First Experiences with MANTA Vascular Closure Device in Minimally Invasive Valve Surgery

2020 ◽  
Author(s):  
A. El-Sayed Ahmad ◽  
S. Salamate ◽  
M. Amer ◽  
S. Sirat ◽  
Ö. Akhavuz ◽  
...  
Author(s):  
Ali El-Sayed Ahmad ◽  
Saad Salamate ◽  
Mohamed Amer ◽  
Sami Sirat ◽  
Nadejda Monsefi ◽  
...  

Abstract Background To more minimize the minimally invasive valve surgeries, percutaneous vascular access and closure has been used for the establishment of extracorporeal circulation. This study investigates early clinical outcomes of patients who received MANTA for femoral artery closure as first experiences in minimally invasive valve surgery. Methods Between January 2019 and July 2019, 103 consecutive patients (mean age: 58 ± 11 years) underwent video-assisted minimally invasive valve surgery through right anterior minithoracotomy at two cardiac surgery referral centers in Germany. Percutaneous cannulation for cardiopulmonary bypass and femoral artery closure with MANTA were performed in all patients: 18-F and 14-F MANTA were used in 88 (85.4%) and 15 (14.6%) patient, respectively. Mitral, aortic, tricuspid, and double valve surgeries were performed in 51 (49.5%), 39 (37.9%), 7 (6.8%), and 6 (5.8%), patients, respectively. Clinical data were prospectively entered into our institutional database. Results Cardiopulmonary bypass time and cross-clamping time were 69 ± 23 and 38 ± 14 minutes, respectively. Except for two patients with late pseudoaneurysm on 15th and 23th postoperative day, neither major nor minor vascular complications nor vascular closure device failure according to the Valve Academic Research Consortium-2 definition criteria was observed. Additionally, no wound healing disorders or conversion to surgical closure was observed. Conclusions MANTA as percutaneous femoral artery closure after decannulation of cardiopulmonary bypass is a safe, feasible, and effective approach and yields excellent early outcomes. Larger size studies are needed to evaluate more the efficacy and safety of MANTA.


2021 ◽  
Vol 8 ◽  
Author(s):  
Andreas Schaefer ◽  
Harun Sarwari ◽  
Hermann Reichenspurner ◽  
Lenard Conradi

Objectives: Surgical exposure of groin vessels to establish cardiopulmonary bypass (CPB) for minimally-invasive valve surgery (MIS) is standard of care but may result in postoperative wound healing disorders or seroma formation. Therefore, adaption of transcatheter techniques for fully percutaneous insertion of CPB cannulae may improve clinical results. We herein analyze a single center experience with a novel plug-based vascular closure device for MIS.Methods: Between 03/2020 and 02/2021 MIS using the MANTA™ (Teleflex Medical Inc., Wayne, PA, USA) vascular closure device was performed in 28 consecutive patients (58.8 ± 10.6 years, 60.3% male, logEuroSCORE II 1.1 ± 0.8%) receiving mitral and/or tricuspid valve repair/replacement. Concomitant procedures were left atrial appendage occlusion and cryoablation for atrial fibrillation in 21.4% (6/28) and 10.7% (3/28) of patients, respectively. Data were retrospectively analyzed in accordance with standardized M-VARC definitions. MANTA™ device success and early safety was defined as absence of any access site or access related vascular injury and major and life-threatening bleeding complications.Results: MANTA™ device success with immediate hemostasis and early safety were 96.4% (27/28). In one case, device failure necessitated surgical cut down without further complications. Mean aortic cross clamp time and cardiopulmonary bypass were 96.5 ± 24.2 min and 150.2 ± 33.6 min. Stroke, renal failure or myocardial infarction were not observed. Intensive care unit and total hospital stay were 1.7 ± 0.8 days and 10.1 ± 5.7 days. Overall 30-day mortality was 0%. Post-procedure echocardiography presented one case of residual moderate tricuspid regurgitation and competent valves in all other cases.Conclusions: The MANTA™ device is safe and effective in MIS. Its ease of use and effectiveness to achieve immediate hemostasis have further simplified MIS.


2020 ◽  
Vol 110 (1) ◽  
pp. 85-91 ◽  
Author(s):  
Mikael Kastengren ◽  
Peter Svenarud ◽  
Göran Källner ◽  
Magnus Settergren ◽  
Anders Franco-Cereceda ◽  
...  

2017 ◽  
Vol 9 (S7) ◽  
pp. S614-S623 ◽  
Author(s):  
Orlando Santana ◽  
Steve Xydas ◽  
Roy F. Williams ◽  
S. Howard Wittels ◽  
Evin Yucel ◽  
...  

2020 ◽  

Minimally invasive cardiac surgery such as a mitral valve procedure requires femoral arterial cannulation for extracorporeal circulation. To avoid complications associated with surgical groin incisions, such as seromas and infections, percutaneous cannulation techniques can be used. This video tutorial illustrates percutaneous femoral cannulation and decannulation using a plug-based vascular closure device.


Sign in / Sign up

Export Citation Format

Share Document