scholarly journals Comparison of EUS-guided tissue acquisition using two different 19-gauge core biopsy needles: a multicenter, prospective, randomized, and blinded study

2015 ◽  
Vol 03 (05) ◽  
pp. E471-E478 ◽  
Author(s):  
John DeWitt ◽  
Chang-Min Cho ◽  
Jingmei Lin ◽  
Mohammad Al-Haddad ◽  
Marcia Canto ◽  
...  
2014 ◽  
Vol 79 (5) ◽  
pp. AB110 ◽  
Author(s):  
John M. Dewitt ◽  
Jinmei Lin ◽  
Mohammad a. AL-Haddad ◽  
Marcia I. Canto ◽  
Ashley Salamone ◽  
...  

2015 ◽  
Vol 81 (5) ◽  
pp. AB545
Author(s):  
Se Woo Park ◽  
Moon Jae Chung ◽  
Jeong Youp Park ◽  
Seung Woo Park ◽  
SI. Young Song ◽  
...  

PLoS ONE ◽  
2016 ◽  
Vol 11 (5) ◽  
pp. e0154401 ◽  
Author(s):  
Se Woo Park ◽  
Moon Jae Chung ◽  
Sang Hoon Lee ◽  
Hee Seung Lee ◽  
Hyun Jik Lee ◽  
...  

2017 ◽  
Vol 85 (5) ◽  
pp. 1017-1024 ◽  
Author(s):  
Manu K. Nayar ◽  
Bharat Paranandi ◽  
Muhammad F. Dawwas ◽  
John S. Leeds ◽  
Antony Darne ◽  
...  

2016 ◽  
Vol 15 (6) ◽  
pp. 749-758 ◽  
Author(s):  
Thomas Wimmer ◽  
Govindarajan Srimathveeravalli ◽  
Mikhail Silk ◽  
Sebastien Monette ◽  
Narendra Gutta ◽  
...  

Objectives: To test the feasibility of modified biopsy needles as probes for irreversible electroporation ablation and periprocedural biopsy. Methods: Core biopsy needles of 16-G/9-cm were customized to serve as experimental ablation probes. Computed tomography-guided percutaneous irreversible electroporation was performed in in vivo porcine kidneys with pairs of experimental (n = 10) or standard probes (n = 10) using a single parameter set (1667 V/cm, ninety 100 µs pulses). Two biopsy samples were taken immediately following ablation using the experimental probes (n = 20). Ablation outcomes were compared using computed tomography, simulation, and histology. Biopsy and necropsy histology were compared. Results: Simulation-suggested ablations with experimental probes were smaller than that with standard electrodes (455.23 vs 543.16 mm2), although both exhibited similar shape. Computed tomography (standard: 556 ± 61 mm2, experimental: 515 ± 67 mm2; P = .25) and histology (standard: 313 ± 77 mm2, experimental: 275 ± 75 mm2; P = .29) indicated ablations with experimental probes were not significantly different from the standard. Histopathology indicated similar morphological changes in both groups. Biopsies from the ablation zone yielded at least 1 core with sufficient tissue for analysis (11 of the 20). Conclusions: A combined probe for irreversible electroporation ablation and periprocedural tissue sampling from the ablation zone is feasible. Ablation outcomes are comparable to those of standard electrodes.


2020 ◽  
Vol 39 (11) ◽  
pp. 2133-2142
Author(s):  
Per Thunswärd ◽  
Anders Nilsson ◽  
Håkan Ahlström

Sign in / Sign up

Export Citation Format

Share Document