scholarly journals The Research of GIS Discharge Influence Based on Particle Properties in Installation Environment

2021 ◽  
Vol 2121 (1) ◽  
pp. 012040
Author(s):  
Leicheng Lin ◽  
Dan Chen

Abstract In order to explore the influence of atmospheric free particles that exit during GIS installation on the stable operation of GIS, the size, shape and inner properties of the particles contained in the air are analyzed. And based on 500kV GIS equipment, the GIS gas chamber model and the model of free particles were established. By using the finite element simulation software, the surface electric field distribution when the free particles remain on the insulator surface is solved. The results show that the electric field distribution of particles which exist along the surface of insulator is directly related to the relative permittivity of the material of the particles themselves, and the intensity of the electric field along the surface increases with the increase of the relative permittivity. with the fact that the relative permittivity of air particles is almost below 20, as a result, the existence of 10µm grade non-metallic free particles will not cause flashover discharge. But, when a small number of Fe3O4 particles which size over 1mm or when them accumulate regularly, it will lead to flashover discharge. Therefore, the suspended atmospheric particles in the installation environment have little impact on the stable operation of GIS. When considering the installation environmental conditions, the installation can be carried out on a clear, windless day which can save costs.

2012 ◽  
Vol 21 (7) ◽  
pp. 078502 ◽  
Author(s):  
Xia-Rong Hu ◽  
Bo Zhang ◽  
Xiao-Rong Luo ◽  
Yuan-Gang Wang ◽  
Tian-Fei Lei ◽  
...  

2014 ◽  
Vol 986-987 ◽  
pp. 299-302
Author(s):  
Ding Jun Wen ◽  
Xiu Bin Zhang ◽  
Hong Gang Chen ◽  
Feng Jiang ◽  
Ya Ming Sun

330kV transmission line in the northwest region of China is much complex while pollution flashover is a major threat to the safe operation of the system. In this paper, experimental study on effect of contamination on electric field distribution of 330kV composite insulator is presented. High voltage test system of 330kV composite insulator is established according to the ratio of 1:1. Surface electric field and potential of the insulator is measured using GDC-100 optical fiber voltage electric field measuring instrument. Potential, electric field distribution of the two kinds of 330kV composite insulator are tested in different environment of clean, dry and uniform pollution layer. The test and simulation result is also compared.


Sign in / Sign up

Export Citation Format

Share Document