COMPARISON OF METHODS FOR THE CALCULATION OF LINE-TO-LINE SHORT CIRCUIT OF SYNCHRONOUS MACHINES AT LOW FREQUENCIES

1981 ◽  
Vol 6 (4) ◽  
pp. 287-295 ◽  
Author(s):  
J. P. CHASSANDE ◽  
M. POLOUJADOFF ◽  
A. A. ABDEL-RAZEK ◽  
A. LAUMOND
2005 ◽  
Vol 151 (3) ◽  
pp. 61-70 ◽  
Author(s):  
Takashi Kano ◽  
Shu Yamamoto ◽  
Takahiro Ara

2021 ◽  
Author(s):  
Frederic Maurer ◽  
Jonas Kristiansen Nøland

The sudden short-circuit is considered the gold-standard parameter measurement method for wound-field synchronous machines (WFSMs) as it enables the recording of the characteristic quantities in near-to-real conditions. However, the test needs huge pieces of equipment, but even worse, it reduces the lifetime of the electrical components by up to 10 years due to the high winding overhang mechanical forces. The DC-Decay tests are low-power alternatives to obtain the characteristic quantities without damaging the machinery. To allow wider use of this method, there are a couple of challenges left that are tackled by this paper. The two main open challenges are, firstly, the number of measurements needed to reach a particular precision, and secondly, a comparison of the DC-Decay with the sudden short-circuit test to allow the validation against the gold standard. More detailed, this paper explores the main challenges associated with the practical use of the DC decay method, which is a non-conventional and detailed-level approach to characterize WFSMs. We provide replies and recommendations regarding the number of measurements, suggesting the minimum number of recorded tests needed to obtain the equivalent diagram with a given accuracy, which has been further validated with an experimental case study. Moreover, the potential enhancement and precision of the parameter identification algorithm are studied in detail. Finally, the equivalent parameters of the DC decay method are compared to the gold standard, which concludes on what the characterization means in terms of predicting accurate transient short-circuit currents for WFSMs.


2021 ◽  
Author(s):  
Frederic Maurer ◽  
Jonas Kristiansen Nøland

The sudden short-circuit is considered the gold-standard parameter measurement method for wound-field synchronous machines (WFSMs) as it enables the recording of the characteristic quantities in near-to-real conditions. However, the test needs huge pieces of equipment, but even worse, it reduces the lifetime of the electrical components by up to 10 years due to the high winding overhang mechanical forces. The DC-Decay tests are low-power alternatives to obtain the characteristic quantities without damaging the machinery. To allow wider use of this method, there are a couple of challenges left that are tackled by this paper. The two main open challenges are, firstly, the number of measurements needed to reach a particular precision, and secondly, a comparison of the DC-Decay with the sudden short-circuit test to allow the validation against the gold standard. More detailed, this paper explores the main challenges associated with the practical use of the DC decay method, which is a non-conventional and detailed-level approach to characterize WFSMs. We provide replies and recommendations regarding the number of measurements, suggesting the minimum number of recorded tests needed to obtain the equivalent diagram with a given accuracy, which has been further validated with an experimental case study. Moreover, the potential enhancement and precision of the parameter identification algorithm are studied in detail. Finally, the equivalent parameters of the DC decay method are compared to the gold standard, which concludes on what the characterization means in terms of predicting accurate transient short-circuit currents for WFSMs.


Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2528
Author(s):  
Emilio Rebollo ◽  
Carlos A. Platero ◽  
David Talavera ◽  
Ricardo Granizo

The discharge resistor is only used in case of electrical trip to reduce the field current as fast as possible and to minimize the damages produced by the short-circuit current supplied by the synchronous machine. The connection of the discharge resistor is done by opening the field breaker and it implies a large negative voltage in the field winding. This negative voltage is limited to 80% of the winding insulation voltage. On the other hand, in case of a transient de-excitation, at the first moment, the automatic voltage regulator (AVR) reduces the field voltage to the minimum. In case of one-quadrant rectifier type AVR, the minimum voltage is zero and in case of two-quadrant rectifier AVR, the minimum voltage is close to the ceiling voltage with negative polarity. In both cases, the minimum voltages are much smaller than the negative voltage produced by the connection of the discharge resistor. This paper presents a new system that improves the transient de-excitation of synchronous machines using the discharge resistor by an additional static field breaker (SFB). The control of the static field breaker and consequently the connection and disconnection of the discharge resistor is done based on the output field voltage supplied by the AVR. This allows the exciter field current to be reduced in a faster way and continue with the normal operation of the machine after the transient. In this study, the correct operation of the additional static field breaker (SFB) has been validated by computer simulations and experimental test in a 15 MVA generator comprising a commercial one-quadrant rectifier AVR type obtaining excellent results.


Sign in / Sign up

Export Citation Format

Share Document