthritis and those undergoing MP or IP joint arthroplasty were excluded. Of the 289 implant arthroplasties remaining, we have been able to review personally 229 implants with a mean follow-up of 3.8 years (range 1–15). Although 40% of cases showed significant radiological changes, only 11 patients (4.8%) developed symptoms requiring treatment. Of these, two were managed conservatively whilst the rest underwent revision surgery, all with entirely satisfactory results. We conclude that silicone implant arthroplasty remains the treatment of choice for patients with painful joint disease in the hand and wrist.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 491.2-491
Author(s):  
M. Tada ◽  
Y. Yamada ◽  
K. Mandai ◽  
N. Hidaka

Background:We previously reported that the prevalence of sarcopenia was 28% in patients with rheumatoid arthritis (RA) in a cohort study 1. RA patients have a high risk of falls and fractures 2. However, the predictors of falls and fractures in RA patients are not known.Objectives:Whether evaluation of muscle mass and function at baseline could predict falls and fractures during four-year follow-up was investigated.Methods:The four-year follow-up data from a prospective, observational study (CHIKARA study: Correlation researcH of sarcopenIa, sKeletal muscle and disease Activity in Rheumatoid Arthritis) were used. Muscle mass was measured by a body impedance analyzer, and leg muscle mass was calculated. The leg muscle score (max: 100, min: 0) reflected the ratio of leg muscle mass to overall weight. Grip strength as an indicator of muscle function was evaluated using a digital, hand-held, isokinetic dynamometer. The correlations between muscle mass or function and falls or fractures were analyzed by survival rates and Cox hazard ratios. Leg muscle mass and grip strength were investigated by receiver operating characteristic (ROC) curve analysis for correlations with falls or fractures.Results:A total of 100 RA patients (female: 78%, mean age: 66.1 years) were enrolled; 35 patients had falls, and 19 patients had fractures during the four-year follow-up. The leg muscle score, grip strength, age, and fractures at baseline were significantly correlated with falls. The cut-off values of the leg muscle score and grip strength were calculated to be 84.5 points (sensitivity: 0.79, specificity: 0.43) and 15.9 kg (sensitivity: 0.56, specificity: 0.70), respectively, by ROC curve analysis. The patients were divided into four groups by their leg muscle scores and grip strength; the numbers of falls and fractures are shown in Table 1 for each group. The fall-free survival rate was significantly lower in the group with low leg muscle score and low grip strength (35.3%) than in the other groups (P=0.002) (Figure 1). The hazard ratio for the both low group was significantly increased, 3.6-fold (95%CI: 1.1-11.5), compared to that in the both high group.Table 1.Numbers of falls and fractures by category of leg muscle score and grip strengthLG + GS+(n=34)LG - GS+(n=12)LG + GS-(n=37)LG - GS-(n=17)P value*Falls, N6515110.010Fractures, N34660.072LG+: leg muscle score >84.5 points, GS+: grip strength >15.9kg, LG-: leg muscle score ≤84.5 points, GS+: grip strength ≤15.9kg*: compared in four groups by Kruskal-Walls test.Figure 1.Fall-free survival rate in the four groupsConclusion:RA patients with both low leg muscle score and low grip strength at baseline were at high risk for falls during the four-year follow-up period. Evaluation of muscle mass and function can predict falls in RA patients.References:[1]Tada, M., Yamada, Y., Mandai, K. & Hidaka, N. Matrix metalloprotease 3 is associated with sarcopenia in rheumatoid arthritis - results from the CHIKARA study. Int J Rheum Dis21, 1962-1969, doi:10.1111/1756-185X.13335 (2018).[2]van Staa, T. P., Geusens, P., Bijlsma, J. W., Leufkens, H. G. & Cooper, C. Clinical assessment of the long-term risk of fracture in patients with rheumatoid arthritis. Arthritis Rheum54, 3104-3112, doi:10.1002/art.22117 (2006).Disclosure of Interests:None declared


HAND ◽  
1978 ◽  
Vol os-10 (1) ◽  
pp. 77-81 ◽  
Author(s):  
A. R. M. Upton ◽  
J. Darracott ◽  
F. A. Bianchi

Summary A loss of functional motor axons in the median and ulnar nerves occurred in half of thirty-three patients with rheumatoid arthritis. Weakness of small hand muscles may predispose to the development of ulnar deviation of the fingers in patients with joint disease at the radio-ulnar and metacarpophalangeal joints. There is no evidence that spasm of small hand muscles is a significant cause of ulnar deviation of the fingers in rheumatoid arthritis. Ulnar deviation of the fingers in rheumatoid arthritis is not due to selective impairment of the ulnar nerve or the deep palmar branch of the ulnar nerve even though ulnar deviation of the fingers can occur in association with such lesions and in the absence of joint disease.


2015 ◽  
Vol 40 (10) ◽  
pp. 1956-1962 ◽  
Author(s):  
David R. Dickson ◽  
Ravi Badge ◽  
David Nuttall ◽  
Adam C. Watts ◽  
Sumedh C. Talwalkar ◽  
...  