The Accuracy and Ability of Preoperative Templating to Restore Femoral Offset in Calcar-Guided Short-Stem Total Hip Prosthesis through Direct Anterior Approach

Author(s):  
Barbara Favier ◽  
Nathalie van Beek ◽  
Mike Tengrootenhuysen

AbstractThe aim of this study was to assess the applicability and ability of preoperative templating to restore femoral offset and hip length with a calcar-guided short-stem implant design in total hip arthroplasty through the direct anterior approach. Preoperative measurements were performed of femoral offset, hip length, and stem size and compared with the perioperative placed prosthesis in 100 patients undergoing primary total hip replacement through direct anterior approach. Additionally, the pre- and postoperative femoral offset and hip length were compared to evaluate the ability to restore the offset and hip length with this kind of femoral short stem. With an acceptance of 1 size difference pre- and postoperatively, a 94% accuracy of predicting the size of the calcar-guided short stem was achieved with templating. Femoral offset was within means of 5 mm in 82.2% of the patients. Postoperative hip length was within 6 mm in 90% of the patients compared with the preoperative length.The use of preoperative templating for total hip arthroplasty with calcar-guided short-stem implants was proven to be a useful tool to predict the definite implanted size of the femoral prosthesis. Our results show that this new stem design does not significantly differ from previous reported outcomes with other stem designs and is competent to restore the femoral offset and hip length within clinical acceptable range. Level of evidence Level 3 retrospective case study.

2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.


2021 ◽  
Vol 10 (2) ◽  
pp. e575-e580
Author(s):  
David R. Maldonado ◽  
Samantha C. Diulus ◽  
Mitchell B. Meghpara ◽  
Rachel M. Glein ◽  
Hari K. Ankem ◽  
...  

2015 ◽  
Vol 9 (1) ◽  
pp. 157-162 ◽  
Author(s):  
Sachiyuki Tsukada ◽  
Motohiro Wakui

Objective: The aim of the study was to compare the dislocation rate between total hip arthroplasty (THA) via direct anterior approach (DAA) and via posterior approach (PA). Methods: We compared a consecutive series of 139 THAs via DAA with 177 THAs via PA. All study patients received ceramic-on-ceramic bearing surfaces and similar uncemented prostheses. Dislocation-free survival after THA was estimated using the Kaplan–Meier survival method and compared between groups using the log-rank test. Results: In the DAA group, none of 139 hips experienced dislocations in five-year-average follow-up. In the PA group, seven hips experienced dislocations among 177 hips (4 %). The dislocation was significantly less in the DAA group compared to the PA group (p = 0.033). Conclusion: The dislocation rate of THA via DAA was significantly less than that of THA via PA.


Sign in / Sign up

Export Citation Format

Share Document