scholarly journals Study of lower hybrid current drive towards long-pulse operation with high performance in EAST

2015 ◽  
Author(s):  
2017 ◽  
Vol 157 ◽  
pp. 03011 ◽  
Author(s):  
Annika Ekedahl ◽  
Bojiang Ding ◽  
Xianzu Gong ◽  
Marc Goniche ◽  
Miaohui Li ◽  
...  

2012 ◽  
Vol 7 (0) ◽  
pp. 2502140-2502140 ◽  
Author(s):  
Gia Tuong HOANG ◽  
Léna DELPECH ◽  
Annika EKEDAHL ◽  
Young-soon BAE ◽  
Joelle ACHARD ◽  
...  

2011 ◽  
Vol 86 (6-8) ◽  
pp. 490-496 ◽  
Author(s):  
A. Bécoulet ◽  
G.T. Hoang ◽  
J.F. Artaud ◽  
Y.S. Bae ◽  
J. Belo ◽  
...  

2021 ◽  
Author(s):  
P K Sharma ◽  
D Raju ◽  
Surya Kumar Pathak ◽  
R Srinivasan ◽  
Kiran Ambulkar ◽  
...  

Abstract The steadystate superconducting tokamak (SST1) is aimed to demonstrate long pulse plasma discharges employing non-inductive current drive by means of lower hybrid current drive (LHCD) system. The major and minor radius of the machine is 1.1m and 0.2m respectively. The LHCD system for SST1 comprises of klystrons, each rated for 0.5MW-CW rf power at a frequency of 3.7 GHz. The grill antenna comprises of two rows, each row accommodating 32 waveguide elements. Electron cyclotron resonance (ECR) breakdown assisted Ohmic plasma is formed in SST1 to overcome the issues associated with low loop voltage start-ups. With recent modifications in the poloidal coils configuration, even with narrow EC pulse (~50ms), good repeatable and consistent Ohmic plasmas could be produced which helped in carrying out LHCD current drive experiments on SST1. These experiments demonstrated both fully as well as partially driven non-inductive plasma current in SST1 tokamak. Discharges with zero loop voltages were obtained. The interaction of lower hybrid waves with plasma and generation of suprathermal electrons could be established using energy spectra measured by CdTe detectors. Various other signatures like drop in loop voltages, negative loop voltages, spikes in hard x-rays and increase in 2nd harmonic ECE signal, further confirmed the current drive by LHW’s. The beneficial effect of LHW’s in suppressing hard x-rays was also demonstrated in these experiments. The non-inductive current drive in SST1 could also be established by modulating LH power. The longest discharge of ~650ms could be obtained in SST1 with the help of LHW’s. In this paper, the experimental results obtained with LHCD experiments on SST1 is reported and discussed in more details.


2014 ◽  
Vol 21 (6) ◽  
pp. 062510 ◽  
Author(s):  
M. H. Li ◽  
B. J. Ding ◽  
J. Z. Zhang ◽  
K. F. Gan ◽  
H. Q. Wang ◽  
...  

2005 ◽  
Vol 74 (1-4) ◽  
pp. 495-499 ◽  
Author(s):  
M. Grimes ◽  
D. Terry ◽  
R. Parker ◽  
D. Beals ◽  
J. Irby ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document