scholarly journals X-ray Computed Tomography of Structures in Opalinus Clay from Large Scale to Small Scale after Mechanical Testing

2016 ◽  
Vol 2016 (1) ◽  
pp. 1-3
Author(s):  
Gerhard Zacher ◽  
Annette Kaufhold ◽  
Matthias Halisch
Solid Earth ◽  
2016 ◽  
Vol 7 (4) ◽  
pp. 1171-1183 ◽  
Author(s):  
Annette Kaufhold ◽  
Matthias Halisch ◽  
Gerhard Zacher ◽  
Stephan Kaufhold

Abstract. In the past years X-ray computed tomography (CT) has became more and more common for geoscientific applications and is used from the µm-scale (e.g. for investigations of microfossils or pore-scale structures) up to the dm-scale (full drill cores or soil columns). In this paper we present results from CT imaging and mineralogical investigations of an Opalinus Clay core on different scales and different regions of interest, emphasizing especially the 3-D evaluation and distribution of cracks and their impact on mechanical testing of such material. Enhanced knowledge of the testing behaviour of the Opalinus Clay is of great interest, especially since this material is considered for a long-term radioactive waste disposal and storage facility in Switzerland. Hence, results are compared regarding the mineral (i.e. phase) contrast resolution, the spatial resolution, and the overall scanning speed.With this extensive interdisciplinary scale-down approach it has been possible to characterize the general fracture propagation in comparison to mineralogical and textural features of the Opalinus Clay. Additionally, and as far as we know, a so-called mylonitic zone, located at an intersect of two main fractures, has been observed for the first time for an experimentally deformed Opalinus sample. The multi-scale results are in good accordance to data from naturally deformed Opalinus Clay samples, which enables us to perform systematical research under controlled laboratory conditions. Accompanying 3-D imaging greatly enhances the capability of data interpretation and assessment of such a material.


2016 ◽  
Author(s):  
Annette Kaufhold ◽  
Gerhard Zacher ◽  
Matthias Halisch ◽  
Stephan Kaufhold

Abstract. In the past years X-ray Computed Tomography (CT) has became more and more common for geoscientific applications and is used from the µm-scale (e.g. for investigations of micro-fossils or pore scale structures) up to the dm-scale (full drill cores or soil columns). In this paper we present results from CT imaging and mineralogical investigations of an Opalinus Clay core on different scales and different regions of interest, emphasizing especially upon the 3D evaluation and distribution of cracks and their impact upon mechanical testing of such material. Enhanced knowledge of the testing behavior of the Opalinus Clay is of great interest, especially since this material is considered for a long term radioactive waste disposal and storage facility in Switzerland. Hence, results are compared regarding the mineral (i.e. phase) contrast resolution, the spatial resolution, and the overall scanning speed. With this extensive interdisciplinary top-down approach it has been possible to characterize the general fracture propagation in comparison to mineralogical and textural features of the Opalinus Clay. Additionally, and as far as we know, a so called mylonitic zone, located at the intersect of two main fractures, has been observed for the first time for an experimentally deformed Opalinus sample. The multi-scale results are in good accordance to data from naturally deformed Opalinus Clay samples, which enables to perform systematical research under controlled laboratory conditions. Accompanying 3D imaging greatly enhances the capability of data interpretation and assessment of such a material.


2015 ◽  
Vol 2015 (1) ◽  
pp. 1-2
Author(s):  
Gerhard Zacher ◽  
Thomas Paul ◽  
Annette Kaufhold ◽  
Werner Grasle

2021 ◽  
pp. 102070
Author(s):  
Grzegorz Ziółkowski ◽  
Konrad Gruber ◽  
Emilia Tokarczyk ◽  
Robert Roszak ◽  
Matthias Ziegenhorn

Author(s):  
J. S. Jørgensen ◽  
E. Y. Sidky

We introduce phase-diagram analysis, a standard tool in compressed sensing (CS), to the X-ray computed tomography (CT) community as a systematic method for determining how few projections suffice for accurate sparsity-regularized reconstruction. In CS, a phase diagram is a convenient way to study and express certain theoretical relations between sparsity and sufficient sampling. We adapt phase-diagram analysis for empirical use in X-ray CT for which the same theoretical results do not hold. We demonstrate in three case studies the potential of phase-diagram analysis for providing quantitative answers to questions of undersampling. First, we demonstrate that there are cases where X-ray CT empirically performs comparably with a near-optimal CS strategy, namely taking measurements with Gaussian sensing matrices. Second, we show that, in contrast to what might have been anticipated, taking randomized CT measurements does not lead to improved performance compared with standard structured sampling patterns. Finally, we show preliminary results of how well phase-diagram analysis can predict the sufficient number of projections for accurately reconstructing a large-scale image of a given sparsity by means of total-variation regularization.


2011 ◽  
Vol 23 (42) ◽  
pp. 4886-4891 ◽  
Author(s):  
Kelong Ai ◽  
Yanlan Liu ◽  
Jianhua Liu ◽  
Qinghai Yuan ◽  
Yangyang He ◽  
...  

2014 ◽  
Vol 42 (5) ◽  
pp. 20130247 ◽  
Author(s):  
Chichun Hu ◽  
Xiaoning Zhang ◽  
Yuhong Wang

Sign in / Sign up

Export Citation Format

Share Document