Collapse Resistance of RC Moment-Resisting Frame and Shear Wall Structural Systems Exposed to Blast

2017 ◽  
Vol 31 (2) ◽  
pp. 04016099
Author(s):  
Alaa I. Chehab ◽  
Christopher D. Eamon ◽  
Joshua Griffin
Author(s):  
Ahmad Sheikh Abdallah ◽  
Safwan Chahal

The rapid growth of urban population and limited land space have greatly influenced the development of high-rise structures. Lateral loads have an important effect on the design as the building height increases. In order to resist lateral loads, safety and minimum damage should be the prime concern when designing tall buildings. To meet these requirements, the structure should have adequate lateral strength and lateral stiffness and sufficient ductility. Among the various structural systems, shear wall systems or moment resisting frame systems could be a point of choice for designers. Thus, it is important to review and observe the behavior of these systems under seismic effect. This study compared the seismic response of the above structural systems using a case study application at variable seismic zones (Zone 2B, Lebanon Zone, Zone 3, and Zone 4) and at different building stories (Eight and 12-story building). The seismic response is measured in term of time-period, maximum story displacement, maximum story drift, amount of steel and concrete needed. The outcome of this study portrayed that a shear wall system is more efficient in terms of cost and lateral load resistivity regardless of the building height and in the four seismic zones mentioned before.


2019 ◽  
Vol 15 (8) ◽  
pp. 155014771985756 ◽  
Author(s):  
Mehdi Firoozbakht ◽  
Hamidreza Vosoughifar ◽  
Alireza Ghari Ghoran

The coverage intensity of sensors is the most important issue on structural health monitoring technique. The geometric configuration of sensors must be optimized based on coverage intensity with proper objectives. In this article, a novel algorithm for optimal sensor placement in various steel frames was evaluated. These frames including moment-resisting frame, moment-resisting frame with base isolation, and moment-resisting frame with base isolation with steel shear wall were selected for case studies. This approach was proposed based on combination of common optimal sensor placement algorithm and nonlinear time history analysis. A new method called transformed time history to frequency domain approach was evaluated to transform nonlinear time history analysis results to frequency domain and then the effective frequencies according the maximum range of Fourier amplitude were selected. The modified type of modal assurance criterion values can be achieved from modal assurance criterion with the exact seismic displacement. All of novel optimal sensor placement processes were done through FEM-MAC-TTFD code modeled and developed in MATLAB by authors of this article. The results show that there is good relative correlation between the sensors number and coverage intensity obtained with modal and modified modal assurance criterion approaches for moment-resisting frame system, but for integrated frame such as moment-resisting frame with base isolation and moment-resisting frame with base isolation with steel shear wall, the modified modal assurance criterion approach is better approach. There is no significant difference between coverage intensity of sensors for top joints between modal assurance criterion and modified modal assurance criterion approaches for moment-resisting frame, moment-resisting frame with base isolation, and moment-resisting frame with base isolation with steel shear wall systems ( R2 = 0.994, 0.986, and 0.724, respectively). It was found that if reference point is located in center of frame, there is significant difference between modal assurance criterion and modified modal assurance criterion approaches, and modified modal assurance criterion generated slightly better results.


Teras Jurnal ◽  
2018 ◽  
Vol 7 (2) ◽  
pp. 263
Author(s):  
Mul Muliadi Adi ◽  
M. Kabir Kabir Ihsan

Bangunan yang hancur oleh gempa dapat dicegah dengan memperkuat struktur bangunan terhadap gaya gempa yang bekerja padanya. Perkuatan bangunan dapat dilakukan dengan memperkaku bangunan dalam arah lateral yaitu <em>moment resisting frame</em> (<em>rigid frame</em>), <em>braced frame</em> dan <em>shear wall</em>. Bangunan dinding geser merupakan salah satu jenis <em>bangunan</em> tahan gempa gedung beton bertulang menggunakan sistem rangka struktur yang dikombinasikan. Kinerja gedung akan bertambah dan menjadi optimal jika pola penempatan <em>dinding geser</em> serta metode analisanya tepat. Sistem lainnya dalam mengurangi kerusakan bangunan akibat gempa dengan <em>performance based seismic design</em> yaitu dengan menggunakan <em>base isolator.</em>, yang memanfaatkan teknik analisa non-linear berbasis komputer untuk menganalisa perilaku inelastis struktur dari berbagai macam intensitas gerakan tanah (<em>gempa</em>), sehingga dapat diketahui kinerjanya pada kondisi kritis. Tujuan penelitian ini dilakukan untuk mengetahui perioda dalam penggunaan <em>base isolator </em>dengan yang tanpa menggunakan <em>base isolator,</em> pada bangunan sistem ganda, lantai 10 tingkat, bentuk beraturan pada bangunan dinding geser. Analisis data yang dilakukan dengan menggunakan bantuan <em>software </em>komputer <em>SAP2000</em>. Pembebanan pada gedung didasarkan pada peraturan bangunan gedung beton bertulang dan analisa dinamik <em>Time History Modal Analysi</em>s struktur dalam Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non Gedung (SNI 1726:2012). Dari hasil penelitian ini dapat diketahui bahwa penggunaan <em>base isolator</em> memperbesar perioda alami. Nilai perioda pada dinding geser dan dinding geser <em>base isolator</em> besarnya berturut-turut 0.988 detik dan 2.465 detik. Hal ini menyebabkan gaya gempa yang bekerja menjadi lebih kecil.