Application of a surface matching image registration technique to the correlation of cardiac studies in positron emission tomography (PET) by transmission images

1995 ◽  
Vol 40 (10) ◽  
pp. 1695-1708 ◽  
Author(s):  
S Pallotta ◽  
M C Gilardi ◽  
V Bettinardi ◽  
G Rizzo ◽  
C Landoni ◽  
...  
PLoS ONE ◽  
2014 ◽  
Vol 9 (1) ◽  
pp. e87167 ◽  
Author(s):  
Floris H. P. van Velden ◽  
Ida A. Nissen ◽  
Wendy Hayes ◽  
Linda M. Velasquez ◽  
Otto S. Hoekstra ◽  
...  

: Functional near infrared spectroscopy (fNIRS) is an imaging system that can measure hemodynamic changes of the brain. However, the system incapability to measure beyond the brain cortex region make it usage less appealing for in-depth brain studies. To overcome this, many researchers combine fNIRS with other imaging modalities to gain better understanding of the brain activities. In this paper, we described the theory of the registering fNIRS signals and positron emission tomography (PET) image method and performed experiments to validate it. The registration method was validated using specially designed phantom for fNIRS and PET. Polaris system was used to track the position of the phantom which is based on the Polaris markers during fNIRS and PET procedures. The Polaris markers share the same coordinate, thus the fNIRS and PET were calibrated to each other through these markers. To register the fNIRS signal on the PET image, the phantom position in fNIRS coordinate is translated to PET coordinate which allow the probe and the markers being coordinated in PET. Polaris markers were used as the references marker to determine the transformation matrices. The result shows that the fNIRS channel can be viewed on the PET image of the phantom. The transformation error from Polaris to PET is less than 1.00 mm and the precision test is less than 0.1mm while the accuracy is less than 2.8 mm. This result suggests that our theory on the registration method could be used for multimodal image registration between fNIRS and other modalities.


2020 ◽  
Vol 13 (4) ◽  
pp. 348-357
Author(s):  
Keisuke Matsubara ◽  
◽  
Masanobu Ibaraki ◽  
Miho Shidahara ◽  
Toshibumi Kinoshita

AbstractImprecise registration between positron emission tomography (PET) and anatomical magnetic resonance (MR) images is a critical source of error in MR imaging-guided partial volume correction (MR-PVC). Here, we propose a novel framework for image registration and partial volume correction, which we term PVC-optimized registration (PoR), to address imprecise registration. The PoR framework iterates PVC and registration between uncorrected PET and smoothed PV-corrected images to obtain precise registration. We applied PoR to the [11C]PiB PET data of 92 participants obtained from the Alzheimer’s Disease Neuroimaging Initiative database and compared the registration results, PV-corrected standardized uptake value (SUV) and its ratio to the cerebellum (SUVR), and intra-region coefficient of variation (CoV) between PoR and conventional registration. Significant differences in registration of as much as 2.74 mm and 3.02° were observed between the two methods (effect size <  − 0.8 or > 0.8), which resulted in considerable SUVR differences throughout the brain, reaching a maximal difference of 62.3% in the sensory motor cortex. Intra-region CoV was significantly reduced using the PoR throughout the brain. These results suggest that PoR reduces error as a result of imprecise registration in PVC and is a useful method for accurately quantifying the amyloid burden in PET.


Sign in / Sign up

Export Citation Format

Share Document