scholarly journals A New Absolute Method of Hygrometry. II. The Properties of Potassium Chloride Crystal Elements

1957 ◽  
Vol 10 (4) ◽  
pp. 429 ◽  
Author(s):  
RG Wylie

A new type of hygrometer, which has been termed the electrolytic condensation hygrometer, was described in the first of the present two papers. Its capabilities and limitations depend mainly on the characteristics of the conducting liquid layer formed on the surface of the crystal element used ; these characteristics depend in turn on those of the surface of the crystal.

1987 ◽  
Vol 61 (5) ◽  
pp. 325-331 ◽  
Author(s):  
Marie May ◽  
Edouard Rzepka ◽  
Solange Debrus ◽  
J.P. Hong

Nanomaterials ◽  
2020 ◽  
Vol 10 (10) ◽  
pp. 1931
Author(s):  
Minh Nhat Dang ◽  
Minh Dang Nguyen ◽  
Nguyen Khac Hiep ◽  
Phan Ngoc Hong ◽  
In Hyung Baek ◽  
...  

We herein present an alternative geometry of nanostructured carbon cathode capable of obtaining a low turn-on field, and both stable and high current densities. This cathode geometry consisted of a micro-hollow array on planar carbon nanostructures engineered by femtosecond laser. The micro-hollow geometry provides a larger edge area for achieving a lower turn-on field of 0.70 V/µm, a sustainable current of approximately 2 mA (about 112 mA/cm2) at an applied field of less than 2 V/µm. The electric field in the vicinity of the hollow array (rim edge) is enhanced due to the edge effect, that is key to improving field emission performance. The edge effect of the micro-hollow cathode is confirmed by numerical calculation. This new type of nanostructured carbon cathode geometry can be promisingly applied for high intensity and compact electron sources.


2020 ◽  
Vol 24 (05n07) ◽  
pp. 929-937
Author(s):  
Ewa Jaworska ◽  
Fabrizio Caroleo ◽  
Corrado Di Natale ◽  
Krzysztof Maksymiuk ◽  
Roberto Paolesse ◽  
...  

We present here a new type of fluoride ion optode, constituted by a highly lipophilic PVDF porous membrane modified with a liquid receptor layer containing the emission-active Si corrole F[Formula: see text] selective ionophore. For the optimized composition of the receptor layer, in acidic solutions an increase of Si-corrole emission was observed by increasing fluoride ion concentration, a behavior different from most porphyrinoid-based optical sensors. An observed linear dependence of the Si corrole emission intensity (read at 635 nm) was within the range 10[Formula: see text] to 10[Formula: see text] M of fluoride ions.


The Analyst ◽  
2014 ◽  
Vol 139 (12) ◽  
pp. 3122-3126 ◽  
Author(s):  
Ying Zhou ◽  
Tianshu Zhou ◽  
Min Zhang ◽  
Guoyue Shi

A new type of rapid, sensitive, and selective fluorescence turn-on assay was developed for detection of histidine using a DNA–scaffolded silver nanocluster/Cu2+ ensemble (DNA–AgNC/Cu2+).


Sign in / Sign up

Export Citation Format

Share Document