scholarly journals Mechanical Properties and Energy Conservation Analysis for The New Connection of The Fabricated Shear Wall

2021 ◽  
Vol 804 (2) ◽  
pp. 022094
Author(s):  
Handuo Fan ◽  
Yueguo Zhang ◽  
Yichao Zhang ◽  
Haowen Jiang ◽  
Linghang Du ◽  
...  
2016 ◽  
Vol 22 (2) ◽  
pp. 129
Author(s):  
Yudhi Arnandha ◽  
Iman Satyarno ◽  
Ali Awaludin ◽  
Arfiati Fardhani

Wood Plastic Composite (WPC) is wood based material that been produce by mixing sawdust as main composition and plastic polymer as bonding agent. Nowadays, WPC board already been produced in Indonesia using Sengon sawdust and recycle HDPE plastic. Sengon sawdust was used as WPC since its availability from plywood production waste, moreover HDPE plastic considered had higher strength and more rigid than PET plastic. WPC occasionally being used as non structural material, moreover from previous study about mechanical properties of WPC, it was found that WPC Sengon has high shear strength around 25 – 30 MPa. These lead that WPC Sengon had a potential used as shear wall sheathing, thus additional research need to be conducted in order to study the type of bolt and diameter of the bolt can be used for these shear wall. This study aimed to investigate the dowel bearing of bolt using full hole method based on ASTM D5764 with type and bolt diameter as specimen variation. Two types of bolt were used in this study; stainless bolt and standard bolt with diameter each of 6 mm, 8 mm, 10 mm and 12 mm. According to ANOVA, there was insignificant result between stainless bolt and standard one, but there was significant result based on diameter of the bolt. Hereafter, it can be recommended the used of 10 mm diameter of bolt for structural purpose with dowel bearing strength around 67 – 70 MPa.


2014 ◽  
Vol 494-495 ◽  
pp. 1674-1677
Author(s):  
Bing Xu ◽  
Fang Hong Yuan ◽  
Bao Guo Zheng ◽  
Zhong Jin Shi ◽  
Yi Huan Hu

This article discusses energy conservation for air conditioning systems in rail transit stations. At first, the paper analyzes the energy consumption condition in the air conditioning systems in rail transit stations. Then, it discusses application of appropriate control strategy for reducing energy consumption. In the end, the paper calculates effiency and amount of the energy saving based on the control strategy.


2015 ◽  
Vol 1120-1121 ◽  
pp. 1516-1519
Author(s):  
Yong Song Shao ◽  
Feng Ru Shao

Due to mechanical performances of brace and steel plate, mechanical properties of semi-rigid joints and its construction and installation, semi-rigid steel frame-braced steel plate shear wall system is proposed. Nonlinear static analysis with parameters (thickness of plate, type of brace, size of brace and the ratio of span to height) changed of a single-span and single-floor semi-rigid steel frame-braced steel plate shear wall system illustrates that braced steel plate shear walls contributes obviously to bearing capacity and lateral rigidity of semi-rigid steel frame. Also, the finite element analysis (by ANSYS) show that semi-rigid steel frame-braced steel plate shear wall system has excellent ductility.