Ligament Balancing and Constraint in Revision Total Knee Arthroplasty

Author(s):  
David A. Crawford ◽  
Adolph V. Lombardi

AbstractLigament balancing in revision knee arthroplasty is crucial to the success of the procedure. The medial collateral ligament and lateral ligament complex are the primary ligamentous structures that provide stability. Revisions can be performed with nonconstrained cruciate-retaining, posterior cruciate substituting, or anterior-stabilized/ultracongruent inserts when there are symmetrical flexion/extension gaps and intact collateral ligaments. When the collateral ligaments are insufficient either due to attenuation or incompetence from bone loss, a more constrained knee system is needed. Constrained condylar knees provide increased stability to both varus/valgus and rotation forces with a nonlinked construct. This increased constraint, however, does lead to increased stress at the implant–bone interface which requires more robust metaphyseal fixation. In cases of significant soft tissue disruption, severe flexion/extension gap mismatch or extensor mechanism disruption, a rotating hinge knee is needed to restore stability. Advances in revision implant design have led to improved outcomes and longer survivorship then earlier iterations of these implants. Surgeons should always strive to use the least constraint needed to achieve stability but must have a low threshold to increase constraint when ligament integrity is compromised.

2021 ◽  
Vol 87 (3) ◽  
pp. 449-451
Author(s):  
Lucas Petitqueux ◽  
Karen Verhulst ◽  
Jan Dauwe ◽  
Dirk Dauwe

Rotating-hinge knee implants are fully constrained knee prostheses commonly used for revision total knee arthroplasty. Nevertheless, rotating-hinge devices have been increasingly utilized in primary setting. Complications are inevitable in orthopedic surgery, however, implant breakage after RHK arthroplasty has been rarely described in medical literature. We present a rare case of 70-year-old Caucasian, male patient who suffered an atraumatic femoral stem breakage in a primary NexGen ® Rotating Hinge Knee (Zimmer-Biomet ® , Warsaw, IN, USA).


The Knee ◽  
2021 ◽  
Vol 28 ◽  
pp. 72-80
Author(s):  
Warran Wignadasan ◽  
Justin S. Chang ◽  
Babar Kayani ◽  
Christina Kontoghiorghe ◽  
Fares S. Haddad

2019 ◽  
Vol 4 (6) ◽  
pp. 269-278 ◽  
Author(s):  
Gilles Pasquier ◽  
Matthieu Ehlinger ◽  
Didier Mainard

Hinged implants are the most constrained knee replacement prostheses. They are very useful in complex cases of total knee arthroplasty (TKA) revision. Hinged implants have evolved with rotating bearings and modularity that allows local joint reconstruction or segmental bone replacement. They are required when significant instability persists in cases with inadequate collateral ligaments and significant flexion laxity. They are now used when a large bone defect is reconstructed, or when bone fixation of the implant is questionable especially in the metaphyseal zone. The use of hinged implants in TKA revision is associated with high complication rates. Published outcomes differ based on the patients’ aetiology. The outcomes of rotating-hinged implants used in septic revisions or salvage situations are poorer than other types of revision and have a higher complication rate. The poor general health of these patients is often a limitation. Despite these relatively poor results, hinged implants continue to have a place in revision surgery to solve major instability or to obtain stable bone fixation of an implant when the metaphysis is filled with bone grafts or porous devices.Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180070


2019 ◽  
Vol 34 (7) ◽  
pp. S271-S276 ◽  
Author(s):  
Joshua S. Bingham ◽  
Brandon R. Bukowski ◽  
Cody C. Wyles ◽  
Ayoosh Pareek ◽  
Daniel J. Berry ◽  
...  

PLoS ONE ◽  
2019 ◽  
Vol 14 (4) ◽  
pp. e0216004
Author(s):  
Jung-Ro Yoon ◽  
Ji-Young Cheong ◽  
Jung-Taek Im ◽  
Phil-Sun Park ◽  
Jae-Ok Park ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document