Response To Infusion Of Polyelectrolyte Fractionated Human Factor VIII Concentrate In Human Haemophilia A

1981 ◽  
Author(s):  
P B A Kernoff ◽  
R S Lane ◽  
S Middleton ◽  
E G D Tuddenham

Plasma fractionation using polyelectrolytes (PEs) has potential advantages which include simplicity of procedure, high product purity, increased yield and removal of hepatitis viruses. The purpose of this study was to assess the in-vivo response to PE-fractionated human factor VIII concentrate (PE VIII) given to 3 volunteers with severe haemophilia A. PE VIII fractionated from bulk cryo- precipitate had a high specific activity (6.74 u/mg protein), no detectable isoagglutinins, a low fibrinogen content, high ratio of VIII coagulant activity (VIII:C)to VIII-related antigen (VIIIR:Ag), and a ratio of VIII:C to VIII coagulant antigen (VIII:CAg) of approximate unity. Single infusions, each of about 2000 i.u.(25 - 40 i.u./kg), were administered i.v. over 10 mins. There were no clinical, haematological or biochemical adverse effects during the 48 hr. post-infusion observation period. Immediate post-infusion recoveries of VIII:C were 119, 102 and 70 per cent with late phase half disappearance times of 17, 19 and 17 hours respectively. These values were similar to those obtained after infusion of intermediate-purity factor VIII concentrate to the same patients, and are in accord with the results of previous studies using conventional concentrates. PE VIII has potential as a therapeutic material for patients with haemophilia A.

1977 ◽  
Author(s):  
Jessica H. Lewis ◽  
Ute Hasiba ◽  
Joel A. Spero

Human factor VIII corrects the clotting defect in dog hemophilic plasma in vitro. The present studies were undertaken to see if this happened in vivo and to look for and document the development of an inhibitor. Four hemophiliac dogs were infused with factor VIII concentrates, the first two on five occasions, the others three times. Factor VIII:C, VIIIR:Ag (defined with antibody to human VIII) and VIIIR:vW were followed at pre, 10 minutes, 2 and 24 hours post infusion. The pre-infusion VIII:C (assayed with human substrate) averaged 0.23 U/ml compared to 6.93 U/ml for normal dogs; VIIIR:Ag was absent in both. VIIIR:vW was low but variable. Following the first injection, all four dogs responded in VIII:C about as calculated. The amounts of VIIIR:Ag and vW were much greater than VIII:C in the concentrates and in the post-first infusion samples from the dogs. On subsequent infusions rises in VIIIR:Ag were not detected and increases in VIII:C and VIIIR:vW were minimal. Precipitating anti-human VIII was found on the third infusion and thereafter. After the first infusion reactions were marked. Vomiting and diarrhea occurred in all, and one dog died in anaphylactic shock about one hour after the third infusion. Lack of response in VIIIR:Ag occurred before anti-VIII could be demonstrated in vitro. This rapid development of an inhibitor suggests that prolonged cross-species VIII therapy will not be successful. The ability of the precipitating anti-VIII elicited in the dogs to destroy VIII:C, VIIIR:Ag and VIIIR:vW is analagous to the in vitro effects of heterologous anti-VIIIs (rabbit and goat).


Haemophilia ◽  
2003 ◽  
Vol 9 (2) ◽  
pp. 157-163 ◽  
Author(s):  
P. J. M. Vossebeld ◽  
M. H. Tissing ◽  
H. M. Van Den Berg ◽  
F. W. G. Leebeek ◽  
A. De Goede-Bolder ◽  
...  

1988 ◽  
Vol 59 (03) ◽  
pp. 364-371 ◽  
Author(s):  
Odile Mejan ◽  
Vincent Fert ◽  
Maryléne Delezay ◽  
Michel Delaage ◽  
Rose Cheballah ◽  
...  

SummaryIn this study we describe a process for immunopurification of FVIII/vWF complex directly from plasma. A mAb against vWF has been selected that is able to bind, under physiologic conditions, the FVIII/vWF complex and to release it in slightly alkaline conditions while preserving its activity.After investigating the influence of solid supports and of coupling methods on the recovery of active FVIII we produced an immunoadsorbent by immobilisation of the selected mAb onto a Sephacryl S-1000 support using a benzoquinone coupling method. With this immunoadsorbent we developed a purification process directly from plasma with an excellent recovery (50%) of both FVIII and vWF activities. The product obtained is very enriched (the FVIII: C specific activity is 20 IU/mg of protein) and is stable after lyophilization.


Blood ◽  
1984 ◽  
Vol 63 (1) ◽  
pp. 31-41 ◽  
Author(s):  
PB Kernoff ◽  
ND Thomas ◽  
PA Lilley ◽  
KB Matthews ◽  
E Goldman ◽  
...  

Circulating antibodies to factor VIII (anti-VIII, “inhibitors”) occurring in patients with hemophilia neutralize porcine factor VIII less readily than human factor VIII in vitro. Over an 18-mo period, 8 patients with anti-VIII were treated with 45 courses (297 infusions) of polyelectrolyte-fractionated porcine factor VIII concentrate (PE porcine VIII). Where no anti-PE porcine VIII was detectable, mean post- infusion rise in plasma factor VIII was 1.29 U/dl/units infused/kg. Above 13 Old Oxford units of anti-PE porcine VIII and 48 Bethesda units of anti-human VIII, there were no postinfusion rises in plasma factor VIII. Where postinfusion rises were detected, clinical responses were good and conventional methods could be used to guide dosage. Ten percent of infusions were followed by febrile reactions, but these were usually mild and decreased in frequency and severity with increasing exposure. Multiple and prolonged courses of therapy were given to some patients without evidence of loss of clinical or laboratory efficacy. PE porcine VIII could provoke anamnestic rises of anti-VIII in susceptible patients, but appeared to have a lower immunogenic potential than human VIII. PE porcine VIII is a rational and effective therapeutic alternative for patients with anti-VIII, particularly those with intermediate level inhibitors who cannot be managed effectively using human factor VIII.


Blood ◽  
2000 ◽  
Vol 95 (5) ◽  
pp. 1594-1599 ◽  
Author(s):  
Hengjun Chao ◽  
Lan Mao ◽  
Andrew T. Bruce ◽  
Christopher E. Walsh

Persistent therapeutic levels of human factor VIII (hFVIII) would signify a major advance in the treatment of hemophilia A. Here we report sustained expression of hFVIII in immunocompetent mice using recombinant adeno-associated virus (rAAV) vectors. AAV can stably transduce liver cells, the target tissue for efficient hFVIII production. Because of rAAV packaging constraints, we tested 2 constructs using small regulatory elements designed for liver-specific transgene expression linked to B-domain–deleted hFVIII (BDD-hFVIII) cDNA. More than 1012/mL rAAV/BDD-hFVIII virion particles were generated using a transfection scheme that eliminates adenovirus. Coatest and APTT assays confirmed the production of functional BDD-hFVIII protein after transduction of 293 and HepG2 cells. In vivo experiments were performed in C57BL/6 and NOD/scid mice receiving 1010–11 rAAV/hFVIII particles via portal vein injection. All C57BL/6 mice tested developed anti-hFVIII antibody. In contrast, NOD/scid mice expressed hFVIII reaching 27% of normal human plasma levels. As expected, we could not detect hFVIII antigen from plasma samples isolated from control animals receiving equivalent doses of rAAV expressing enhanced green fluorescent protein (EGFP). Transgene mRNA expression was detected primarily in the liver and histologic analysis of the liver revealed no pathologic abnormalities. These results demonstrate a promising approach for treatment of hemophilia A.


1999 ◽  
Vol 82 (08) ◽  
pp. 562-571 ◽  
Author(s):  
Steven Josephs ◽  
Jiemin Zhou ◽  
Xiangming Fang ◽  
Ramón Alemany ◽  
Cristina Balagué ◽  
...  

IntroductionHemophilia A and B are the most common bleeding disorders caused by deficiencies of clotting factors VIII and IX, respectively, both of which are X-linked with a recessive heredity.1 Replacement of the deficient factors with frequent intravenous injections of plasma concentrates or recombinant proteins is the standard treatment for these diseases.2 Great efforts have been made for nearly a decade toward developing experimental gene therapy for these diseases and aiming at the development of a medical intervention that is more effective and convenient than the currently available replacement therapies.3 Hemophilia is a suitable clinical model for the development of gene therapy products and has a number of advantages: 1) there is a simple and well defined cause-and-effect relationship between the protein deficiencies and bleeding symptoms; 2) tissue-specific expression and precise regulation of the transgenes are not necessary; 3) well characterized animal models are available for preclinical studies; 4) an unequivocal endpoint for product efficacy can be assessed in clinical trials; and 5) even 1% to 5% of the normal physiological levels of the proteins is therapeutic.For gene therapy of hemophilia, the most challenging hurdle, with respect to the long-term expression of the deficient proteins at adequate levels, is the development of a suitable gene delivery system. Technologies have been evolving from ex vivo to in vivo approaches, from initial use of retroviral vector to recent application of adenviral (Ad) or adeno-associated virus (AAV) vector, demonstrating progress from early results of transient low-level expression to more sustained high-level expression.3 For hemophilia A treatment, Ad vectors are particularly useful, since the liver naturally produces factor VIII, and following intravenous (i.v.) injection, Ad vectors concentrate in the liver. This makes the gene transduction efficiency to liver very high. Adenovirus vectors have been developed for gene therapy due to their high titer, broad infectivity, potential for large payload, and in vivo gene delivery capacity.4 Although the immunogenicity and cytotoxicity associated with the early-generation Ad vectors have been a concern with respect to their clinical application, newly developed vectors, in which the viral coding sequences have been deleted, have significantly reduced the side effects associated with the vectors. The “gutless” Ad vector, or so called helper-dependent, large-capacity, or mini- Ad vectors are the representative examples of these new-generation Ad vectors.5-15 The mini-Ad vector system described in this report was developed based on two major research findings. First, an Ad- SV40 hybrid virus discovered during attempts to grow human Ad in non-permissive monkey COS-7 cells.16 The hybrid virus had a genome structure in which only both ends of the Ad sequences were retained and almost all coding sequences of the Ad genome were replaced by symmetric, tandemly repeated SV40 genomes. The hybrid viruses replicated and were packaged in the presence of a wild-type Ad as a helper. This finding implied that total replacement of the Ad genome was possible to form a mini-Ad vector as long as proper helper function and selective pressure was provided. Secondly, it was discovered that Ad packaging can be attenuated by deleting portions of the packaging signal.17 This finding provided a means to put selective pressure on the helper Ad (referred to as ancillary Ad) by specifically limiting its packaging process and allowing a preferential packaging of the mini-Ad. The system, therefore, is designed to have three main components: the mini-Ad vector, the E1-deleted ancillary Ad, and a production cell line that provides AdE1 complementation.Based on the mini-Ad vector system, MiniAdFVIII was developed. The MiniAdFVIII vector carries a 27 kb expression cassette, in which the full-length human factor VIII cDNA is flanked by a human albumin promoter and cognate genomic sequences. Infection of MiniAdFVIII in vitro showed that the vector mediated expression of functional human factor VIII at levels of 100-200 ng/106 cells per 24 hours in HepG2 and 293 cells. With single-dose intravenous injection of 1011 viral particles in hemophilic mice, MiniAdFVIII produced a sustained high-level expression of human factor VIII (at 100-800 ng/ml for up to 369 days) that corrected the factor VIII-deficient phenotype. Safety studies of MiniAdFVIII showed that there were no significant toxicities in mice and dogs after a single intravenous dose of up to 3×1011 and 6×1012 viral particles, respectively. In this report, other studies for developing the MiniAdFVIII vector with a site-specific integration capability and the development of a human factor VIII-tolerized mouse model for preclinical studies of MiniAdFVIII are described.


1999 ◽  
Vol 81 (02) ◽  
pp. 234-239 ◽  
Author(s):  
Sheila Connelly ◽  
Julie Andrews ◽  
Angela Gallo-Penn ◽  
Luigina Tagliavacca ◽  
Randal Kaufman ◽  
...  

SummaryAdenoviral vectors provide a promising gene therapy system for the treatment of hemophilia A. Potent vectors encoding a human factor VIII (FVIII) cDNA were developed that mediated sustained FVIII expression in normal and hemophiliac mice and complete phenotypic correction of the bleeding disorder in hemophiliac mice and dogs (Connelly and Kaleko, Haemophilia 1998; 4: 380-8). However, these studies utilized vectors encoding a truncated version of the human FVIII cDNA lacking the B-domain (BDD FVIII). In this work, an adenoviral vector encoding the human full-length (FL) FVIII cDNA was generated and characterized. While functional FL FVIII was secreted in vitro, expression of the FL protein was not detected in the plasma of vector-treated hemophiliac mice. Unexpectedly, the FL FVIII vector-treated animals demonstrated phenotypic correction of the bleeding defect as measured by a tail-clip survival study. FL FVIII protein was visualized in the mouse livers using human FVIII-specific immunohistochemical analyses. These data demonstrate that adenoviral vector-mediated in vivo expression of BDD FVIII is more efficient than that of the FL protein and that phenotypic correction can occur in the absence of detectable levels of FVIII.


Blood ◽  
1984 ◽  
Vol 63 (1) ◽  
pp. 31-41 ◽  
Author(s):  
PB Kernoff ◽  
ND Thomas ◽  
PA Lilley ◽  
KB Matthews ◽  
E Goldman ◽  
...  

Abstract Circulating antibodies to factor VIII (anti-VIII, “inhibitors”) occurring in patients with hemophilia neutralize porcine factor VIII less readily than human factor VIII in vitro. Over an 18-mo period, 8 patients with anti-VIII were treated with 45 courses (297 infusions) of polyelectrolyte-fractionated porcine factor VIII concentrate (PE porcine VIII). Where no anti-PE porcine VIII was detectable, mean post- infusion rise in plasma factor VIII was 1.29 U/dl/units infused/kg. Above 13 Old Oxford units of anti-PE porcine VIII and 48 Bethesda units of anti-human VIII, there were no postinfusion rises in plasma factor VIII. Where postinfusion rises were detected, clinical responses were good and conventional methods could be used to guide dosage. Ten percent of infusions were followed by febrile reactions, but these were usually mild and decreased in frequency and severity with increasing exposure. Multiple and prolonged courses of therapy were given to some patients without evidence of loss of clinical or laboratory efficacy. PE porcine VIII could provoke anamnestic rises of anti-VIII in susceptible patients, but appeared to have a lower immunogenic potential than human VIII. PE porcine VIII is a rational and effective therapeutic alternative for patients with anti-VIII, particularly those with intermediate level inhibitors who cannot be managed effectively using human factor VIII.


Sign in / Sign up

Export Citation Format

Share Document