Contact force technology integrated with 3D navigation system for atrial fibrillation ablation: improving results?

2017 ◽  
Vol 14 (6) ◽  
pp. 461-467 ◽  
Author(s):  
Roberto Rordorf ◽  
Antonio Sanzo ◽  
Vincenzo Gionti
2020 ◽  
Vol 2 (1) ◽  
pp. e000058
Author(s):  
Joseph G Akar ◽  
James P Hummel ◽  
Xiaoxi Yao ◽  
Lindsey Sangaralingham ◽  
Sanket Dhruva ◽  
...  

ObjectivesContact force-sensing catheters allow real-time catheter-tissue contact force monitoring during atrial fibrillation. These catheters were rapidly adopted into clinical practice following market introduction in 2014, but concerns have been raised regarding collateral damage such as esophageal injury. We sought to examine whether the introduction of force-sensing catheters was associated with a change in short-term and intermediate-term acute care use, complications and mortality following atrial fibrillation ablation.DesignRetrospective cohort analysis. We used inverse probability treatment weight matching to account for the differences in baseline characteristics between groups.SettingWe examined patients included in the OptumLabs Data Warehouse who underwent ablation for atrial fibrillation before (2011–2013) and after (2015–2017) the market introduction of contact force-sensing catheters.Main outcome measuresWe examined 30-day and 90-day rates of all-cause acute care use, including hospitalizations and emergency department visits, as well as death and hospitalization for catheter-related complications, including atrioesophageal fistula, pericarditis, cardiac tamponade/perforation and stroke/transient ischemic attack.ResultsOur sample included 3470 and 5772 patients who underwent atrial fibrillation (AF) ablation before and after market introduction of contact force-sensing catheters, respectively. Complication rates were low and did not differ between the two periods (p>0.10 for each outcome). The 30-day and 90-day mortality was 0.1% and 0.3%, respectively after market introduction and unchanged from prior to 2014. The 90-day rates of all-cause acute care use decreased, from 27.0% in 2011–2013 to 23.9% in 2015–2017 (p<0.001).ConclusionsAF ablation-related catheter complications and mortality are low and there has been no significant change following the introduction of force-sensing catheters.


Author(s):  
Mohammed Shurrab ◽  
Luigi Di Biase ◽  
David F. Briceno ◽  
Anna Kaoutskaia ◽  
Saleem Haj‐Yahia ◽  
...  

2017 ◽  
Vol 70 (9) ◽  
pp. 706-712
Author(s):  
Gabriel Ballesteros ◽  
Pablo Ramos ◽  
Renzo Neglia ◽  
Diego Menéndez ◽  
Ignacio García-Bolao

EP Europace ◽  
2017 ◽  
Vol 19 (suppl_3) ◽  
pp. iii70-iii70
Author(s):  
C. Arantes ◽  
N. Cortez-Dias ◽  
J. Agostinho ◽  
IS. Goncalves ◽  
G. Lima Da Silva ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document