scholarly journals Volar Plating: Imaging Modalities for the Detection of Screw Penetration

2019 ◽  
Vol 08 (06) ◽  
pp. 520-530
Author(s):  
Minke Bergsma ◽  
Katharina Denk ◽  
Job N. Doornberg ◽  
Michel P. J. van den Bekerom ◽  
Gino M. M. J. Kerkhoffs ◽  
...  

Abstract Background Volar plating for distal radius fractures exposes the risk of extensor tendon rupture, mechanical problems, and osteoarthritis due to protruding screws. Purposes The purpose of this review was to identify the best intraoperative diagnostic imaging modality to identify dorsal and intra-articular protruding screws in volar plating for distal radius fractures. Methods The Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were followed for this review. In vitro and in vivo studies that analyzed the reliability, efficacy, and/or accuracy of intraoperatively available imaging modalities for the detection of dorsal or intra-articular screw protrusion after volar plating for distal radius fractures were included. Results Described additional imaging modalities are additional fluoroscopic views (pronated views, dorsal tangential view [DTV], radial groove view [RGV], and carpal shoot through [CST] view), three-dimensional (3D) and rotational fluoroscopies, and ultrasound (US). For detection of dorsal screw penetration, additional fluoroscopic views show better results than conventional views. Based on small (pilot) studies, US seems to be promising. For intra-articular screw placement, 3D or 360 degrees fluoroscopy shows better result than conventional views. Conclusion Based on this systematic review, the authors recommend the use of at least one of the following additional imaging modalities to prevent dorsal protruding screws: CST view, DTV, or RGV. Tilt views are recommended for intra-articular assessment. Of all additional fluoroscopic views, the DTV is most studied and proves to be practical and time efficient, with higher efficacy, accuracy, and reliability compared with conventional views. Level of Evidence The level of evidence is Level III.

2017 ◽  
Vol 43 (2) ◽  
pp. 142-147 ◽  
Author(s):  
Daniel Martinez-Mendez ◽  
Alejandro Lizaur-Utrilla ◽  
Joaquin de-Juan-Herrero

We compared outcomes in elderly patients with intra-articular distal radius fractures treated by closed reduction and plaster immobilization or open reduction and internal fixation with a volar plate. Ninety-seven patients older than 60 years were randomly allocated to conservative (47 patients) or surgical (50 patients) treatment. Over a 2-year period, we assessed patient-rated wrist evaluation score, DASH (disability arm, shoulder and hand) questionnaire, pain, wrist range of motion, grip strength, and radiological parameters. The functional outcomes and quality of life were significantly better after volar plating fixation compared with conservative treatment. We found that restoration of the articular surface, radial inclination, and ulnar variance affected the outcomes, but the articular step-off did not. Twenty-five per cent of the patients with conservative treatment had secondary loss of reduction. We conclude that surgical plating leads to better outcomes than conservative treatment for elderly patients with intra-articular distal radius fractures. Level of evidence: I


Author(s):  
Jasper Prijs ◽  
Bram Schoolmeesters ◽  
Denise Eygendaal ◽  
Jean-Paul P. M. de Vries ◽  
Paul C. Jutte ◽  
...  

Abstract Purpose To evaluate the effect of three-dimensional virtual pre-operative planning (3DVP) on the incidence of dorsal screw penetration after volar plating of distal radius fractures. Methods A cross-sectional diagnostic imaging study was performed. Twenty out of 50 patients were randomly selected from our index prospective cohort (IPC): a prior study evaluating dorsal tangential views (DTVs) in reducing dorsal screw penetration in internal fixation of intra-articular distal radius fractures using post-operative CT scans to quantify screw protrusion. Pre-operative CTs from this cohort were now used for 3DVP by three experienced orthopaedic trauma surgeons (supplementary video). 3DVP was compared with the corresponding post-operative CT for assessing screw lengths and incidence of dorsal penetration. The Wilcoxon Signed Ranks test was used to compare screw lengths and the Fishers’ exact for incidence of penetration. Results Three surgeons performed 3DVP for 20 distal radius fractures and virtually applied 60 volar plates and 273 screws. Median screw length was shorter in the 3DVP when compared to IPC: 18 mm (range, 12–22) versus 20 mm (range, 14–26) (p < 0.001). The number of penetrating screws was 5% (13/273 screws) in the 3DVP group compared to 11% (10/91 screws) in the IPC (p = 0.047). Corresponding to a reduction in incidence of at least one dorsally penetrating screw in 40% of patients in the IPC group, to 18% in the 3DVP group (p = 0.069). Conclusion Three-Dimensional Virtual Pre-Operative Planning (3DVP) may reduce the incidence of dorsally penetrating screws in patients treated with volar plating for intra-articular distal radius fractures. Level of evidence II, diagnostic imaging study.


2019 ◽  
Vol 08 (06) ◽  
pp. 482-488 ◽  
Author(s):  
Peter Kaiser ◽  
Hannes Gruber ◽  
Fanny Loth ◽  
Gernot Schmidle ◽  
Rohit Arora ◽  
...  

Abstract Background Volar locking plates with a central notch were designed to reduce the risk of flexor pollicis longus (FPL) tendon irritation after volar plating for distal radius fractures. Objective The purpose of this study was to evaluate the course of the FPL tendon after FPL-plate osteosynthesis to identify a plate position that avoids an impingement with the FPL tendon. Patients and Methods Nineteen patients treated with volar plating using an FPL plate for a distal radius fracture were evaluated. Transverse ultrasound images were used to assess whether the profile of the FPL tendon lied within the plate notch. The position of the FPL tendon on transverse ultrasound images was transferred onto postoperative dorsovolar X-ray images to define an FPL tendon corridor for a plate position not interfering with the FPL tendon. Results The FPL tendon was aligned inside the plate notch completely in three cases, partially in 11 cases, and missed the notch in five cases. An FPL corridor was defined at the level of the watershed line with all FPL tendons being completely (74%) or partially (26%) aligned inside that corridor. There was a moderate correlation between the plate notch being positioned inside this corridor and the FPL tendon being positioned inside the plate notch (r = 0.49; p = 0.033). Conclusion It seems advantageous to place the plate notch within a corridor parallel to the radial shaft between the ulnar edge of the scaphoid tubercle and the scapholunate interval for the FPL tendon protection. Level of Evidence This is Level IV study.


2015 ◽  
Vol 40 (1) ◽  
pp. 27-33 ◽  
Author(s):  
Alexander Brunner ◽  
Christin Siebert ◽  
Claudia Stieger ◽  
Alexander Kastius ◽  
Björn-Christian Link ◽  
...  

Injury ◽  
2018 ◽  
Vol 49 (10) ◽  
pp. 1810-1815 ◽  
Author(s):  
Minke Bergsma ◽  
Job N. Doornberg ◽  
Robin Duit ◽  
Aimane Saarig ◽  
David Worsley ◽  
...  

2017 ◽  
Vol 06 (04) ◽  
pp. 340-348 ◽  
Author(s):  
Soo Cha ◽  
Hyun Shin

Background We evaluated the detection for screw penetration on the dorsal cortex of the radius in serial oblique, dorsal tangential, and radial groove radiographic views in volar plating fixation. Materials and Methods Eight screw positions were set in each of the four cadaveric radii. Screw 1 was placed in the styloid subregion, whereas screws 2 and 3 were placed just proximal to the styloid and were defined for the radial region of the radius. Screws 4 (distal to the extensor pollicis longus [EPL] groove), 5 (the distal half of the groove), and 6 (the proximal half of the groove) were placed in the central region of the radius. Screws 7 (just medial to the groove) and 8 (sigmoid notch subregion) were positioned in the ulnar region of the radius. The screws were overlengthened by 1 and 2 mm and were evaluated in three radiographic views. Results Penetrations in the radial region were fully visible in supinated oblique views with 1- and 2-mm overlengthened screws. The penetration of screw 4 was clearly observable over a considerable range of views. However, the 1-mm penetration of screw 5 was not detectable at any angle of projection. Detection of the ulnar region screw was the most difficult among the three regions with oblique views. In the dorsal tangential view, the 1-mm penetration of screw 4 was not observed in any of the four radii, but the penetration of screw 5 was detectable in all the radii. The screws 2, 3, 5, 7, and 8 were readily detectable. The screw 4 was barely seen in the radial groove view, while the screws 5 and 6 were readily detectable. Conclusion/Clinical Relevance Appropriate combinations of these well-known radiological views are essential for the overall detection of penetrated screws during plating in distal radius fractures.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.