Use of Time-Domain Reflectometry (TDR) to measure the water-content of sandy soils

Soil Research ◽  
1995 ◽  
Vol 33 (2) ◽  
pp. 265 ◽  
Author(s):  
PJ Gregory ◽  
R Poss ◽  
J Eastham ◽  
S Micin

We investigated the potential sources of error when using time domain reflectometry (TDR) to measure the water content of sandy soils and evaluated the technique as a means of measuring evaporation from columns of soil and changes in soil water storage beneath crops. Inaccurate depth location of the transmission lines or the development of a hole at the tip of the transmission lines introduced an error about 10 times larger than the errors associated with hardware and software. Calibration in two sandy soils gave a curve of similar shape to that found by others except for values of dielectric constant < 6 when measured values of water content were less than those expected. Daily evaporation from soil columns measured by weighing and with TDR showed large differences between the two techniques (up to 32%) but compensating errors over time allowed cumulative evaporation to be estimated with TDR to within 6.6% of that determined by weighing over a 162 h period. Under field conditions, the agreement between TDR and neutron probe measures of changes in soil water storage in the upper 0.3 m was good and generally within 10% over both 14 day and longer periods.


2000 ◽  
Vol 80 (1) ◽  
pp. 43-52 ◽  
Author(s):  
David R. Lapen ◽  
Jonathan S. Price ◽  
Robert Gilbert

Time domain reflectometry (TDR) was used to estimate soil water storage dynamics in several uncultivated blanket bogs and poor fens in southeastern Newfoundland during the summer growing season. The purpose of the research was to evaluate links between surface moisture conditions, evapotranspiration, and recharge processes in order to elucidate factors that govern blanket peat formation in the region. Water storage changes in the peat/Sphagnum above the water table (ΔSWS) were found to be important storage terms in daily water balance estimates. Daily mean ΔSWS values for bog and fen approximated −0.3 and −0.45 mm, respectively. It was also found that, i) fairly high peat water-holding capacities, ii) frequent atmospheric recharge, iii) atmospheric controls on evapotranspiration, and, iv) the transport of water into the unsaturated zone from the shallow water table via capillary and external wicking processes helped to preclude significant de-watering over the bulk of the peatland surfaces. Recharge via groundwater appears to be an important factor governing moisture conditions requisite for peat accrual and the growth of Sphagnum spp., especially in the fens. Key words: Time domain reflectometry, blanket peats, soil water, evapotranspiration, water table depth







Soil Science ◽  
2010 ◽  
Vol 175 (10) ◽  
pp. 469-473 ◽  
Author(s):  
Zhaoqiang Ju ◽  
Xiaona Liu ◽  
Tusheng Ren ◽  
Chunsheng Hu


2016 ◽  
Vol 13 (1) ◽  
pp. 63-75 ◽  
Author(s):  
K. Imukova ◽  
J. Ingwersen ◽  
M. Hevart ◽  
T. Streck

Abstract. The energy balance of eddy covariance (EC) flux data is typically not closed. The nature of the gap is usually not known, which hampers using EC data to parameterize and test models. In the present study we cross-checked the evapotranspiration data obtained with the EC method (ETEC) against ET rates measured with the soil water balance method (ETWB) at winter wheat stands in southwest Germany. During the growing seasons 2012 and 2013, we continuously measured, in a half-hourly resolution, latent heat (LE) and sensible (H) heat fluxes using the EC technique. Measured fluxes were adjusted with either the Bowen-ratio (BR), H or LE post-closure method. ETWB was estimated based on rainfall, seepage and soil water storage measurements. The soil water storage term was determined at sixteen locations within the footprint of an EC station, by measuring the soil water content down to a soil depth of 1.5 m. In the second year, the volumetric soil water content was additionally continuously measured in 15 min resolution in 10 cm intervals down to 90 cm depth with sixteen capacitance soil moisture sensors. During the 2012 growing season, the H post-closed LE flux data (ETEC =  3.4 ± 0.6 mm day−1) corresponded closest with the result of the WB method (3.3 ± 0.3 mm day−1). ETEC adjusted by the BR (4.1 ± 0.6 mm day−1) or LE (4.9 ± 0.9 mm day−1) post-closure method were higher than the ETWB by 24 and 48 %, respectively. In 2013, ETWB was in best agreement with ETEC adjusted with the H post-closure method during the periods with low amount of rain and seepage. During these periods the BR and LE post-closure methods overestimated ET by about 46 and 70 %, respectively. During a period with high and frequent rainfalls, ETWB was in-between ETEC adjusted by H and BR post-closure methods. We conclude that, at most observation periods on our site, LE is not a major component of the energy balance gap. Our results indicate that the energy balance gap is made up by other energy fluxes and unconsidered or biased energy storage terms.



Irriga ◽  
2018 ◽  
Vol 14 (4) ◽  
pp. 564-577 ◽  
Author(s):  
Leonardo Do Nascimento Lopes ◽  
Elton Martins ◽  
Bruno De Lima Santoro ◽  
Claudinei Fonseca Souza

CARACTERIZAÇÃO DA DISTRIBUIÇÃO DA ÁGUA NO SOLO PARA IRRIGAÇÃO POR GOTEJAMENTO  Leonardo do Nascimento Lopes1; Elton Martins2; Bruno de Lima Santoro2; Claudinei Fonseca Souza31Universidade de Taubaté, Unitau, Taubaté, SP,  [email protected] Engenharia Civil e Ambiental, Universidade de Taubaté, Taubaté, Unitau, SP 3Departamento de Recursos Naturais e Proteção Ambiental, Universidade Federal São Carlos, São Carlos, SP  1 RESUMO O conhecimento da distribuição da água no solo é de grande importância para a agricultura, uma vez que a água é um dos fatores que mais influenciam o rendimento das culturas. Existem muitas técnicas utilizadas para o monitoramento do conteúdo de água do solo, a reflectometria domínio do tempo (TDR) tem sido difundida entre os pesquisadores por apresentar várias vantagens, entre as quais a determinação em tempo real e a possibilidade de leituras automatizadas. O principal objetivo desta pesquisa foi avaliar a distribuição da água no perfil de um Latossolo Vermelho-Amarelo. Sondas de Reflectometria no domínio do Tempo (TDR) foram utilizadas para monitorar a distribuição de água no solo aplicada através de gotejadores de fluxo constante nas taxas de 2, 4 e 8 Lh-1. Considerando os resultados de diferentes perfis, observa-se um maior armazenamento da água próximo do gotejador diminuindo progressivamente para frente de molhamento. Aproximadamente, um terço da água aplicada (33%) foi armazenado na primeira camada (0-0,10 m) para todos os ensaios. Comparando diferentes taxas de aplicação, observa-se maior armazenamento de água para o gotejador de 8L h-1, com 30, 33 e 34% de água aplicada acumulada na primeira camada (0-0.10 m) para gotejadores de 2, 4 e 8L h-1, respectivamente. Os resultados sugerem que, com base no volume e frequência utilizada neste experimento, seria vantajoso aplicar pequenas quantidades de água em intervalos mais frequentes para reduzir perdas por percolação. UNITERMOS: TDR, conteúdo de água, bulbo molhado  LOPES, L. N.; MARTINS, E.; SANTORO, B. L.; SOUZA, C. F.WATER DISTRIBUTION CHARACTERIZATION IN SOIL FOR DRIP IRRIGATION   2 ABSTRACT Knowledge of water distribution in soil is of great importance to agriculture, since water is one of the factors that most influence the yield of crops. There are many techniques used to monitor soil water content. The time domain reflectometry (TDR) has been widespread among researchers because it presents several advantages, among which the determination in real time and possibility of automated readings. The main goal of this research was to evaluatethe water distribution in a profile of Red-Yellow Oxisol. Time domain reflectometry (TDR) probes were used to monitor the water distribution from drippers discharging at constant flow rates of 2, 4 and 8 Lh-1 in soil. Considering results from different profiles, we observed greater water storage near the dripper decreasing gradually towards the wetting front. About one third of the applied water (33%) was stored in the first layer (0-0.10 m) for all experiments. Comparing different dripper flow rates, we observed higher water storage for 8 L h-1, with 30, 33 and 34% of applied water accumulating in the first layer (0-0.10m) for dripper flow rates of 2, 4 and 8 L h-1, respectively. The results suggest that based on the volume and frequency used in this experiment, it would be advantageous to apply small amounts of water at more frequent intervals to reduce deep percolation losses of applied water. KEYWORDS: TDR, water content, wetted soil volume



Sign in / Sign up

Export Citation Format

Share Document